SMC Corporation of America
Elite Part Number Search
Search Results "10-VQD1151-5L-M5"

Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VQD1151 NO SIZE RATING, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 25, VQD1151 NO SIZE RATING, 0.15156 lb

Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VQD1151 OTHER SIZE RATING, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 1D, VQD1151 OTHER SIZE RATING, 0.16534

Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VQD1151 NO SIZE RATING, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 2D, VQD1151 NO SIZE RATING, 0.11098 lb

Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VQD1151 NO SIZE RATING, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 2D, VQD1151 NO SIZE RATING, 0.22046 lb

Body: 5 (Base Mounted), Valve Option: Standard, Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Connector, w/o Lead Wire)

Body: 5 (Base Mounted), Valve Option: Standard, Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector, w/Lead Wire)

Body: 5 (Base Mounted), Valve Option: Standard, Voltage: 5 (24 VDC), Electrical Entry: MO (M Plug Connector, w/o Lead Wire)

Please contact us for the latest version.sales@ocaire.com, MANIFOLD BASE, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 21, VQD1151 NO SIZE RATING, .00000 lb, ModelPort sizeMass (Bottom ported)Mass (Rear ported)Leakage02R1/4117 g89 g1 x 10?5 Pa?m3/sN02NPT1/4118 g90 gC01Rc1/8114 g86 g1 x 10?5 Pa?m3/s

Right angle, 5 m With mounting screw 2 pcs. 16-8-17 18 Series ISA2 DIN Rail ISA-5L Applicable models L 4.5 8 1.25 7.5 Part no.

Measure the amount of clean water which is dispensed 10 times continuously and convert it to one shot of dispensed volume. Repeat this measurement 10 times, and indicate the difference (%) between the average value of 10 sets of data (converted value of one shot) and the maximum and minimum values.

Specifications ISA2-G1 ISA2-G5 ISA2-H1 ISA2-H5 Model Detection distance Fluid Operating pressure range Recommended detection nozzle 0.01 to 0.25 mm 0.03 to 0.50 mm Dry air (filtered to 5 m) 30 to 200 kPa 1.5 5 or less 8 or less 12 or less 50 to 200 kPa 2.0 10 or less 15 or less 22 or less 50 kPa 100 kPa 200 kPa Supply pressure Consumption flow rate L/min (ANR) 12 to 24 VDC 10%, Ripple (p-p

IP8000 IP8100 Type Item Lever type lever feedback Rotary type cam feedback Single action Double action Single action Double action Input current Input resistance Supply air pressure Standard stroke Sensitivity Linearity Hysteresis Repeatability Coefficient of temperature 4 to 20mADC Note 1) 23515 (4 to 20mADC) 0.14 to 0.7MPa 10 to 85mm (Deflection angle 10 to 30) 60 to 100 Note 2) Within

No.IP80-OM00019-B / / * 3-4 5 1. 5 2. 6-7 2-1 IP8000 6 2-2 IP8100 7 3. 8-9 3-1 IP8000 8 3-2 IP8100 9 4. 10-12 5. 13 5-1 13 5-2 13 6. 14 7. 15-17 7-1 16 7-2 17 7-3 17 8. 18 9. 18-20 10. 20-22 11. 23-25 11-1 23 11-2 IP8100 23 11-3 IP8000 24 11-4 24 11-5 25 12. 26 13. 27-33 2 A (ISO/IEC)(JIS)*1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic

Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VALVE, BASE MT (DC), VALVE, VQD1151 VALVE, SOL 4/5-PORT, 2D, VQD1151 NO SIZE RATING, .09523

Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VALVE, BASE MT, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 2D, VQD1151 NO SIZE RATING, .06600 lb

Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50 C, VALVE, SOL, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 15, VQD1151 OTHER SIZE RATING, 0.46096 lb

Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VALVE, BASE MT, CLEAN ROOM, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 25, VQD1151 NO SIZE RATING, .13778