1/8 FGX-OM-L011 SMC FGG FGG 20A P23 P4 P5 P5 P5 P67 2/8 FGX-OM-L011 FGG Series/ (P) 0.02MPa V V () O O 1 (O ) ) 3/8 FGX-OM-L011 FGG Series/ IN/OUT 0.1MPa M12 , INLETOUTLET 67 O V O 40 4/8 FGX-OM-L011 1 1/8 Rc2 Rp1/4 Rp1/4 INLET DRAIN Rp3/4 OUTLET Rc2 1 AG-10S SUS304 JIS B2401-1A-P11 NBR O JIS B2401-4D-P11 FKM M101.5 11 SUS304 M10 SUS304 SUS304 AN-3S SUS316WPA

Stainless Steel Heat Exchanger Type Air Dryer Series IDUS Series IDUS Inlet air temperature C Model IDUS3E IDUS4E IDUS6E 500 310 55 740 Air flow capacity l/mim(ANR) 295 (300) 475 (430) 703 (640) 60 160 275 225 55 Power consumption W 165 (189) 230 (275) 280 (295) 60 ( ): Previous model IDU3D/4D/6D Series IDFS Series IDFS Inlet air temperature C Model IDFS6E IDFS8E IDFS11E 740 35 1200 1650

VA-4D OMRON Corp. XN2A-1430 OMRON Corp. XS2 M12 4 Yamatake Co.,Ltd. PA5-4I Hirose Electric Co., Ltd. HR24 DKK Ltd. CM01-8DP4S Panel mounting Note Part no. Description Note Pin no.

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 10mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 15mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 8mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 10mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 8mm, Action: S (Single Acting Spring Return), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 15mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 4mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 6, Stroke: 15mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 6, Stroke: 8mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 6, Stroke: 6mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 6, Stroke: 10mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 6, Stroke: 8mm, Action: Single Acting Spring Return, Rod End Thread: Rod End Male Thread, Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 6, Stroke: 15mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 4, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: None, Auto Switches: F8N,

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: None, Auto Switches: F8N,