(Energized closed) Voltage 1 2 3 4 5 6 7 8 9 100V AC 50/60Hz 200V AC 50/60Hz 110V AC 50/60Hz 220V AC 50/60Hz 24V DC 12V DC 240V AC 50/60Hz 48V AC 50/60Hz Other (Contact SMC seprately) Options Standard F, G, L, T are available option. Refer to p.4.0-11 "Applicable Fluid Check List".
/Japanese 1pc.), Accessory Y strainer (40 meshes) 25A, Barrel nipple 25A Anchor brackets 2pcs.
0.000 20 40 60 0.000 25 50 75 100 125 Load [N] Load [N] Load [N] LESYH16 LESYH16 Lr = 120 mm LESYH16 0.50 0.3 0.08 Table displacement [mm] Table displacement [mm] Table displacement [mm] LESYH16 -100 LESYH16 -100 LESYH16 -100 0.40 0.06 0.2 0.30 LESYH16 -50 0.04 LESYH16 -50 0.20 LESYH16 -50 0.1 0.02 0.10 0.000 100 200 300 400 0.000 50 100 150 200 0.00 50 100 150 200 Load [N] Load [N] Load
VN Rated voltage 1 2 3 4 5 6 7 8 9 Solenoid valve option Nil Standard 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-10 by Applicable Fluids Check List for special fluids outside of the standard.
(English 1, Japanese 1), Operation Manual 2 copies (English 1, Japanese 1), Accessories Y strainer (40 mesh) 25A, Barrel nipple 25A, Anchor bracket 2 pcs.
(mm) Weight (g) Port size Effective area (mm2) 25 35 40 50 Thread (Nominal size) 1 (25A) 32A 40A 50A 1650 5400 6800 8400 0.02 225 415 560 880 VXED2260-10 VXED2270-32 VXED2380-40 VXED2390-50 1.5 1.0 Flange 0.03 Note) Weight of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively.
/Japanese 1pc.) 3 Y strainer (40meshes) 25A 1pc. 4 Barrel nipple 25A 1pc. 5 Anchor brackets The anchor bolts are not attached 2pc.
/Japanese 1 pc.), Y-strainer (40 meshes) 25A, Barrel nipple 25A, Anchor bolt fixing brackets 2 pcs.
VN Rated voltage 1 2 3 4 5 6 7 8 9 Solenoid valve option Nil Standard 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-10 by Applicable Fluids Check List for special fluids outside of the standard.
VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.
VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Electrical entry: D or DZ only Electrical entry: D or DZ only Coil rated voltage 1 2 3 Note 1) 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 4 Note 1) Manual override 5 6 Note 1) Non-locking push type Nil A Electrical entry CE-compliant G Non-locking push type
size (mm) Symbol Port size Rc 1 2 3 Note) 4 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz Symbol N.C. 1 MPa N.C. 0.5 MPa N.O.
Seal Coil voltage 1 100 VAC (50/60 Hz) 2 200 VAC (50/60 Hz) 3 110 VAC (50/60 Hz) 4 220 VAC (50/60 Hz) 5 24 VDC 6 12 VDC Series Enter in order starting from the first station on the D side.
Flow-rate Characteristics (Pressure Loss) PF3W711/511 PF3W721/521 0.04 0.04 Pressure loss [MPa] Pressure loss [MPa] 0.03 0.03 0.02 0.02 0.01 0.01 0 0 0 20 40 60 80 100 0 50 100 150 200 250 Flow rate [L/min] Flow rate [L/min] Straight Piping Length and Accuracy (Reference Value) Pressure: 0.3 MPa PF3W711/721/511/521 Piping diameter: 25A, 30A Straight piping length p10 p8 Accuracy [% F.S.]
Piping Port size Orifice diameter [mm] Thread type Pilot port size With/without silencer (Option) 3/4 (20A) 32 Without Compression fitting type 1 (25A) 40 Without Rc NPT G Direct piping type (Rc, NPT, G) 1/8 1/4 1 1/2 (40A) 50 With Immersion type 1 (25A) 40 Without CAT.ES70-57B JSXFA Series Pulse Valve Valve for Dust Collector JSXFA Series Long service life: 10 million cycles1 or more A spring
/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Symbol A: Non-locking push type A (projecting) N.C. 0.5 MPa N.O. 1 MPa N.C. 1 MPa 4 1 6A 8A 10A 10A 15A 20A 25A 32A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz 7 Valve size 1 5 6 24 VDC 12 VDC B: Slotted locking type B (tool required) 7 240 VAC 50/60 Hz 15 (11) 2 Semi-standard For other rated voltages, please consult with SMC. 20 (14) 3 25 (16) 4 1
/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Orifice dia.
B: Locking slotted type 4 1 6A 8A 10A 10A 15A 20A 25A 32A 40A 50A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz 10 5 6 24 VDC 12 VDC 240 VAC 50/60 Hz 7 15 2 9 Other Nil: Non-locking push type 20 3 Option Valve size 5 to 7 25 4 1 1 1 2 32 5 1 4 1 2 40 50 6 7 Note) Air operated only Electrical entry/ With light/surge voltage suppressor E GS G Grommet with surge voltage suppressor Grommet Grommet
Rc G NPT NPTF Nil F N T None With bracket Nil B Valve type 1 3 N.C./3.5 MPa N.C./7.0 MPa Electrical entry/With light/surge voltage suppressor D DIN terminal Seal material DZ DIN terminal with light/surge voltage suppressor A B NBR seals FKM seals Rated voltage Valve size Port size 3 2 1 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 10A 15A 20A 25A 1 2 3 4 3 8 1 2 3 4