Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 1200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 370, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 32mm, Stroke: 50mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Locking, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 32mm, Stroke: 150mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Locking, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 32mm, Stroke: 450mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Locking, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Data A Volume of cylinder/Capacity of converter 180 160 140 125 100 300 250 800 700 600 How to Select 200 10,000 8,000 6,000 5,000 4,000 3,000 500 400 qSelect the bore size of air-hydro cylinder 80 First of all, select a bore size from data
l b --" ,m'i$;:f, 4ra 20 Standard Stroke lmm) 30 40 50 60 75 100 125 175 200 225 250 275 300 350 400 150 Y f r N t * w -l Yw Y Ns a a a a a a a a a a a a a o a a a a a a a a a a a a a a a a a '*?
Operating Pressure 250 psi 17.5 kgf/cm) Min.
to 150 151 to 200 201 to 250 S ZZ S ZZ S ZZ S ZZ S ZZ 20 8 20 M4 x 0.7 87 120 112 145 137 170 25 8 20 M5 x 0.8 87 120 112 145 137 170 32 12 20 M6 x 1 89 122 114 147 139 172 164 197 40 13 21 M8 x 1.25 113 150 138 175 163 200 188 225 213 250 Symbol * When female thread is used, use a thin wrench when tightening the piston rod. * When female thread is used, use a washer etc. to prevent the
Nil S n Standard stroke Standard stroke (mm) 100, 150, 200, 250, 300 350, 400, 450, 500, 600, 700 Bore size (mm) Type of auto switch 15, 32 Nil Select auto switches from the table below.
UU (TT) N A Rc 3/8 (Port) Rc 3/8 (Port) Z + Stroke T-slot section for mounting UU (TT) PL Rc 3/8 (Hexagon socket head taper plug) Rc 3/8 (Port) Rc 3/8 (Port) Rc 3/8 (Hexagon socket head taper plug) MY1HTG MY1HTG (mm) A EY H HL L LL N NH NW PA PB PE PG Model MY1HT50 MY1HT63 220 207 97.5 145 23 210 102 30 143 254 90 200 15 50 237 104.5 170 26 240 117 35 168 274 100 17.5 (mm) PL QE S Z RR
mm 250 to 800 mm +1.4 0 CHS Stroke length tolerance CH2 Basic type, Axial foot type Head flange type, Rod flange type Single clevis type Mounting type CHA Note) Refer to page 214 for definitions of terms related to pressure.
Lead wire length (m) Load voltage Auto switch model Indicator light Special function Type Electrical entry Pre-wire connector Wiring (Output) Applicable load Rail mounting Band mounting 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit C76 A76H Reed switch Solid state switch Grommet 200 V 100 V 12 V 12 V C73 C73C H7A1 H7A2 H7B H7C H7NW
Lead wire length (m) Load voltage Auto switch model Indicator light Special function Type Electrical entry Pre-wire connector Wiring (Output) Applicable load Rail mounting Band mounting 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit C76 A76H Reed switch Solid state switch Grommet 200 V 100 V 12 V 12 V C73 C73C H7A1 H7A2 H7B H7C H7NW
Bore size Stroke NCA Standard stroke (mm) Bore size (mm) 32 40 Max. stroke (mm) 200 250 32 40 10, 25, 40, 50, 80, 100, 125, 160, 200, 250 Flange, Foot (1 pc.) C76F32A C76F40A DFlange, Foot (2 pcs. with mounting nut 1 pc.)
Bore size Stroke NCA Standard stroke (mm) Bore size (mm) 32 40 Max. stroke (mm) 200 250 32 40 10, 25, 40, 50, 80, 100, 125, 160, 200, 250 C76F40A C76F32A Flange, Foot (1 pc.) DFlange, Foot (2 pcs. with mounting nut 1 pc.)
Please contact SMC in this case. 356 Series MGG Guide Cylinder Specifications JIS Symbol Standard Stroke Model (Bearing type) Standard stroke (mm) Long stroke (mm) Bore size (mm) 20 75, 100, 125, 150, 200 250, 300, 350, 400 25 350, 400, 450, 500 32 350, 400, 450, 500, 600 40 350, 400, 450, 500, 600, 700, 800 MGGM(Slide bearing) MGGL(Ball bushing bearing) 75, 100, 125, 150, 200, 250, 300 50
250 Internal grip 300 200 Pressure 0.6 MPa Gripping force (N) Gripping force (N) Pressure 0.6 MPa 250 0.5 MPa 0.5 MPa 150 200 0.4 MPa 0.4 MPa 0.3 MPa 0.3 MPa 150 100 0.2 MPa 0.2 MPa 100 50 50 0.1 MPa 0.1 MPa 0 0 10 10 20 20 30 30 40 40 50 50 60 60 70 70 Gripping point L (mm) Gripping point L (mm) MHSJ3-63D MHSJ3-63D 400 500 Pressure 0.6 MPa Pressure 0.6 MPa 400 Gripping force (N) Gripping