Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Magnet: Built-in, Mounting: Foot, Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Mounting
Magnet: Built-in, Mounting: Foot, Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -, Mounting Threads:
SMC solves these limitations with our XB14 option, the markets original compact cylinder with the D-F7NJ heat resistant switch. Special seals and heat resistant grease allow this product to be placed on designs located in environments up to 300F, making high temperature environments no longer a restriction.
Indicator light Sensor section: 0 to 150C Amplifier section: 0 to 60C Precautions Caution Ambient temperature Sensor section: 1000 m/s2 Amplifier section: 300 m/s2 Impact resistance Auto switch which can be mounted on heat resistant, compact cylinder, CDQ2-XB14. For using for other cylinders, please confirm SMC.
40 50 63 CDQ2 Compact cylinder CDQ2-XB14 Double acting, Single rod Except with rubber bumper Series D-M9 J 15-E644
Yes, it is available using the special order part number suffix “-XB14.” The product is a combination of a heat-resistant CDQ2 series cylinder (bore sizes ø16 to ø63) and a heat-resistant auto switch for the CDQ2.
The “-XB14” uses an “-XB6” heat-resistant cylinder (with heat-resistant seal material and grease) with a built-in heat-resistant magnet (for CDQ2 series cylinders).
switch option (XB14) temperature range 0°F to 302°F
switch option (XB14) temperature range 0°F to 302°F
(Or None in the Case of No Switch), Environmental Options: XB14 (w/Heat Resistant Auto Switch)
Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Bore Size: 32mm, Stroke: 75mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: F7NJ--Solid State, Heat Resistant, 2-color Indication, 3 Wire NPN, LED, Lead Wire: L (3m), Number: S (1 pc.), Temperature Resistant: XB14 [w/Heat Resistant Auto Switch,
Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 63mm, Stroke: 75mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: F7NJ--Solid State, Heat Resistant, 2-color Indication, 3 Wire NPN, LED, Lead Wire: L (3m), Number: 3 pcs., Temperature Resistant: XB14 [w/Heat Resistant Auto Switch, (Max. 150Â