Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9P, Lead
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Clean Series: Relief Type, Magnet: Built-in Magnet, Series: J2, Mounting: Double-side Bossed, Bore Size: 10mm, Stroke: 30mm, Cushion: Rubber Bumper, Standard, Head Cover Port Location: Perpendicular to Axis, Version: Z, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting
Series CJ2 miniature cylinders available in spring return, spring extend, or double acting offer stainless steel tubing and stainless steel rods. The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis. Series CJ2 is auto switch capable Spring extend or spring return, Bore sizes:
Magnet: D (Built-in Magnet), Series: J2X, Mounting: B (Basic), Bore Size: 10mm, Stroke: 60mm, Head Cover Port Location: Perpendicular to Axis, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Magnet: D (Built-in Magnet), Series: J2X, Mounting: B (Basic), Bore Size: 16mm, Stroke: 60mm, Head Cover Port Location: Perpendicular to Axis, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Magnet: Built-in, Mounting: Head Flange, Bore: 6mm, Stroke: 60mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: Rubber Bumper, Series: J2
Magnet: Built-in Magnet, Series: J2K, Mounting: Double Clevis, Bore Size: 10mm, Stroke: 60mm, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting
Magnet: Built-in Magnet, Series: J2K, Mounting: Single Foot, Bore Size: 10mm, Stroke: 60mm, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting
Magnet: Built-in Magnet, Series: J2W, Mounting: Front Flange, Bore Size: 16mm, Stroke: 60mm, Cushion: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting
Magnet: Built-in Magnet, Series: J2Z, Mounting: Single Foot, Bore Size: 10mm, Stroke: 60mm, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: Band Mounting
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Speed, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Low Speed, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.12~0.7, Cushion: Rubber cushion, Auto Switches: None, Lead