Bore size (mm) Stroke (mm) Bore size (mm) Manufacturable stroke range Applicable auto switch Note D25 50 100 75 125 150 175 200 250 300 400 500 12 25 to 150 D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-F7V D-F7/J79 D-J79C D-F7WV D-F7W/J79W D-F7BAL/F7BAVL D-F79F/F7NTL Switch mounting screw (M3 x 0.5 x 8l ) Square nut 12 20 -X BQ-1 20 25 to 300 32 2025 to 400 40 25 to 600 32 40 50 63 Switch
D-M9P, F9PV D-M9B, F9BV D-F9NW, F9NWV D-F9PW, F9PWV D-F9BW, F9BWV Dimensions ...13 to 16 Series CQSK How to Order . 1 12 16 5, 10, 15, 20, 25, 30 Construction . 17 20 25 5, 10, 15, 20, 25, 30 35, 40, 45, 50 Dimensions ...18 &19 Note 1) Standard equipment on long stroke model Non-rotating rod/Double acting double rod can be made.
range A B A B A B 54 MXY6 34 59 5 MXY8 MX 39 67 MXY12 MTS 47 MY Solid State Switch D-M9B(V), D-M9N(V), D-M9P(V) Lead wire entries inside (mm) B B CY Model Mounting Switch operating range A B A B A B 50 MXY6 2 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 38
30 40 13 XL-OMY0002 8 X L D 25 M9N A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW) D K (DN) () A / A F G A J B K C L M M9N D-M9N M9P D-M9P / 560 M9B D-M9B A90 D-A90 H0 H4 H5 5150 100 A93 D-A93 120 M9// 25H4 14 XL-OMY0002 9. 200 2580 100 100,160 [] 1 1.5 1 XLD-25,XLD-40,XLD-50,XLD-63,XLD-80 200 XLD-100,XLD-160 100 : FKM 110 Pa <> 15 XL-OMY0002
Refer to catalog E20-92F *-e.tgd Free S***r**'' O Dimensions and the most sensitive positions are same as the conventional types. & D-M9N (3-wire, NPN output) 0-F9F! g9*^'"t,*8:Wffi D-M9P ($wire, PNP outpu0 D-M9N D-M9P It"*,vp." D-M9B D-MgB (2-wire) [T:$8T.'}tr J' Range of load to wire:4 timgs New types t;(!ri.t{:nl,|1na!
, D-A93, D-A96, D-A90V, D-A93V, D-A96V (mm) B E Stroke Model Stroke A 100 30 50 75 20 10 100 75 50 30 20 10 8 (5.5) 11.1 (8.6) 13.8 (11.3) 18.7 (16.2) 8 (5.5) 3 (0.5) 11.1 (8.6) MXF8 9.5 10 5 10 27.1 (24.6) 23.8 (21.3) 20.7 (18.2) MXF12 12 29.1 13.1 13.1 44.8 (42.3) 44.2 (41.7) 68.7 (66.2) MXF16 17.2 46.8 25.8 15.8 MXF20 19.4 70.7 46.2 22.7 20.7 Solid State Switch: D-M9B, D-M9P, D-M9N
For details, refer to pages 443 and 445. 273
CHKD Series How to Mount and Move the Auto Switch
D-M9A Auto switch Auto switch B A (22) 22 B A Hs Hs 24.5 ( ): For D-A96 type 16 16 A B A B Hs Hs D-C7 D-C8 D-C73C D-C80C D-H7 D-H7W D-H7NF D-H7BA D-H7C B A Hs B Hs A Auto Switch Proper Mounting Position Auto Switch Mounting Height Auto switch model (mm) (mm) RSQ D-H7BA D-H7W D-H7 D-H7C D-H7NF D-H7 D-H7W D-H7NF D-H7BA D-C7/C8 Auto switch model D-C7 D-C80 D-C73C D-C80C D-M9V D-M9WV D-M9AV
Mounting correctly Mounting incorrectly
Auto switch Nil D None Built-in magnet Refer to page 308 for the part no. of auto switches.
Contact SMC regarding the specifications for psi unit and F. 229 Filter Regulator with Built-in Pressure Gauge with Backflow Function AWG20K/30K/40K Construction AWG20K AWG30K/40K B D P A A K U C C C S O P H L to K U C S O H L to B D D-D C-C A-A B-B !0 o !1 !0 o !1 y y !2 !
D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V 20 to 63 B A Hs 32 to 63 D-P3DWA B A Hs Auto Switch Proper Mounting Position Auto Switch Mounting Height (mm) (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9V D-P3DWA D-M9V D-M9WV D-M9AV D-A9 D-A9V D-P3DWA Bore size (mm) Bore size (mm) B 11 12.5 13 15 16 20 A 11 10.5 12 14 13.5 16.5 B 7 8.5 9 11 12 16 A 6 7.5
/Y7PV D-Y7W/Y7WV D-Y7BA D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BA 5 5 5 5.5 5.5 5 5 5 5.5 5.5 Perpendicular electrical entry type and D-Y7BAL cannot be mounted on 16, 20, 50 and 63.
Auto Switch Proper Mounting Position (mm) A B C D Auto switch model D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 36.5 41.5 56.5 67 67 83.5 92.5 D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 17.5 17.5 17.5 18 18 19.5 18.5 D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 24.5 29.5 44.5 55 55 71.5 80.5 D-A9 D-A9V K dimension (Switch rail height) Bore
Note 4) D-Z7 and D-Y types cannot be mounted. 25 to 63 (mm) Auto switch model D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Y7BA A B C D D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Y7BA D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Y7BA D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Y7BA D-A9 D-M9 D-M9W D-M9A D-A9 D-M9 D-M9W D-M9A D-M9 D-M9W D-M9A D-A9 D-M9 D-M9W D-M9A D-A9 Bore size (mm) 25 32 40 50 63 19 23 18 98 94 99 42 38 43 75 79 74 22.5 26.5
30 25 20 15 10 5 D-A9 x x x (2) 2 pcs. on same side Standard piping type(1) D-M9, D-F9W x x (2) D-A9V x x x D-A9 (2) x 1 pc. each on 2 sides D-M9, D-F9W (2) 2-port size D-A9V x D-A9 (2) x x x 2 pcs. on same side Axial piping type D-M9, D-F9W (2) x x D-A9V x x x D-M9V, D-F9WV x x D-F8 D-A9 x (2) 1 pc. each on 2 sides D-M9, D-F9W (2) D-M9V x 2-port size D-M9V, D-F9WV D-F8 Note 1) With the
Mounting bolt C D Mounting Bolt Size for NCDQ8B056 to 250(With Auto Switch) (Inch) Model C D Bolt size Model C D Bolt size NCDQ8B056-025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCDQ8B075-025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCDQ8B106-025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCDQ8B150-025 037 050 062 075 087 100 125 150 175 200 250
(V), D-M9N(V), D-M9P(V) 2-color Indication Solid State Switch: D-F9BW(V), D-F9NW(V), D-F9PW(V) Stroke (mm) Model 25 75 150 175 50 100 200 125 225 250 275 300 A 48.5 23.5 23.5 27.5 23.5 23.5 B 83.5 129.5 204.5 104.5 154.5 179.5 MXW8 W 36.5 11.5 11.5 15.5 11.5 11.5 V 95.5 141.5 216.5 116.5 166.5 191.5 A 27 27 47 27 27 B 128 203 108 153 178 MXW12 W 15 15 35 15 15 V 140 215
Confirm the Coordinates and Moments in Model Selection on page 1229 for details of floating Y and Z axes. 1196 MY1B Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) MY1B (Basic type) 25 to 40 Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model D-A9 D-A9V A A Bore size A 25 32 40 79 83 112.5 116.5 133.5