The number of the switches: N/A, Type of Auto Switch Mounting: Rail mounting, Head Cover Port Position: Axial direction, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Basic type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet
The number of the switches: N/A, Type of Auto Switch Mounting: Rail mounting, Head Cover Port Position: 90° to axis, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Basic type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting opt, Cylinder, Air, ROUND BODY CYLINDER, 359, 0.025 lb
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
Magnet: Built-in Magnet, Series: J2K, Mounting: Basic, Bore Size: 10mm, Stroke: 45mm, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Rail Mounting
Magnet: Built-in Magnet, Series: J2K, Mounting: Basic, Bore Size: 10mm, Stroke: 30mm, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting
Magnet: Built-in Magnet, Series: J2K, Mounting: Basic, Bore Size: 10mm, Stroke: 30mm, Action: Single Acting, Spring Extend, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches
This is a legacy product. Please contact us for the latest version.sales@ocaire.com