CQ2 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 Built-in Magnet Cylinder Model Double acting Action D 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 RQ If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the auto switch. (Example) CDQSL25-30D 25 For Manufacture of Intermediate Strokes, refer to page 552.

TYPE1 TYPE1 TYPE1 TYPE1 TYPE1 TYPE1 TYPE1 TYPE1 MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN (mm) 1 2 3 4 5 6 7 8 Stations Rail length L1 110.5 123 148 173 185.5 210.5 223 248 Mounting pitch L2 100 112.5 137.5 162.5 175 200 212.5 237.5 Manifold length L3 L4 82 102 122 142 162 182 202 222 12 12 12.5 12.5 13 13

Standard Strokes Bore size [mm] Standard stroke [mm] Note 1) Long stroke [mm] Note 2) 40 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500 800 Refer to pages 18 to 23 for cylinders with auto switches. 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500, 600 1200 Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at

, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80: 1400 100: 1500 Refer to pages 19 to 23 for cylinders with auto switches. 80, 100 Intermediate strokes not listed above are produced upon receipt of order.

Bore size (mm) Standard stroke (mm) Note 1) Long stroke (mm) Note 2) Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at stroke end) and mounting height Operating range Auto switch mounting bracket/Part no. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600

Mass (g) Standard stroke (mm) End lock additional mass Model D25 52 138 186 350 487 918 1,420 5 36 10 40 15 44 20 48 30 56 50 157 222 400 547 1,000 1,533 75 175 258 450 608 1,083 1,645 100 194 294 500 669 1,165 1,758 125 549 729 1,247 1,870 150 599 790 1,330 1,983 175 649 851 1,412 2,095 200 699 912 1,495 2,208 MTS8 MTS12 MTS16 MTS20 MTS25 MTS32 MTS40 29 34 42 55 90 133 -X Bore size (

Cylinder stroke Bore size (mm) 50-5 0.21 0.35 0.63 0.80 25-5 0.18 0.31 0.58 0.73 75-5 0.23 0.39 0.68 0.86 100-5 0.26 0.43 0.73 0.93 125-5 0.29 0.46 0.78 0.99 150-5 0.32 0.50 0.83 1.06 175-5 0.34 0.54 0.88 1.12 200-5 0.37 0.58 0.93 1.19 250-5 0.43 0.66 1.03 1.33 300-5 0.48 0.74 1.13 1.45 32 40 50 63 Find the first-stage stroke by adding the mass of an additional 10 mm as in the table below

Standard Strokes Bore size [mm] Standard stroke [mm] 12, 16 10, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250 20, 25 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 32 to 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 Made to Order: Individual Specications (For details, refer to page 491.)

Data Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL Auto Switch Mounting Bracket Part No.

Weight [g] Precautions Caution D-M9N(V) D-M9P(V) D-M9B(V) Auto switch model 0.5 8 8 7 Fix the auto switch with the existing screw installed on the auto switch body.

For 10, 16, 20 Lead wire length (m) Auto switch model Pre-wire connector Applicable load Perpendicular In-line Load voltage Indicator light Electrical entry Special function Wiring (Output) Type 0.5 (Nil) 3 (L) 5 (Z) DC AC A96 A93 M9N M9P M9B F9NW F9PW F9BW A96V A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN equivalent) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP)

Therefore, it is important to secure as a danger zone a cylindrical area with the length of the clamp arm as its radius, and the stroke plus 20 mm as its height. 123 135 155 203 363 518 65 56 Head flange (including mounting bolt) 130 150 175 209 371 578 69 58 Calculation: (Example) MKG20-10RNZ Standard calculation: MKB20-10RZ Extra weight calculation: Head flange With arm ...222 g .130

Calculation: (Example) CDM3B40-175 Basic mass of movable parts: Table (2) Rod end [Basic], Bore size [40] 147.3 g Additional mass: Additional mass of stroke 60.6 x 175/50 = 212.1 g 212.1 g Switch magnet 6.0 g OUT 94.2 125.6 314 62.8 157 188.4 219.8 20 8 IN 79.2 105.6 264 52.8 132 158.4 184.8 OUT 147.3 196.4 491 98.2 245.5 294.6 343.7 25 10 IN 123.6 164.8 412 82.4 206 247.2 288.4 OUT

MGQ 12, 16 M L 10, 20, 30, 40, 50, 75, 100 20, 30, 40, 50, 75, 100 125, 150, 175, 200 M L MGQ 20, 25 MGJ MGQ 32, 40 50, 63 80, 100 25, 50, 75, 100, 125 150, 175, 200 M L MGP MGQ OUT(N) IN(N) Theoretical Output (N) Bore size (mm) MGG Operating pressure (MPa) Rod size (mm) Piston area (mm2) Operating direction 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 MGC Made to Order Specifications (For details

-X1247 75, 100, 125, 150, 175 200, 250, 300 350, 400, 450, 500 600, 700, 800 20, 25 32, 40, 50 63, 80 75, 100, 125, 150, 175 200, 250, 300 350, 400, 450, 500, 600 700, 800, 900,1000 Intermediate strokes and strokes shorter than 75 mm are also available.

, 200 50, 75, 100, 125, 150, 175, 200 CKGA series End bracket Nil Y None Double knuckle joint (with tap) CKPA series Note) A knuckle pin, cotter pins and flat washers are provided as a standard for Y.

Full stroke Note 1) 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 Bore size (mm) Note First-stage stroke Note 2) 5 mm to "Full stroke" 5 mm RS Q G Note 1) RZQB (through hole type) is only available for full strokes 25, 50 and 75. Note 2) Available in 1 mm increments.

Prewired connector Load voltage Lead wire length (m) Indicator light Port on the right, cushion valve on top Special function Type Electrical entry Wiring (output) Applicable load Auto switch model 0.5 (Nil) 3 (L) 5 (Z) 1 (M) AC DC D M9N M9P M9B M9NW M9PW M9BW M9NA 3-wire (NPN) IC circuit 5 V, 12 V 3-wire (PNP) 2-wire 24 V Reed auto switch Solid state auto switch Port on the right, cushion

Auto switches of D-M9N, D-M9P and D-M9B are used. Auto switches of D-M9NV, D-M9PV and D-M9BV are used. Max. Protrusion of Auto Switch from Edge of Body: L, H Max.