side D D D D D D SS5V1-16S3AD-06B-C61 set (manifold part no.)
Outside diameter Nozzle size L2 Note1) D L1 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 1.5 2 1.5 2 1.5 2 1.5 2 2.5
Applicable model: D-A73, A73H, A73C, C73, C73C, E73A, Z73 D-R73, R73C, 97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed.
CNS D-H7C D-B5, D-B6, D-B59W CLS HS HS Auto switch Auto switch 12 8.5 CLQ 24.5 16 MLGP A B A B 33 38.2 RLQ MLU Proper Auto Switch Mounting Position Auto Switch Mounting Height ML1C Auto switch model D-C7/C80 D-H7 D-H7W D-H7NF D-H7BAL D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7/C80 D-C73C D-C80C D-B5/B64 DD-B5/B64 D-B59W D-G5NTL D-H7C D-C73C D-C80C D-G5NTL D-B59W -X Bore size (mm) A B A B A B A B
There may be large variations depending on the surrounding environment (variations on the order of 30%). 12 Solid State Switches/Direct Mount Type D-Y59 /D-Y69 /D-Y7P(V) A B A B Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.
There may be large variations depending on the surrounding environment (variations on the order of 30%). 12 Solid State Switches/Direct Mount Type D-Y59 /D-Y69 /D-Y7P(V) A B A B Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.
Reed auto switch: D-A9, D-A9V Solid state auto switch: D-M9(A), D-M9W D-M9 Compact auto switch D-A9 5 Air Slide Table MXQ Series Functional Options ' With buffer mechanism Protects workpieces and tools by eliminating impact at the extension stroke end Buffer unit is auto switch capable.
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 350mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 350mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 350mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Mounting Position (mm) Mounting Height (mm) CP95 Auto switch model D-G5NTL D-G59F D-H7C D-G5BAL D-C7,C8 D-H7 D-H7W D-H7F D-H7BAL D-B5,B6 D-B59W D-G5, K5 D-G5W D-K59W D-B5,B6 D-C7,C8 D-C73C D-C80C D-H7W D-H7F D-H7BAL D-G5 D-K5 D-G5NTL D-B59W D-H7 D-H7C C95 D-C73C D-C80C D-G5W, K59W D-G59F D-G5BAL C92 Bore B 18 (26) 18 (26) 19 (27) 21.5 (30.5) 26 (38) 26 (38) B 19.5 (27.5) 19.5 (27.5) 20.5
(When using 10-SS5Y-60-D, block disk is assembled on D side.) sheet. (When using 10-SS5Y-60-D, block disk is assembled on D side.)
D D side Applicable makers Valve stations MB1 For Mitsubishi Electric Corporation TA1 For OMRON Corporation FU1 For Fuji Electric Co., Ltd.
D D side Applicable makers Valve stations MB1 For Mitsubishi Electric Corporation TA1 For OMRON Corporation FU1 For Fuji Electric Co., Ltd.
CNS D-H7C D-B5, D-B6, D-B59W CLS HS HS Auto switch Auto switch 12 8.5 CLQ 24.5 16 MLGP A B A B 33 38.2 RLQ MLU Proper Auto Switch Mounting Position Auto Switch Mounting Height ML1C Auto switch model D-C7/C80 D-H7 D-H7W D-H7NF D-H7BAL D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7/C80 D-C73C D-C80C D-B5/B64 DD-B5/B64 D-B59W D-G5NTL D-H7C D-C73C D-C80C D-G5NTL D-B59W -X Bore size (mm) A B A B A B A B
Outside diameter Nozzle size L2 Note1) D L1 H1 VMG1-06-150-100 VMG1-06-200-100 VMG1-06-150-150 VMG1-06-200-150 VMG1-06-150-300 VMG1-06-200-300 VMG1-06-150-600 VMG1-06-200-600 VMG1-08-250-100 VMG1-08-300-100 VMG1-08-350-100 VMG1-08-250-150 VMG1-08-300-150 VMG1-08-350-150 VMG1-08-250-300 VMG1-08-300-300 VMG1-08-350-300 VMG1-08-250-600 VMG1-08-300-600 VMG1-08-350-600 1.5 2 1.5 2 1.5 2 1.5 2
(Only for units compatible with M12 PROFIBUS DP , CC-Link communication connectors) SY3000/5000 VQC1000/2000/4000 S0700 SV1000/2000/3000 D D D D Note) The SY3000/5000, VQC1000/2000/4000, and S0700 are not yet UL-compatible.
Auto Switch Proper Mounting Position (Detection at stroke end) and Its Mounting Height Auto Switch Proper Mounting Position [mm] Auto switch model D-A5l D-A6l D-A3l D-A3lC D-A44 D-A44C D-G39 D-G39C D-K39 D-K39C D-B59W D-Z7l D-Z80 D-Y59l D-Y69l D-Y7P D-Y7PV D-Y7lW D-Y7lWV D-Y7BA D-G5l D-K59 D-G5NT D-G5lW D-K59W D-G5BA D-G59F D-F5l D-J59 D-F59F D-F5lW D-J59W D-F5BA D-M9l D-M9lV D-M9lW D-M9lWV