SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2D10-125Z-M9NWL-A"

model Auto switch model D-G59F D-G5 D-K59 D-G5W D-K59W D-G5NTL D-G5BAL D-C7 D-C80 D-H7 D-H7W D-H7NF D-H7BAL D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-H7C D-H7 D-H7C D-H7NF D-H7W D-H7BAL D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-C7 D-C80 D-C73C D-C80C D-A9 D-M9 D-M9W D-M9 D-M9W D-B5 D-B64 D-B59W D-C73C D-C80C D-A9 Bore size (mm) Bore size (mm) Hs Hs Hs Hs Hs A B A B A B A B A B 16 (24) A B A A

R1 ND MM ND MM R1 MM E1 ND NX1 A U1 R2 H Z E1 NX U1 L1 A A NX A1 (Min.) A1 U1 L1 Applicable bore size 20 25, 32 40 MM L1 NX NDH10 R1 E1 A1 U1 A A H MM NDH10 NX1 U1 R2 Y Z Part no.

MA a CHM A MA a Cushion adjustment screw Air release R (max.)

F E D A 60.6 95.9 121.5 B 64.6 97.5 121.5 C 70.6 107.9 134.5 H 3.4 4.5 6.6 E 15 25 45 F 26 38 64 G 4.9 6.4 11.7 D 77.2 115.5 145.5 Model MYC-S16A MYC-S25A MYC-S40A Applicable cylinder MY2C16 MY2C25 MY2C40 A set of side supports consists of a left support and a right support.

A Normally OFF detection (1) (2) B Normally ON detection Adjust the switch position according to load and speed. (mm) A 2 2.5 4 5 5.5 10 B Model MXS6 MXS8 MXS12 MXS16 MXS20 MXS25 3 86

D-A59W D-Z7/Z80 D-M9/M9W D-M9A Bore size (mm) Bore size (mm) D-Z7/Z80 D-A5/A6 A B A B A B A B A B A B Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs 40 50 63 80 100 40 50 63 80 100 11.5 8.5 8 5 13 10 5 2 27 28.5 27 34 35.5 28.5 29 27 13 8 9.5 4.5 14.5 9.5 6.5 1.5 33 33.5 33 38.5 39.5 34.5 33 33 4.5 0 8.5 3.5 47.5 38.5 14.5 9.5 11 6 16 11 8 3 38.5 38 38.5 43.5 45 38.5 28 37 8.5 3.5 12.5 7.5 54

B A B A B A B How to Mount and Move the Auto Switch How to Mount and Move the Auto Switch Flat head watchmakers screwdriver Auto switch mounting screw (M2.5 x 4 l) Accessory Auto switch mounting nut M2.5 x 4 l 5 to 6 Note) When tightening an auto switch mounting screw, use a watchmakers screwdriver with a grip diameter of 5 to 6 mm.

Fittings & Tubing Air Cylinders Rotary Actuators BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) Switch bracket (Resin) Transparent (Nylon) Note 1) Auto switch a e White (PBT) b Switch holder d Auto switch mounting screw c Auto switch mounting band Band

28.5 30 32.5 B 9.5 20.5 23.5 25 29 30.5 33 B 6.5 17.5 20.5 22 26 27.5 30 A 23.5 27.5 26.5 34 34 41.5 45 A 28.5 32.5 31.5 39 39 46.5 50 A 20.5 26 25 32.5 32.5 40 43.5 A 23 27 26 33.5 33.5 41 44.5 A 23.5 27.5 26.5 34 34 41.5 45 A 20.5 24.5 23.5 31 31 38.5 42 A 24.5 30 29 36.5 36.5 44 47.5 20 32 40 50 63 80 100 Note) Adjust the auto switch after confirming the operating conditions in the actual

Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

Magnet: Built-in, Mounting: Double Clevis, Bore: 10mm, Stroke: 125mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: -,

Z (Example) M9NWZ DRelay, PLC 12 V 24V Yes Grommet Diagnostic indication (2-color indication) IC circuit -X Refer to pages 1784 and 1785 for details of auto switches with a prewired connector.

Magnet: Built-in, Mounting: Double Clevis, Bore: 10mm, Stroke: 30mm, Head Cover: Perpendicular to Axis, Pivot Bracket: Pivot Bracket not Assembled, Rod End Bracket: None, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: Rubber Bumper

, z + A = 100 y, z + A a 100 10 y, z + A = 200 y, z + A = 200 y, z + A = 300 y, z + A = 300 1 1 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 700 800 Stroke [mm] Stroke [mm] [Graph 6] Allowable load mass by stroke 32 [Graph 5] Allowable load mass by stroke 25 100 100 y, z + A = 0 y, z + A = 0 y, z + A = 50 y, z + A = 50 10 Load mass [kg] Load mass [kg] 10 y, z + A = 100 y, z + A =

Consider the possibility of a reduction in the circuit air pressure caused by a power failure. When a rotary actuator is used as clamping mechanism, there is a danger of workpiece dropping if there is a decrease in clamping force, due to a drop in circuit pressure caused by a power failure.

With end lock Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Piston seal A A A CX2 R H R H CXW 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.

Bore size (mm) Auto switch mounting surface 20, 25 63, 80, 100 32, 40, 50 Port side Port side Port side C A C A C A B B B Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface Auto switch model A, B, C sides Port side Port, A, B, C sides Port, A, B, C sides 1. BQ-2 2. BQ2-012 Two kinds of auto switch mounting brackets are used as a set.

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.