Series: 25A-PF3W7, Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature:

Series: 25A-PF3W7, Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: Â

Series: 25A-PF3W7, Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: D (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature

Series: 25A-PF3W7, Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: Â

Series: 25A-PF3W7, Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °

For the AQ240F, there are ø4, ø6, or ø1/4 One-touch fittings, and for the AQ340F, there are ø6 or ø1/4 One-touch fittings. ø8 One-touch fittings are available as a special order. (e.g., AQ340F-08-00-X512, etc.) Consult your local SMC sales office for further details. The AQ240F/340F series catalog can be found here.

Note 3) ZP3B-T2B(JB/K)20-B5 ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-T(04/06/08)UM;(J/K)3-@ ZP3-T(04/06/08)B;(J/K)3-@ ZP3-T(04/06/08)UM;(J/K)6-@ ZP3-T(04/06/08)B;(J/K)6-@ ZP3-T(04/06/08)UM;(J/K)10-@ ZP3-T(04/06/08)B;(J/K)10-@ ZP3-T(04/06/08)UM;(JB/K)15-

Note 3) ZP3B-T2B(JB/K)20-B5 ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-T(04/06/08)UM;(J/K)3-@ ZP3-T(04/06/08)B;(J/K)3-@ ZP3-T(04/06/08)UM;(J/K)6-@ ZP3-T(04/06/08)B;(J/K)6-@ ZP3-T(04/06/08)UM;(J/K)10-@ ZP3-T(04/06/08)B;(J/K)10-@ ZP3-T(04/06/08)UM;(JB/K)15-

D 02 1.2 M4 x 0.7 4 04 1.6 06 08 2.5 28.4 N S U F GN GS B4 M5 x 0.8 19.5 04 06 ZP R U 02 1.2 M5 x 0.8 5 04 1.6 06 08 2.5 B5 A2 Dimensions Per Vacuum Inlet Construction p. 115 Model Adapter Assembly p. 122 D E F Fitting part min. hole size Vacuum inlet direction q Pad dia.

Note 3) ZP3B-T2B(JB/K)20-B5 ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-T(04/06/08)UM;(J/K)3-@ ZP3-T(04/06/08)B;(J/K)3-@ ZP3-T(04/06/08)UM;(J/K)6-@ ZP3-T(04/06/08)B;(J/K)6-@ ZP3-T(04/06/08)UM;(J/K)10-@ ZP3-T(04/06/08)B;(J/K)10-@ ZP3-T(04/06/08)UM;(JB/K)15-

Model Meter-out type Rod and applicable tubing O.D. 4 6 ) ) 8 ) 10 ) Meter-in type AS1000P-04-04 AS2000P-04-04 AS2000P-06-06 AS2500P-06-06 AS3000P-08-08 AS3000P-10-10 AS1010P-04-04 AS2010P-04-04 AS2010P-06-06 AS2510P-06-06 AS3010P-08-08 AS3010P-10-10 ) ) The lock nut provides identification.

Note 3) ZP3B-T2B(JB/K)20-B5 ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-T(04/06/08)UM;(J/K)3-@ ZP3-T(04/06/08)B;(J/K)3-@ ZP3-T(04/06/08)UM;(J/K)6-@ ZP3-T(04/06/08)B;(J/K)6-@ ZP3-T(04/06/08)UM;(J/K)10-@ ZP3-T(04/06/08)B;(J/K)10-@ ZP3-T(04/06/08)UM;(JB/K)15-

Note 3) ZP3B-T2B(JB/K)20-B5 ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-T(04/06/08)UM;(J/K)3-@ ZP3-T(04/06/08)B;(J/K)3-@ ZP3-T(04/06/08)UM;(J/K)6-@ ZP3-T(04/06/08)B;(J/K)6-@ ZP3-T(04/06/08)UM;(J/K)10-@ ZP3-T(04/06/08)B;(J/K)10-@ ZP3-T(04/06/08)UM;(JB/K)15-

Note 3) ZP3B-T2B(JB/K)20-B5 ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-T(04/06/08)UM;(J/K)3-@ ZP3-T(04/06/08)B;(J/K)3-@ ZP3-T(04/06/08)UM;(J/K)6-@ ZP3-T(04/06/08)B;(J/K)6-@ ZP3-T(04/06/08)UM;(J/K)10-@ ZP3-T(04/06/08)B;(J/K)10-@ ZP3-T(04/06/08)UM;(JB/K)15-

(Option ) Multi-connector Socket side only Plug side only DMK6-23 DMK6S-23 DMK6P-23 6 DMK-C-6 DMK6-04 DMK6S-04 DMK6P-04 DMK12-23 DMK12S-23 DMK12P-23 12 DMK-C-12 DMK12-04 DMK12S-04 DMK12P-04 Specifications Applicable tubing materials Nylon, Soft nylon, Polyurethane Applicable tubing O.D.

For AC2030 For AC2530 For AC3030 For AC4030 For AC4030-06 Model Description 02 03 04 06 E50-06 E2001 02 03 E3002 03 04 E3002 03 04 E40Piping adapter 02 03 04 4 4 4 06 4 IS1000EY 01 02 03 2 2 2 Y IS1000E02 03 04 3 3 3 Y IS1000E02 03 04 3 3 3 Y IS1000EY54-03 04 Attachment Accessory Pressure switch with piping adapter IS1000M-2Y IS1000M-3Y IS1000M-3Y IS1000M-4Y IS1000M-5Y Y21-01 (02) Y31-02

(Option ) Multi-connector Socket side only Plug side only DMK6-23 DMK6S-23 DMK6P-23 6 DMK-C-6 DMK6-04 DMK6S-04 DMK6P-04 DMK12-23 DMK12S-23 DMK12P-23 12 DMK-C-12 DMK12-04 DMK12S-04 DMK12P-04 Specifications Applicable tubing materials Nylon, Soft nylon, Polyurethane Applicable tubing O.D.

Form w 1 Material e r Vacuum inlet Connection thread N S U F GN GS HS 04 06 08 UM 02 10.8 7 2 1.4 KQ2H02-M5N C2 04 14.7 8 4 2.5 KQ2H04-M5N ZP3 Y B3 02 10.8 7 2 1.4 KQ2H02-M5N 04 14.7 8 4 2.5 KQ2H04-M5N 06 10 6 KQ2H06-M5N Vacuum inlet: One-touch fitting 10 13 16 Applicable tubing O.D.

) 06 (10) Y610(03) 04 (03) 04 Y610(5) (6) VHS40-06 02 03 04 E600(6) VHS2001 02 02 03 02 03 VHS30VHS30VHS40VHS50E30002 03 04 E30002 03 04 E40002 03 04 06 E500-06 E20001 02 03 (6) 06 10 06 10 E60006 10 E600E100-M5 (6) 02 03 04 06 IS1000E-30 IS1000E-30 02 03 04 IS1000E-20 01 02 03 Pressure switch with piping adapter 02 03 04 IS1000E-40 (6) Y24-01 02 Y34-01 02 Y34-01 02 Y44-02 03 Y54-03 04 Y14

-03 AMD150-03 1.5 0.2 HAA7-06 HAW2-04 AT6C-04 AFF2B-03 IDF2D-1 AM150-03 AMD150-03 2.2 0.3 HAA7-06 HAW7-06 AT6C-04 AFF2B-03 IDF3DAM150-03 AMD250-03 3.7 0.5 HAA7-06 HAW7-06 AT6C-04 AFF4B-03 IDF4DAM250-03 AMD250-03 5.5 0.7 HAA7-06 HAW7-06 AT6C-04 AFF4B-04 IDF6DAM250-04 AMD350-04 7.5 1.0 HAA15-10 HAW22-14 AT11C-06 AFF8B-04 IDF8DAM350-04 AMD350-04 11 1.5 HAA15-10 HAW22-14 AT11C-06 AFF8B-06 IDF11CAM350