SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2LC63TN-75DZ-D"

Magnet: None, Mounting: L (Foot), Type: Standard, Bore Size: 100mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 32mm, Port Thread Type: TF (G 32-100 Bore), Stroke: 75mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: L (Foot), Type: Standard, Bore Size: 100mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 75mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 100mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 75mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Magnet: D (Built-in), Mounting: G (Rear Flange), Type: Standard, Bore Size: 32mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 75mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: