, 200 1/8 Relief type Vacuum suction type 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 25, 50, 75, 100, 125, 150, 200 Available Available (40 to 63) 11-/22-CG120 11-/22-CG125 11-/22-CG132 11-/22-CG140 11-/22-CG150 11-/22-CG163 11-/22-CG180 11-/22-CG1100 Non-lube Double acting, Available 20 25 32 40 50 63 80 100 single rod 1/8 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Note
C73 21 C D M 2 R A 40 150 C73 Number of auto switches Mounting style 2 pcs. 1 pc.
Extension end 8 10, 20, 30, 40, 50, 75 Rubber stopper Retraction end Both ends 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Standard type Nil PNote 1) Axial piping type Note 1) The combination of axial piping type and both ends adjusters or retraction end adjusteris not
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 20mm, Stroke: 150mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type), Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 20mm, Stroke: 150mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type), Auto Switch: H7BW--Solid State, 2-color Indication, 2 Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 20mm, Stroke: 150mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: H7BW--Solid State, 2-color Indication, 2 Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
, 50, 75, 100, 125, 150, 200 MB 40, 50, 63 25, 50, 75, 100, 125, 150, 200, 250, 300 Please consult with SMC for strokes which exceed the standard stroke length.
Grease pack part no.: GR-L-005 (5 g) GR-L-010 (10 g) GR-L-150 (150 g) RZQ Warning 1. It might not be able to control CUX10 by meter-out at a low speed operation. DCaution 1. For CUX10, up to 0.1 Nl/min (ANR) of internal leakage is anticipated due to cylinder structure.
Low Friction: Double Acting Single Rod Series CJ2Q 10, 16 How to Order Bore size 10 16 10mm 16mm Mounting Basic Axial foot Front flange Double clevis Standard stroke (mm) B L F D 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 CJ2Q L 16 60 Standard L 16 60 C73 CDJ2Q With auto switch Number of switches With auto switch (Built-in magnet) 2 1 n S n Auto switch
45, 60, 75, 100, 125, 150, 175, 200 Standard Non-lube Double acting Single rod 15, 30, 45, 60 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Air cushion is not available for 21-/22-.
BBA3: For D-B5/B6/G5 BBA4: For D-C7/C8/H7 D-H7BAL switch is set on the cylinder with the stainless steel screws above when shipped.
BBA4: D-C7/C8/H7 "D-H7BAL" switch is set on the cylinder with the screws above when shipped.
Y59B 21 C D A 2 B 40 150 Y59B Nil Built-in magnet Number of auto switches No 2 pcs. 1 pc.
HR MO RF WL WL KA 0.1 C 8-J NA (mm) Stroke range Bore size (mm) A AL B1 C D DL2 E F GA GB H H1 HR HN (max.)
BBA3: For D-B5/B6/G5/K5 BBA4: For D-C7/C8/H7 D-G5BAL/H7BAL switch is set on the cylinder with the stainless steel screws above when shipped.
Models Standard strokes (mm) 32 40 50 63 MGP 25, 50, 75, 100, 125, 150, 175 200, 250, 300, 350, 400 M L Intermediate strokes (in 5mm increments) are produced by installing spacers of 5, 10, 15 and 20mm widths. When a special intermediate stroke body is needed, contact SMC.
lo switches Bore sizel E--6,"'"-l IE ro.m I IE re '. 1 Port location on head cover stroke (l00ihs o Standard 50, 100, 150,200 50, 100, 150, 200, 300.400, 500,600 50, 100, 150. 200,300,400, 500,600,700,400 Doub e actino Sinole aclino sorinq relurn Sinale aclinq sprinq extend Se Caralog N301 ior slandard stroke Lenglhs on lypes otherrhan single rod 'lnrermedate shkes can b nanufacrured upon
s o.50 o.8e4 o93 0.75 0.18 %-18 0.50 0.95 2.94 106 (1 0.312 %-24 0.50 o.624 0.25 1.12 o.12 0.88 0.88 0.24 %-8 0.62 1.17 3.25 0.la7 Wzo 0.75 0.7i19 o 1.t2 0.25 1.06 'L06 o.25 %-16 ora 1.62 400 150 t1%l o.87 1h-20 o_75 o.749 0.38 1.56 0.25 1.25 1.25 o.25 3l-16 0.88 '1.50 3.69 Double End : NC.