N01 Connection NPT 1/8 N02 Connection NPT 1/4 Port size N03 Connection NPT 3/8 Option specifications Application Size Symbol N04 Connection NPT 1/2 IRV3000 IRV2000 IRV1000 F01 Connection G 1/8 01 02 03 04 1/8 1/4 3/8 1/2 F02 Connection G 1/4 F03 Connection G 3/8 F04 Connection G 1/2 Accessory (Option) Part No. Part no.
12 90 (5.0) A B D NAN500-N06 34 160 (8.8 NAN200-N02 63 22 19 NAN600-N10 1 270 (15) NAN300-N03 84 25 22 NAN700-N12 114 440 (24) NAN400-N04 92 30 27 NAN800-N14 112 590 (33) NAN500-N06 107 46 36 NAN900-N20 2 960 (53) NAN600-N10 132 50 41 Note: When ordering PT Ports, remove (N) from Model Number Eg: AN200-02 NAN700-N12 200 74 55 NAN800-N14 233 74 60 NAN900-N20 263 86 70 FOR FURTHER TECHNICAL
Nozzle Diameter: 20 (ø2.0mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: N03 (Screw-in NPT 3/8), VAC: N04 (Screw-in NPT 1/2), EXH: N04 (Screw-in NPT 1/2), Accessories: N (w/o Bracket, w/o Silencer)
Nozzle Diameter: 20 (ø2.0mm), Vacuum Pressure: S (-90 kPa), SUP: N03 (Screw-in NPT 3/8), VAC: N04 (Screw-in NPT 1/2), EXH: N04 (Screw-in NPT 1/2), Accessories: N (w/o Bracket, w/o Silencer)
Nozzle Diameter: 20 (ø2.0mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: N03 (Screw-in NPT 3/8), VAC: N04 (Screw-in NPT 1/2), EXH: N04 (Screw-in NPT 1/2)
Nozzle Diameter: 20 (ø2.0mm), Vacuum Pressure: S (-90 kPa), SUP: N03 (Screw-in NPT 3/8), VAC: N04 (Screw-in NPT 1/2), EXH: N04 (Screw-in NPT 1/2)
N06 NPT3/4 5/16(inch) 6) Rated voltage N04 2xNPT1/2 5 DC24V *1: The thread shape complies with the G thread standard (JIS B 0202).
N06 NPT3/4 5/16(inch) N04 2xNPT1/2 6) 5 DC24V *1G JIS B0202 ISO1603 ISO1179 8) Z 7 L L 0.3(m) 11) A NPN LO B PNP M M 0.3(m) MO 12) 9) M SI (kPa) D P (:psi) E 10) 14 GN (G) B G *7ZL212 27mm ZL212 (2 /1 , 4 ) E (2 ) F (2 ) V (1 ) 13 G 2m) W (2m) 5 No.ZL3-OM00801-A 2. 2.1 (1/P) (2/V) ZL3 ZL6 (3/E) // / (G) (2/V) 2.2 ZL6 1 ZL6 (ZL6-SC1-A) 2), 6 No.ZL3-OM00801-A 3. 3.1
Nil Silencer exhaust 6 600 L/min (ANR)*1 Symbol Vacuum (2/V) port Supply (1/P) port 06 Rc3/4 P Port exhaust (Rc1, G1, NPT1)*3 *1 Branch, Port exhaust 8 (Metric) 04 2 x Rc1/2 (Branch specification) F06 G3/4*2 *3 The same thread type selected for e is used for the port. t Supply valve/Release valve combination u Electrical entry F04 2 x G1/2*2 (Branch specification) N06 NPT3/4 5/16" (Inch) N04
Measure 2R when the tube breaks or is crushed. 20 m roll Fixed end Tubing size (Metric size) Model TU0425 TU0604 TU0805 TU1065 TU1208 O.D. (mm) 4 6 8 10 12 I.D.
Measure 2R at the point where the outside diameters rate of change is 5%. Max.
-1 (Plug-in type) ARBF2000-00-P-2 (Non plug-in type) 01 02 01 02 VFS VS4 VQ7 EVS Individual EXH spacer VFN Interface regulator Rc 1/8, 1/4 EXH port SUP block disk: AXT625-12A EXH block disk: AXT625-12A Release valve spacer VVFS2000-24A-1 (Plug-in type) VVFS2000-24A-2 (Non plug-in type) R L R L Blocking plate Valve VFR210 (Single) Release valve spacer Rc 1/4 SUP port Note) VVFS2000-24A-1/2R
(mm) 2R 6.5 5 4 2.5 8 I.D. (mm) H Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed.
(mm) 2R 6.5 5 4 2.5 8 I.D. (mm) H Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed.
(Refer to the web catalog on the SMC website or Best Pneumatics No. 6 for details Head side: AS*2Q Series Rod side: AS*2R Series 2) To perform operation on the cylinder retracted side: Head side: AS*2R Series Rod side: AS*2Q Series 6.
Please note that the refraction value is not warranted because of the value when 2R is measured by the method in the right figure if the tube is bent or flattened, etc. 2R Fixed end At a temperature of 20oC, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameters rate of change is 5%. Max.
Specifications Applicable model Base mounted type (SYJ714R,SYJ724R) 30inHg~100(--100kPa~0.7) 22~100(0.15~0.7) External pilot pressure Main pressure Operating pressure range PSI(MPa) Note) Externally piloted body ported valves(SYJ7 2R) can only be used on the manifold.
Example) AF30-03BD-2R-A-X2141 r With element service indicator A special body type is required to mount the element service indicator. It cannot be mounted on a standard body.
Ex.) 2R Without valve function Pressure differential AFD2000 auto drain 4 1 D 3 8 1 2 3 4 Float auto drain (N.O.)
Example) AF30-03BD-2R Made to Order (Refer to page 334 through to 336 for details.)