SMC Corporation of America
Elite Part Number Search
Search Results "25A-CXSM25-100"

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.  25A-PF3W7 is a digital flow sensor that constantly monitors water or coolant flow.  The upgraded 2-screen, 3-color numerical display rotates in both CW and CCW directions, offering improved visibility in a range of orientations. 

Non-rotating accuracy ranging from +/-0.02° for 100 mm bore to +/-0.07° for 20 mm bore. The 25A-MGGL series is designed using materials compatible with secondary battery applications and are able to be used in low dew point environments. 

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure

CAT.ES11-80 A 5-Port Solenoid Valve Series VQC NEW CONCEPT Connector Type Manifold Series VQC1000/2000/4000 Outstanding response times and long life Conforming to IP67 for protection from dust and moisture (Metal seal: Single type with light and surge suppressor) VQC1100: 10ms 2ms; 200 million cycles VQC2100: 20ms 2ms; 200 million cycles VQC4100: 17ms 3ms; 100 million cycles (Based on IEC529

/Japanese 1 pc.), Y-strainer (40 meshes) 25A, Barrel nipple 25A, Anchor bolt xing brackets 2 pcs. (including 6 M8 bolts) Note 10) Weight (dry state) kg Approx. 180 Approx. 215 Approx. 280 Note 1) When the ambient temperature or circulating uid temperature is 10C or below, refer to "Operation at low ambient temperature or low circulating uid temperature" (page 186-1).

Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Series 25A-CY3B is compatible with secondary battery applications

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.   25A-PFM7 is a digital flow sensor compatible with air, nitrogen, argon and carbon dioxide. The 3-digit LED display can be red or green, changing when a set point is reached.  Either instantaneous or accumulated flow can be shown. 

Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Direct mount type; Auto switch capable; Series 25A-CY3R is compatible with secondary battery applications

Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15~0.20 MPa (22~29 psi); Speed: 80~500 mm/sec (MY3A), 80~1000 mm/sec (MY3B), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3* is compatible with secondary battery applications

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.   25A-PFM7 is a digital flow sensor compatible with air, nitrogen, argon and carbon dioxide. The 3-digit LED display can be red or green, changing when a set point is reached.  Either instantaneous or accumulated flow can be shown. 

Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Series 25A-CY3B is compatible with secondary battery applications

Bore sizes (mm): 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths (mm): 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Direct mount type; Auto switch capable; Series 25A-CY3R is compatible with secondary battery applications

Fluid: air; Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC; Base mounted or Body ported; Ambient & fluid temperature: 50°C; Series 25A-SY5000/7000 is compatible with secondary battery applications

Bore sizes: 16, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000 mm; Minimum operating pressure: 0.15~0.20 MPa (22~29 psi); Speed: 80~500 mm/sec (MY3A), 80~1000 mm/sec (MY3B), 80~1500 mm/sec (external shock absorber); Auto switch capable; Series 25A-MY3* is compatible with secondary battery applications

Series 25A-AV-A soft start-up valves allow the user to set the initial rate of system pressurization to minimize system shock. The 25A specifies that this product is compatible with secondary battery. When deactivated, the valve quickly exhausts the system for safe servicing of equipment.

30 st to 100 st Over 100 st to 200 st Over 200 st to 300 st 30 st or less Over 300 st Over 25 st to 100 st Over 100 st to 200 st Over 200 st to 300 st 25 st or less Over 300 st Over 30 st to 100 st Over 100 st to 200 st Over 200 st to 300 st 30 st or less 28 52 300 100 75 77 128 200 128 178 24 52 174 198 42 54 92 80 14.5 25.5 74 28 156 180 140 17.5 M12 x 1.75 32 40 50 63 117 117 12 16