14.5 17 285.5 275 254.5 15.5 18 298 287.5 265 16.5 19 310.5 300 275.5 17.5 20 310.5 300 286 12.5 L1 L2 L3 L4 External Pilot Manifold L Dimension n: Stations L n 2 135.5 125 107.5 14 16 285.5 275 254.5 15.5 3 148 137.5 118 15 4 160.5 150 128.5 16 5 173 162.5 139 17 6 173 162.5 149.5 12 7 185.5 175 160 13 8 198 187.5 170.5 14 9 210.5 200 181 15 10 223 212.5 191.5 16 11 235.5 225 202 17 12
fitting dimensions Secure mounting of n (2 or more) switches (horizontal) 1 pc. 24 or more 31 0 0.4 31 x n pcs. + 3.5 x (n pcs. 1) 31 0 0.4 31 0 0.4 4 x R2 or less 4 x R2 or less Secure mounting of n (2 or more) switches (vertical) 24 or more 31 0 0.4 31 x n pcs. + 3.5 x (n pcs. 1) 4 x R2 or less Note) If a bend (R) is used, limit it to R2 or less.
11 11 11 39 63 68 69 96 95 110 Note 1) Dimension E applies when heater option is included.
light 50 11 (12.5) 11 (12.5) 2 4 4(A) port 2(B) port 24.6 38 48 4 2 B A 24.6 A B 38 48 14 12 5 3 1 B A 30 45 14 3 5 1 12 2-5.6 Mounting hole Manual override 2-5.6 Mounting hole 45 30 Manual override 14.5 27 30.5 32 41.5 91.5 129 79 PE X PE X 32 41.5 30.5 27 R1 R2 P R2 R1 14.5 P 19.5 19.5 (21) (21) Rc 1/8 External pilot port Rc 1/8 PE port Rc 1/8 PE port 19.5 (21) 19.5 (21) 31 31 5-Rc 1/4
Dimensions (mm) Equation L1=10.5n+14.5, L2=10.5n+25 n: Station (Max.16) n L 1 2 46 56.5 225 235.5 6 88 98.5 262.5 273 3 56.5 67 237.5 248 7 98.5 109 275 285.5 4 67 77.5 250 260.5 8 109 119.5 287.5 298 5 77.5 88 250 260.5 9 119.5 130 300 310.5 10 130 140.5 312.5 323 14 172 182.5 350 360.5 11 140.5 151 312.5 323 15 182.5 193 362.5 373 12 151 161.5 325 335.5 16 13 161.5 172 337.5 348 L1 L2 L3
Description Qty. 4 4 4 4 1 1 1 1 Seal Seal Seal Seal 11 11 11 11 1 1 1 1 Gasket Gasket Gasket Gasket Parts included in seal kit 12 12 12 12 1 1 1 1 Gasket Gasket Gasket Gasket 16 16 16 16 Wear ring Wear ring Wear ring Wear ring 4 4 4 4 17 17 17 17 Piston seal Piston seal Piston seal Piston seal 4 4 4 4 26 26 26 26 Seal washer Seal washer Seal washer Seal washer 2 2 2 2 A set includes all
Large size IDFAF Series Outlet air pressure dew point Page Model Rated inlet condition Air flow capacity (m3/h [ANR]) Port size IDFA100F-38 960 R2 40C IDFA125F-38 10C 1210 R2 1/2 0.7 MPa IDFA150F-38 1500 DIN flange 80 P. 98 to 100 IDFA100F-40 860 R2 35C IDFA125F-40 3C 1100 R2 1/2 0.7 MPa IDFA150F-40 1340 DIN flange 80 3.
Note 3) When two or more symbols are specified, indicate them alphabetically. 3 m 2-6-11 Base Mounted 12 Series VQ5000 Kit (D-sub Connector kit) F Applicable connector: D sub connector (25P) (Conforming to MIL-C-24308) 83 29.5 29.5 2-Rc 1/8 (Pilot EXH port) 12 21 47.5 36 5 R1 PE 3 R2 1 P SMC 6-Rc 3/4 (P), 5(R1), 3(R2) port Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco
49 12.5 (F) (T) (F) (T) VV802-R-01 (Size 18 mm) 18 9 1/8" VV801-R-03 (Size 26 mm) By mounting individual EXH spacers on a manifold block, it is possible to provide individual EXH ports for each valve. (3(R2), 5(R1) common EXH type) 22.5 11 Size 18 mm 1(P) 129.5 4(A) 61 2(B) 3(R') 19 26 13 3/8" 5(R1) 3(R2) Circuit diagram 28.6 14.3 Size 26 mm 23 Series VS 8-2/VS 8-4 S R S R Conforms to ISO
) (12.5) 11(B port) (12.5) Indicator light Indicator light 167 181 59 73 50 90 108 2 4 24.6 38 48 11 (A port) 11 (B port) B A (12.5) (12.5) 14 12 1 5 3 4 2 Manual override 30 45 24.6 A B 25.6 Mounting hole 38 48 B A 14 5 3 1 12 30 45 25.6 Mounting hole Manual override 14.5 27 30.5 32 41.5 91.5 129 G1/2 Electrical entry 79 PE X 41.5 32 30.5 X PE 27 R1 R2 P 15.5 14.5 R1 R2 P 15.5 Rc1/8 External
) 01 02 01 02 300 (Lead wire length) 300 DIN terminal (D) VZ5140-D: With light/surge voltage suppressor 01 02 MAX. 10 Applicable cable O.D. 3.5 to 7 3-3-71 Series VZ5000 2 Position Double VZ5240 Grommet (G), (H) VZ5240G H 01 02 Manual override (Non-locking) (Mounting hole) (Lead wire length) G: 300 mm H: 600 mm (PE port) 3-Rc 1/8, 1/4 (1(P), 4(A), 2(B) port) 2-Rc 1/4 (5(R1), 3(R2) port) L
Input time 30 ms or longer Reference condition*11 Select from Standard condition or Normal condition.
11 M5x0.8 20 106 35 25 ~300 19.5 22 16.5 10 14 2 12 12 31 M5x0.8 Depth 7.5 5 8 M10x1.25 29 18 69 11 11 M6x0.75 25 111 40 32 ~300 19.5 22 20 12 18 2 12 11 38 M5x0.8 Depth 8 5.5 10 M10x1.25 36 18 71 11 10 M8x1.0 40 32 113 40 ~300 27 30 26 16 25 2 13 12 47 M6x1 Depth 12 6 14 M14x1.5 44 18 78 12 10 M10x1.25 50 40 130 50 ~300 32 35 32 20 30 2 14 13 58 M8x1.25 Depth 16 7 18 M18x1.5 55 14 90 13
11 M5x0.8 20 106 35 25 ~300 19.5 22 16.5 10 14 2 12 12 31 M5x0.8 Depth 7.5 5 8 M10x1.25 29 18 69 11 11 M6x0.75 25 111 40 32 ~300 19.5 22 20 12 18 2 12 11 38 M5x0.8 Depth 8 5.5 10 M10x1.25 36 18 71 11 10 M8x1.0 40 32 113 40 ~300 27 30 26 16 25 2 13 12 47 M6x1 Depth 12 6 14 M14x1.5 44 18 78 12 10 M10x1.25 50 40 130 50 ~300 32 35 32 20 30 2 14 13 58 M8x1.25 Depth 16 7 18 M18x1.5 55 14 90 13
-6 = 9.0 x 10-6 (kgm2) Moment of inertia around Z axis IA = IZ1 + m1r12 X 10-6 z r2 Z2 B part r2 = 47(mm) Calculation of weight m2 = d x e x f x Specific gravity m2 = 5 x 10 x 12 x 2.7 x 10-6 = 0.002 (kg) Moment of inertia around Z2 axis IZ2 = {m2 (d2 + e2)/12} x 10-6 IZ2 = {0.002 x (52 + 102)/12} x 10-6 = 0.02 x 10-6 (kgm2) IB = 0.02 x 10-6 + 0.002 x 472 x 10-6 = 4.4 x 10-6 (kgm2) I =
-6 = 9.0 x 10-6 (kgm2) Moment of inertia around Z axis IA = IZ1 + m1r12 X 10-6 z r2 Z2 B part r2 = 47(mm) Calculation of weight m2 = d x e x f x Specific gravity m2 = 5 x 10 x 12 x 2.7 x 10-6 = 0.002 (kg) Moment of inertia around Z2 axis IZ2 = {m2 (d2 + e2)/12} x 10-6 IZ2 = {0.002 x (52 + 102)/12} x 10-6 = 0.02 x 10-6 (kgm2) IB = 0.02 x 10-6 + 0.002 x 472 x 10-6 = 4.4 x 10-6 (kgm2) I =
ZX1-R1 R2 R3 R4 R5 R6 R7 R8 Symbol Part no. ZX1-R 9 R10 R11 R12 R13 R14 R15 R16 PS PS PS PS PV PV PV PV PV PV PV PV R1 R2 R3 R4 R5 R6 R7 R8 R 9 R10 R11 R12 R13 R14 R15 R16 PE PE Caution when ordering manifold PD PD PD PD PE PE The asterisk denotes the symbol for assembly. Prefix it to the ejector part numbers to be mounted.
20 33.5 5.5 M10 X 1.25 1 to 300 19.5 17 6 M26 X 1.5 137 146 30 15 30 9 14 22 30 62 9 10 10 13 25 8 45 26 34.5 37.5 5.5 M10 X 1.25 1 to 300 19.5 17 6 M26 X 1.5 139 148 30 15 9 14 22 30 64 9 10 12 13 32 8 45 26 21 7 M14 X 1.5 21.5 M32 X 2 42.5 46.5 1 to 300 22 8 177 188 39 11 18 24 38 88 10 15 14 16 40 11 50 32 With rod boot (mm) Symbol Z h l Stroke f e 1 to 50 51 to 100 1 to 50 51 to 100
750 20 to 550 10 to 300 Actuator specifications 451 to 500 10 to 600 5 to 300 20 to 900 12 to 600 6 to 300 24 to 800 16 to 650 8 to 325 30 to 750 20 to 550 10 to 300 501 to 600 20 to 900 12 to 540 6 to 270 24 to 800 16 to 650 8 to 325 30 to 750 20 to 550 10 to 300 601 to 700 20 to 630 12 to 420 6 to 230 24 to 800 16 to 620 8 to 310 30 to 750 20 to 550 10 to 300 Parallel Stroke range
switch setting Turn ON No. 2 and No. 5, and (a) 24 VDC +/10% R2 = 1.5 k turn OFF the others.