SMC Corporation of America
Elite Part Number Search
Search Results "CDRQ2BS30-90C-A93L"

L (Example) A93L 5m. Z (Example) F9NWZ Note) Solid state switches marked "" are produced upon receipt of order. Note) For cylinders with auto switches, the switches (already attached to mounting brackets) are packed together with the cylinder for shipment, but are not mounted on the cylinder.

L (Example) A93L 5m . Z (Example) F9NWZ Solid state auto switches with a "" symbol are produced upon receipt of order.

NPN) F9NV F9N 3 wire(NPN) Diagnostic indication (2 color) F9PV F9P 3 wire(PNP) P.5.3-39 F9BV F9B 2 wire Relay, PLC 24V Yes Grommet 12V F9NWV F9NW 3 wire(NPN) F9PWV F9PW P.5.3-66 3 wire(PNP) F9BWV F9BW 2 wire PLC: Programmable Logic Controller *Lead wire length 0.5m (Ex.) 3m L A93 A93L Specifications Specifications are same as the standard style.

A93 A93L F9NWZ (Example) (Example) (Example) 13 Rotary Table Series MSQ Specifications 10 20 30 50 70 100 200 Size Air (non-lube) Fluid Maximum operating pressure Minimum operating pressure 1MPa With adjustment bolt Note 1) 0.6MPa With internal shock absorber 0.1MPa Basic type 0.2MPa 0.1MPa High precision type 0 to 60C (with no condensation) Ambient and fluid temperature Rubber bumper With

L A93L Note) Refer to P. 177 to 179 for further information of auto switch. PLC: Programmable Logic Controller Specifications Specifications are same as the standard type.

Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ In addition to the models in the above table, there are some other auto switches that are applicable.

Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) M9NZ Refer to page 8-28-27 for additional details and applicable auto switches other than the above types.

pressure per 20 psig (0.14 MPa) source pressure drop Bottom mount 0.19 in3 (3.1 cm3) 0.99 lbs (0.45 kg) 3) Delivery pressure Gas Source pressure Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Inboard leakage Outboard leakage Leak rate Across the seat leak Surface finish Connections Supply pressure effect Installation Internal volume Mass 1) 14 to 194F (10 to 90C

The compatibility shown in the table is when the fluid temperature is within the product specification (90C or less). Chemical Note 1) Static electricity may be generated. Take measures to prevent static electricity. Note 2) Fluid may permeate through and affect parts made of other materials. 620

Specifications AP3260 Select compatible materials of construction for the gas Vacuum to 125 psig (0.9 MPa) 1000 psig (6.9 MPa) 8000 psig (55.2 MPa) 40 to 194F (40 to 90C) (No freezing) 0.27 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 1) 1 x 10-7 Pam3/sec 1) Ra max 15 in. (0.4 m) Option: 10 in. (0.25 m), 7 in. (0.18 m), 5 in. (0.13 m) Face seal, Tube weld Bottom mount (Option: panel mount) 0.06

(0.7 MPa) source pressure drop Bottom mount (Option: panel mount) 0.49 in3 (8 cm3) 2.76 lbs (1.25 kg) 5) Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Inboard leakage Outboard leakage Leak rate Across the seat leak Surface finish Connections Supply pressure effect Installation Internal volume Mass 1) Max 300 psig (2.1MPa) for PTFE seat. 2) 14 to 194F (10 to 90C

Circulating fluid at 20C) 9.5 (Circulating fluid at 20C) Operating temperature range C -30 to 90 -30 to 90 Temperature stability C 0.1*2 0.1*2 Circulating fluid flow display range*3 L/min 5 to 40 5 to 40 Circulating fluid flow setting range*4 L/min 10 to 40 10 to 40 Circulating fluid discharge pressure display range MPa 0 to 1.5 0 to 1.5 -30 to 40C: Galden HT135*5 FluorinertTM FC-3283*5 20 to 90C

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SWITCH,COMBO UNIT, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, 2.14500

Cooling capacity None Nil C D N Z Analog communication Symbol 001 002 004 008 Cooling capacity DeviceNet communication 1 kW NPT fittings 2 kW Temperature range setting Circulating fluid automatic recovery 4 kW Temperature range setting 1 kW 2 kW 4 kW 8 kW Symbol L H W 8 kW 20 to 40C 20 to 90C 20 to 90C Specifications (For details, please consult our Product Specifications information.)

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EA, IFW/PFW 3/8INCH PT VERSION, 2.08890

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SWITCH,COMBO UNIT, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, 2.40768

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EX, IFW/PFW 3/8INCH ALL OTHERS, 2.11643

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EX, IFW/PFW 3/8INCH ALL OTHERS, 2.20462

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EX, IFW/PFW 3/8INCH ALL OTHERS, 1.77719

Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, EB, IFW/PFW 3/8INCH NPT VERSION, 1.98416