SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2T80-500-D-A93"

Contact SMC regarding the specifications for psi unit and F. 229 Filter Regulator with Built-in Pressure Gauge with Backflow Function AWG20K/30K/40K Construction AWG20K AWG30K/40K B D P A A K U C C C S O P H L to K U C S O H L to B D D-D C-C A-A B-B !0 o !1 !0 o !1 y y !2 !

Note 3) ( ) in column W is the dimensions of D-A93.

Note 3) ( ) in column W is the dimensions of D-A93.

Hs A B A B Auto switch mounting height (mm) Proper auto switch mounting positions (mm) D-J79W D-F7BAL D-F7F D-F7NTL D-A7H D-A80H D-F7 D-J79 D-F7W D-F79W D-F7BA D-F7W D-F7F D-J79W D-F7WV D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-A73C D-A80C D-F7V D-F7WV D-J79C D-A79W D-A7 D-A80 Bore size (mm) D-A7/A80 D-A79W Bore size (mm) Hs Hs Hs Hs Hs Hs 20 B A B A B A A B 25 20 32 34 35 38 32.5 38.5

(V), D-A93(V), D-A96(V) (mm) Lead wire entries outside A A Model Mounting Switch operating range A B A B A B 54 MXY6 34 59 5 MXY8 MX 39 67 MXY12 MTS 47 MY Solid State Switch D-M9B(V), D-M9N(V), D-M9P(V) Lead wire entries inside (mm) B B CY Model Mounting Switch operating range A B A B A B 50 MXY6 2 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main

D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V 20 to 63 B A Hs 32 to 63 D-P3DWA B A Hs Auto Switch Proper Mounting Position Auto Switch Mounting Height (mm) (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9V D-P3DWA D-M9V D-M9WV D-M9AV D-A9 D-A9V D-P3DWA Bore size (mm) Bore size (mm) B 11 12.5 13 15 16 20 A 11 10.5 12 14 13.5 16.5 B 7 8.5 9 11 12 16 A 6 7.5

D-F9 D-F9 W B W 20 (22) A D-A9 V D-F9 V D-F9 WV W B Dimension inside ( ) is for model D-A9 V.

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Magnet: Built-in Magnet, Mounting: Center Trunnion, Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -

Magnet: Built-in Magnet, Mounting: Center Trunnion, Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: P5DW--Solid State, 2-color Indication, Magnetic Resist., 2 Wire, Lead Wire or Prewired Connector: 0.3m Cord Length, M12-4 Pin Connector, 3 & 4 Out, Number: -, Made to Order: -

Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC4 (w/Heavey Duty Scraper)

Magnet: D (Built-in Magnet), Mounting: T (Center Trunnion), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

47 C 11 21 27 34.5 35.5 44.5 A 19.5 29.5 35.5 43 44 53 6 10 15 20 25 32 Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

47 C 11 21 27 34.5 35.5 44.5 A 19.5 29.5 35.5 43 44 53 6 10 15 20 25 32 Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.