of 20%, V 1120 [W] x 1.2 = 1344 [W] After 15 minutes, cool 32C down to 20C. * This is the calculated value by changing the fluid temperature only.
Note 3) The value at a temperature of 20C.
Metric sizes 6 8 10 12 ASS Flow rate l/min (ANR) Controlled 100 180 230 260 390 460 660 790 920 1580 1710 ASR (free) flow Effective area mm2 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are at a pressure of 0.5MPa, and temperature of 20C.
Note 2) Conditions: Set temperature 77F (25C), Facility water temperature 68F (20C), Facility water flow rate 2.1 gpm (8 L/min), Ambient temperature 77F (25C). Note 3) Conditions: Set temperature 77F (25C), Facility water temperature 68F (20C), Facility water flow rate 2.6 gpm (10 L/min), Ambient temperature 77F (25C).
Cooled substance total volume V Cooling time h Cooling temperature difference T Facility water temperature Circulating fluid : 60 L : 15 min : 20C (20 K) (70C 50C 20C) : 20C (293.15 K) : Fluorinated fluid Density : 1.74 x 103 kg/m3 Example of conventional measurement units (Reference) 0.06 m3 0.25 h 20C 20C Fluorinated fluid Density : 1.74 x 103 kg/m3 Specific heat C: 1.05 x 103 J/(kgK)
E.g.: TEMP SP value: +20C, OFFSET value: +2C Circulating fluid discharge temp.: +22C, TEMP PV: +20C When OFF is selected If no mode is selected, temperature control is conducted to allow the discharge temperature of the circulating fluid to be TEMP SP value.
fluid temperature: CH1: 20C/CH2: 25C at the device outlet. *6 Fluid flow rate to maintain the cooling capacity.
TISA01BU-20X4 Made to Order eThe value of the min. bending radius is at a temperature of 20C and O.D. variable rate 10% max.
20C and when the rated voltage is applied.
(mm) Applicable cylinder bore size (mm) 6, 10, 16, 20 20, 25, 32 20, 25, 32, 40 40, 50, 63 63, 80, 100 Release button color: Light gray 4 6 8 10 12 AS121FP-M5 AS221FP-01 AS221FP-02 AS321FP-03 AS421FP-04 M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 Specifications Air Grade 1 (1) Fluid Particulate generation grade Proof pressure (20C) Maximum operating pressure (20C) Minimum operating pressure Ambient
Specifications Grade 1 Note 1) Particulate generation grade Air, Nitrogen gas, Water (pure water) Note 2) Fluid 1MPa (145 psi) Note 3) Max operating pressure 20C (68F) 100kPa (-14.5 psi) Operating vacuum pressure Caution 3MPa (435 psi) Proof pressure 20C (68F) 20C to 80C (-4 to 176F) Ambient and fluid temperature Series KP is a line of special One-touch fittings for use in clean room blow
Specifications Grade 1 Note 1) Particulate generation grade Air, Nitrogen gas, Water (pure water) Note 2) Fluid 1MPa (145 psi) Note 3) Max operating pressure 20C (68F) 100kPa (-14.5 psi) Operating vacuum pressure Caution 3MPa (435 psi) Proof pressure 20C (68F) 20C to 80C (-4 to 176F) Ambient and fluid temperature Series KP is a line of special One-touch fittings for use in clean room blow
Specifications Grade 1 Note 1) Particulate generation grade Air, Nitrogen gas, Water (pure water) Note 2) Fluid 1MPa Note 3) Maximum operating pressure (20C) 100kPa Operating vacuum pressure Caution 3MPa Proof pressure (20C) 20C to 80C Ambient and fluid temperature Series KP is a line of special One-touch fittings for use in clean room blowing and washing lines.
The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure below. Fluid Air/Water Max. operating pressure at 20C 0.8 MPa Burst pressure Refer to the burst pressure characteristics curve. One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Applicable fittings Bend the tube into U-form at a temperature of 20C.
Note 3) The value at ambient temperature of 68F (20C) and when the rated voltage is applied. The value depends on the ambient environment. This is for reference. Note 1) Apparent power: The value at ambient temperature of 68F (20C) and when the rated voltage is applied.
Fixed end At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameters rate of change is 5%. Max.
) 2.0 (at 20C) 4.0 (at 20C) 8.0 (at 20C) 2.0 (at 20C) 8.0 (at 20C) 4.0 (at 10C) 8.0 (at 10C) 2.8 (at 10C) 3.2 (at 10C) 2.3 (at 20C) 2.6 (at 20C) 2.8 (at 20C) 3.0 (at 20C) 2.3 (at 20C) 3.3 (at 20C) 3.6 (at 10C) 5.9 (at 10C) Cooling capacity Note 3) (kW) Heating capacity Note 3) (kW) Temp. stability Note 4) (C) 0.1 Pump capacity Note 5) (50/60 Hz) (MPa) 0.45/0.65 (at 20 l/min) 0.45/0.65 (at
Safety standards CE marking, UL (NRTL) standards *1 Conditions: Circulating fluid set temperature 20C, Flow rate 3 L/min, Facility water temperature 20C, Flow rate 10 L/min, Ambient temperature 25C *2 The indicated values are with a stable load without turbulence in the operating conditions.
E.g.: TEMP SP value: +20C, OFFSET value: +2C Circulating fluid discharge temp.: +20C, TEMP PV: +20C When OFF is selected If no mode is selected, temperature control is conducted to allow the discharge temperature of the circulating fluid to be TEMP SP value.
After 15 minutes, cool 32C down to 20C.