Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: NPT, Port Size: 3/8, Normally Open, Closed: N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: NPT, Port Size: 1/2, Normally Open, Closed: N.C., Normally Closed, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: NPT, Port Size: 1/2, Normally Open, Closed: N.C., Normally Closed, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: Rc, Port Size: 3/8, Normally Open, Closed: N.C., Normally Closed, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: Rc, Port Size: 3/8, Normally Open, Closed: N.C., Normally Closed, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: Rc, Port Size: 3/8, Normally Open, Closed: N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: Rc, Port Size: 3/8, Normally Open, Closed: N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: Rc, Port Size: 1/2, Normally Open, Closed: N.C., Normally Closed, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: Rc, Port Size: 1/2, Normally Open, Closed: N.C., Normally Closed, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: Rc, Port Size: 1/2, Normally Open, Closed: N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: Rc, Port Size: 1/2, Normally Open, Closed: N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: without Attachments, Port Size: 1/2, Normally Open, Closed: N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: without Attachments, Port Size: without Attachments, Normally Open, Closed: N.C., Normally Closed, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: without Attachments, Port Size: without Attachments, Normally Open, Closed: N.C., Normally Closed, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: without Attachments, Port Size: without Attachments, Normally Open, Closed: N.C., Normally Closed, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: without Attachments, Port Size: without Attachments, Normally Open, Closed: N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: without Attachments, Port Size: without Attachments, Normally Open, Closed: N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
BM53 NAM450 BM54 NAM550 BM55 NAM650 BM56 NAM850 BM57 Filter element NAM150 AM-EL150 NAM250 AM-EL250 NAM350 AM-EL350 NAM450 AM-EL450 NAM550 AM-EL550 NAM650 AM-EL650 NAM850 AM-EL850 GD40-2-01Differential pressure gauge *0.7MPa Supply, 0.03MPa or less pressure drop (Clearance required for cartridge change) Model Port NPT A mm B mm C mm NAM150-N02D 14 159 63 10 NAM250-N03D 38 172 76 10 NAM350-N04D
This is a legacy product, and replaced byAFM40-N04D-Z-A, MIST SEPARATOR, MODULAR, AIRLINE EQUIPMENT, AFM MASS PRO, EC, AFM 3/8INCH MODULAR (NPT), 1.32277 lb
This is a legacy product, and replaced byAFM40-N04D-2Z-A, MIST SEPARATOR, MODULAR, AIRLINE EQUIPMENT, AFM MASS PRO, FC, AFM 1/2INCH MODULAR (NPT), 1.32277 lb