This is a legacy product, and replaced byCDG1UA40TN-50Z-XC6, CYL, AIR, DBL ACTING, S.S. ROD, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, MC, 40MM CG OTHERS (COMBO), 2.07865 lb
Part number example:
Old: CDG1DN20-50
New: CDG1DN20-50Z
Mounting: B (Basic, Double-side Bossed), Bore: 20mm, Stroke: 50mm, Cushion: None, Rod End Thread: Male Rod Thread, Pivot Bracket: None, Rod End Bracket: None, Temperature Options: XB6 (Heat Resistant, -10 to 150°C)
Mounting: B (Basic, Double-side Bossed), Bore: 20mm, Stroke: 50mm, Cushion: None, Rod End Thread: Male Rod Thread, Pivot Bracket: None, Rod End Bracket: None, Temperature Options: XB7 (Cold Resistant, -40 to 70°C)
(Or None in the Case of No Switch), Stroke Options: XB9 (Low Speed, 10 to 50mm/s)
Magnet: None, Mounting: B (Basic, Double-side Bossed), Bore Size: 20mm, Port Thread: Rc, Stroke A: 50mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: Rubber Bumper, Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch
Magnet: None, Mounting: B (Basic, Double-side Bossed), Bore Size: 20mm, Port Thread: Rc, Stroke A: 50mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: Rubber Bumper, Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch
Magnet: None, Mounting: B (Basic, Double-side Bossed), Bore Size: 20mm, Port Thread: Rc, Stroke A: 50mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: Rubber Bumper, Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch
Magnet: None, Mounting: B (Basic, Double-side Bossed), Bore Size: 20mm, Port Thread: Rc, Stroke A: 50mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: Rubber Bumper, Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch
Magnet: None, Mounting: B (Basic, Double-side Bossed), Bore Size: 20mm, Port Thread: Rc, Stroke A: 50mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: None, Stroke B: None, Cushion: Rubber Bumper, Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch
Magnet: None, Mounting: B (Basic, Double-side Bossed), Bore: 20mm, Port Thread: Rc, Stroke: 50mm, Cushion: None, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC22 (Fluororubber
Magnet: None, Mounting: B (Basic, Double-side Bossed), Bore: 20mm, Port Thread: Rc, Stroke: 50mm, Cushion: None, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC4 (w/Heavy Duty
Magnet: None, Mounting: B (Basic, Double-side Bossed), Bore: 20mm, Port Thread: Rc, Stroke: 50mm, Cushion: None, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel
Magnet: None, Mounting: B (Basic, Double-side Bossed), Bore: 20mm, Port Thread: Rc, Stroke: 50mm, Cushion: None, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC35 (w/Coil Scrapper
Magnet: None, Type: Pneumatic, Mounting: B (Basic), Bore: 20mm, Port Thread: Rc, Stroke: 50mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: W (Double Knuckle Joint)
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread type
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Heat Resistant, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -40~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread type
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread type
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread type