Metric size Inch size Model Port size Pilot port 6 8 10 12 1/4" 5/16" 3/8" 1/2" ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 ASP330F-N01 ASP430F-N02 ASP530F-N03 ASP630F-N04 R 1/8 M5 x 0.8 R 1/4 Rc 1/8 R 3/8 Rc 1/8 R 1/2 Rc 1/4 R 1/4 G 1/8 R 3/8 G 1/8 R 1/2 G 1/4 NPT 1/8 10-32 UNF NPT 1/4 NPT 1/8 NPT 3/8 NPT 1/8 AS NPT 1/2 NPT 1/4 Note
Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure In the OUT2 setting, the above P_1, n_1 and H_1 will be P_2, n_2 and H_2 respectively.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
KNH-R02-100 KNH-R02-150 KNH-R02-200 1 1.5 2 R1/4 14 52 46 D H1 A L1 Reference dimensions after R thread installation Low noise nozzle with male thread: KNS (mm) thread L1 A Width across flats H1 D Connection Nozzle size Part no.
DIN rail is not suitable for port size F02 (G1/4). No lead wire 1
The Pressure switch is a UL approved product only if it has a mark on the body. A pressure sensor of stainless steel diaphragm is used for this product.
Bracket A (Part No.: ZS-50-A) Bracket B (Part No.: ZS-50-B) -13No.PS-OMW0002-C Piping Piping specification: -02 and -N02 After hand tightening, tighten the fitting using a spanner on the flat surfaces of the fitting. The tightening torque must be 8 to 12 Nm. Piping specification: -F02 After hand tightening, tighten the fitting using a spanner on the flat surfaces of the fitting.
Min. Dripping Flow Rate(l/min): 15, Oil Storage Capacity(cm3): 25, Case: [Resin] Polycarbonate Case, Inlet Side Connection Type: G, Inlet Side Plumbing Thread Nominal: 1/4, Outlet Side Connection Type: G, Outlet Side Plumbing Thread Nominal: 1/4, Drain Exhaust: [Not Provided] No Drain Cock, Flow Direction: [Right] From Left to Right, Size of Body: 20, Accessory: Without optional
Body Size: 20, Thread: F (G), Port Size: 02 (1/4), Mounting: None, Semi-Standard, Body Size 10: Standard, Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
, d e t e r i o r a t i o n o f a c c u r a c y, a n d breakage of parts.)
H E R M A N I F O L D O P T I O N S : L A T C H I N G S O L E N O I D T Y P E L A T C H I N G T Y P E V A L V E L A T C H I N G T Y P E V A L V E W I T H M A N U A L O V E R R I D E M A N I F O L D O P T I O N P A R T S A V A I L A B L E : P E R F E C T C H E C K B L O C K P E R F E C T C H E C K B L O C K W I T H V A L V E O R M A N I F O L D Courtesy of Steven Engineering, Inc. !
Connection 3.2, 4 6, 8, 10, 12, 16 KQ2 Nylon, Soft nylon, Polyurethane M5, M6, R 1/8 to 1/2 From 100 kPa One-touch fittings One-touch fittings/Manifold Series KM Applicable tubing: Nylon, Soft nylon, Polyurethane Tubing O.D.: 4, 6, 8, 10, 12 Port A piping port Port B port size No. of port A Piping specifications Port A Port B Model Model 4 6 8 8 10 12 Rc Rc 6 8 10 6, R 6, R 6, R 8, R 8, R
formula Inclination a Measurement related 2000 0x07D0 0 R F32 N Refer to table "Inclination and intercept to the unit specification".
1 8 R 1 4 R 3 8 04F 06F 08F 01S 02S 03S Red R (Option) 2(A) port size 04F 06F 08F 4 6 8 *Specifications and dimensions for the 90-series are the same as standard products.
To order a single push button for series VM1000 and a single cover use the part number below. VA VM Push button Cover for push button 3410701-R 3410703 (White only) Color Red 3410701-B Black 3410701-G Green VR VH VHS Removing the valve as a unit Mark Use your thumb to pry the button upwards. 5-6-7 Micro Mechanical Valve Series VM1000 Miniature stucture requires little mounting space.
(Page 11) 0x000C (12) 0 R/W Device Access Locks N 0x0010 (16) 0 R Vendor Name N SMC Corporation 0x0011 (17) 0 R Vendor Text N www.smcworld.com 0x0012 (18) 0 R Product Name N AMS-ITV 0x0013 (19) 0 R Product ID N AMS-IL 0x0014 (20) 0 R Product Text N AMS-ITV 0x0015 (21) 0 R Serial Number N "x" *3 0x0016 (22) 0 R Hardware Revision N HW-Vx.y *4 0x0017 (23) 0 R Software Revision N FW-Vx.y *4 "
(Page 14) 0x0025 (37) 1..11 R Detailed Device Status N *1: R means Read and W means Write. *2Y is included in data storage, N is not included in data storage. *3: 8 octets fixed character string. *4: "x" represents a major revision number.
*sure dlsplay Accuracy J3% (lull span) Minimum unit [ i l P a : 0 . 0 1 . k a f / c m ' : 0 . 0 1 , b a r : 0 . 0 1 .
Millirrfeter size 1{1' Q I1'SiZeJ' , 0.6' r'~ '" 0Ur 0~ '2. , ~1/4' a!;'16" 03/4" 'ol/2~ AsP330F'!U R(PT)1/8 M5 X 0.8 J\SP. 4;JOF~02 R(PT)I /4 Rc(PD1 /8 IIS'P530F:03 R(PT)318 Rc(PT)lIS 'ASi"!)30l"'lJ4 " R(PT)1!2 Rc(PT)1I4 ASP;l3OF:,FO~ RIPT)114 G(PF)1I8 I\Sps:ioFf;03' R(PT)318 G(PF)118 ),I'SPsJOF;;04: R(PT)1 /2 G{PF)1/4 A~P33!1F" 'l Il1 NPT1 /8 10-32UNF ,~Sp430FNO,?
The pressure in the pilot chamber e increases and operates on the upper surface of the diaphragm r. As a result, the air supply valve t linked to the diaphragm r opens, and a portion of the supply pressure becomes output pressure. This output pressure feeds back to the control circuit i via the pressure sensor u.