SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2B100-75DCMZ-L-A93V"

Thread size M6 x 1.0 l-9 M4 x 0.7 l-7 M5 x 0.8 l-8 M8 x 1.25 l-12 Bolt dimensions l-8 Dimension t N m 4.4 1.37 2.65 13.2 Tightening torque Square nut l t Service Life and Replacement Period of Shock Absorber Caution 1.

X417 on both sides (one on each side) X417 on L unit side X417 on H unit side L, H LH LH LH LH L, H, LS, HS L, H LH LH X416 X417 Note) For LS and HS, the stroke adjusting unit is mounted on one side only. 8-13-32 5 Holder Mounting Bracket q, w -X416/X417 Example Example Stroke adjusting unit with holder mounting bracket MY2H-A25L-X416 (L unit for MY2H25 and X416 bracket) L units with one

Applicable cylinder Port variation MY2C16/25/40 MY2H16/25/40 MY2HT16/25/40 R R L L L L L L L L R R R R R R L R Slide table operating direction 1118

Note 2) The tightening torque for the hexagon socket head cap screw (M2.5 x 6 L, M2.5 x 9.5 L) is 0.15 to 0.22 lbfft (0.2 to 0.3 Nm). Note 3) Tighten the hexagon socket head cap screws evenly.

Body Through-hole l l Maximum tightening torque (Nm) Max. screw-in l (mm) Bolt Model 2. If intermediate stops by external stopper is done, avoid ejection. If lurching occurs damage can result.

Knuckle Pin (common with double clevis pin) Rod End Nut d d Dd9 C m l L t m t H B Material: Carbon steel mm Material: Carbon steel mm Part no. Applicable bore size (mm) 20 25 32, 40 50, 63 80 100 Applicable bore size (mm) Snap ring l D d H B C Part no.

Knuckle pin (Common with double clevis pin) Rod end nut d d Dd9 C m L m l t t H B Metric Threads Metric Threads Bore size (mm) Bore size (mm) Snap ring d H B C t Dd9 l m Part No. Part No.

How to Order L 25 100 CG1Y Without auto switch L H7BW S 25 100 CDG1Y With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.

Grease pack GR-L-005 (5 g) GR-L-010 (10 g) GR-L-150 (150 g) CV MVGQ CC RB J D-X 20Data 10-4-13 14 Series CG1Y Dimensions: 20 to 100 Mounting bracket dimensions are the same as those of the low friction, double acting, single rod type of Series CG1Q. Please refer to page of Best Pneumatics Vol. 6.

Top Mounting Guide block l l l Model Bolt Maximum tightening torque (Nm) Maximum screw-in depth (l mm) Caution MXQR 6 MXQR 8 MXQR12 MXQR16 MXQR20 MXQR25 1.2 1.2 2.8 5.7 5.7 10.0 11.5 13.5 17.4 22.4 27.4 33.4 M3 x 0.5 M3 x 0.5 M4 x 0.7 M5 x 0.8 M5 x 0.8 M6 x 1 To prevent the workpiece holding bolts from touching the guide block, use bolts that are 0.5 mm or shorter than the maximum screw-in

m Dd9 L (Drill through) 3 x 18 l 4 x 25 l 4 x 35 l 4 x 36 l 0.040 0.076 CD-M03 CD-M05 CD-M08 CDP-7A 10 14 22 25 20, 25 32, 40 50, 63 80 3 4 4 4 4 4.5 5 5 36 51 72 78 44 60 82 88 0.050 0.093 0.065 0.117 0.065 0.117 l m L Note) When using cotter pins, flat washers are used together.

Lead wire length symbols: 0.5 m Nil 3 m L 5 m Z Solid state switches marked "" are produced upon receipt of order.

Lead wire length (m) Direct mounting Rail mounting Load voltage Indicator light Applicable load Pre-wire connector Special function Type Electrical entry Wiring (Output) 12, 16, 32 to 63 20 to 63 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC Perpendicular In-line Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit A96V A96 A76H Reed switch Solid state switch A93V M9NV M9PV M9BV

MX MTS MY Centralized piping on right CY MG CX R R L DL -X R L Slide table actuation direction 20Centralized piping on left Data R L L R R L Slide table actuation direction 4. Never disassemble the magnetic component parts (external slider, internal slider) of the actuator (cylinder). If will cause decline of the holding force, etc. 2.

s t o p p e r I n s t a l l p o s i t i o n o f e x t e r n a l s t o p p e r C auti on on usi ng exte rnal stoppe r R o t a r y a c t u a t o r w i t h A u t o s w i t c h A u t o s w i t c h s p e c i f i c a t i o n A u t o s w i t c h i n s t a l l a t i o n A u t o s w i t c h s e t p o s i t i o n I n t e r n a l s t r u c t u r e a n d o p e r a t i o n p r i n c i p l

Fixing bolt for guide L L Selection Caution 1. If intermediate stop by external stopper is done, avoid ejection. If ejection occurs, it may cause damage.

Lead wire*(m) Rail mounting 20 to 63 Load voltage Direct mounting 32 to 63 Indicator Special function Wiring (output) Electrical entry Applicable load (N) Style 0.5 () 3 (L) 5 (Z) DC AC Perpendicular In-line Perpendicular In-line 3 wire (NPN Equiv.) A76H A96V A96 IC 5V A72 A73 A72H A73H 200V Yes Yes No No Yes Yes Grommet Reed switch 12V 100V A93V A90V A93 A90 Option Part No.