D Lever type models Caution RS (D) 32/40/50-L RS (D) 32/40/50-B RS (D) 32/40/50-C RS (D) 32/40/50-D RS (D) 32/40/50-E Mounting base 1. Do not allow a pallet to collide with the cylinder when the lever is upright.
B A C D A B C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6 46 26 46 26 30 42 42 30 10 48 28 48 28 32 44 44 32 Electrical entry (Fetching direction) Type Model Features D-A90 D-Z80 D-Y69A D-Y69B D-Y7PV D-Y7NWV D-Y7PWV D-Y7BWV 50, 63 Grommet (In-line) Without
Series MHL2 112210, 16, 20, 25, 32, 40 Parallel Type Wide Opening Air Gripper How to Order 11 Vacuum suction type Clean series 11MHL 2 16 D 1 M9N 22MHL 2 16 D 1 M9N Wide opening Number of auto switches 2 pcs. 1 pc. n pcs.
REC A dimension B dimension Auto switch model CX D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/F7WV D-F7BA D-F79F D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/FWV D-F7BA D-F79F CY D-F7NTL D-A73/A80 D-F7NTL D-A73/A80 MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800
REC A dimension B dimension Auto switch model CX D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/F7WV D-F7BA D-F79F D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/FWV D-F7BA D-F79F CY D-F7NTL D-A73/A80 D-F7NTL D-A73/A80 MQQ M Bore size (mm) RHC 10 35 35.5 45 44.5 40.5 39.5 MK(2) 15 34.5 35 62.5 62 40 57 20 64 64.5 50 49.5 69.5 44.5 RS Q G 25 44 44.5 71 70.5 49.5
Note D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F7BAVL D-F79F D-F7NTL Switch mounting screw RS H A 20, 25 BQ-1 (M3 x 0.5 x 8l) Square nut D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W RZQ Switch mounting screw 32, 40 50, 63 Magnetic body (Steel plate, etc.)
entry is not available for 50 and 63. ( ) D-Y69A, D-Y69B, D-Y7PV D-Y7NWV, D-Y7PWV, D-Y7BWV 8-12-23 24 Series MY1W Mounting of Auto Switch & Installation of Lead Wire Cover (50, 63) Caution Be sure to install a lead wire cover on the auto switches for size 50 and 63 cylinders.
D-F7, J79 D-F7V D-J79C D-F7W, J79W D-F7WV D-F7BAL D-F79F D-F7NTL Stroke range Only available for full strokes of 5 to 295 mm CEP1 Part no.: RZQA50-135-50 D-A7, A80 Example A 15 mm spacer is installed in a standard cylinder D-A73C, A80C CE1 RZQA50-150-50. The B dimension is 246.5 mm.
model D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-A5 D-A6 D-A3 D-A44 D-G39 D-K39 D-F5W D-J59W D-F5BAL D-F5 D-J5 D-F59F D-A59W D-F5NTL Bore size (mm) Bore size (mm) A B A B A B A B Hs Hs Ht Hs Hs Ht 125 125 2 75.5 69.5 74.5 70 116 126 4.5 4.5 9.5 9.5 0 0 2 140 140 2 81 76.5 80 76.5 124 134 4.5 4.5 9.5 9.5 0 0 2 160 160 2 89 87.5 88 87.5 134.5 144.5 4.5 4.5 9.5 9.5 0 0 2 180 180 7.5 97.0
Auto Switch Proper Mounting Position (Detection at Stroke End) (mm) Auto Switch Mounting Height (mm) D-M9l D-M9lW D-M9lA D-A9l Hs 20 26.5 25 29 32 32.5 40 37 50 42.5 63 49.5 D-M9l D-M9lW D-M9lA D-A9l Auto switch model Auto switch model Bore size A B A B 20 12 24 8 20 25 11.5 24.5 7.5 20.5 32 13 25 9 21 40 18 27 14 23 50 20 32 16 28 63 18.5 33.5 14.5 29.5 Bore size Note) Adjust the auto switch
D-Y7P D-A3D DF5 . modsl . gIM fc1iv .. ' 5[ ~F D-M9DWV D-Y7PV D-G39 D-A44 D--A6D D-J59W O-Y70W D-F5BAL .. , I 'Di M90 W DM9DAVL D-K39 D-A59W O-Y70WV D-F59F .
P Q S 5 to 50 40 33 Data 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43 5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75, 100 56.5 49.5 10 to 50 48.5 40.5 11 depth 8 50 58.5 50.5 15 20 64 10.5 M10 x 1.5 86 7 17 8 50 6.6 1/4 10.5 80 41 19 75, 100 58.5 50.5 10-4-7 8 Series CQ2Y Dimensions/63 to
D40 20.5 23.5 28.5 M14 x 1.5 50 26 28.5 33.5 M18 x 1.5 -X (mm) Without auto switch With auto switch A B A B 20U Z Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P Q S 5 to 50 40 33 Data 9 depth 7 32 50 43 13 16 45 7.5 M8 x 1.25 60 4.5 14 7 34 5.5 1/8 10.5 58.5 31.5 14 75, 100 50 43 5 to 50 46.5 39.5 9 depth 7 40 56.5 49.5 13 16 52 8 M8 x 1.25 69 5 14 7 40 5.5 1/8 11 66 35 14 75
M9 M9V F9W(V) B Electrical entry is in the direction C (mm) Proper mounting position Proper mounting position Proper mounting position D-M9 D-F9W D-M9V D-F9WV D-M9 D-F9W D-M9V D-F9WV D-M9 D-F9W D-M9V D-F9WV Model Model Model A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C
M9 M9V F9W(V) B Electrical entry is in the direction C (mm) Proper mounting position Proper mounting position Proper mounting position D-M9 D-F9W D-M9V D-F9WV D-M9 D-F9W D-M9V D-F9WV D-M9 D-F9W D-M9V D-F9WV Model Model Model A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,