Output deviation (%F.S.) 0.5 0.5 Out VE 40 0 0 Return VY G 60 0.5 0.5 AL 80 1.0 1 0 2 4 6 8 10 0 25 50 75 100 0 25 50 75 100 Input signal (%F.S.) Input signal (%F.S.)
To mount ghl angle lype, be cedain 10 check that no possible ntefence occurs.
A B Press the or button to change the set value. The button is to increase and the button is to decrease the set value. 2 B D D Press the button continuously to keep increasing the set value.
Lock keys ( ref er t o P8) M i ni m um pressure ( F_1) adj ust i ng range M axi m um pressure ( F_2) adj ust i ng range 90% 100% 120% 100% 0% 0% 10% 20% 20m A 20m A 5V 10V 20m A 20m A 5V 10V 4 0 0 0 12 10 2. 5 5 4 0 0 0 12 10 2. 5 5 ( N ot e 1) : F_1 i s adj ust abl e i n a range f rom 20% t o 90% of t he rat ed val ue. ( D EFAU LT VALU E: 0% ) ( N ot e 2) : The pressure of l ess t han 0%
Specifications Model ISE35 Rated pressure range 0 to 1 MPa Display/setting pressure range 0.1 to 1 MPa ZSE20 ISE20 Withstand pressure 1.5 MPa ZSE30 ISE30 Minimum display/setting unit 0.01 MPa Applicable fluid Air, Non-corrosive gas, Non-flammable gas ZSE40 ISE40 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection) Power supply voltage ZSE10 ISE10 Current consumption
Plate Cylinder: Double Acting, Single Rod 25, 32, 40, 50, 63 Series MU How to Order B 25 D 30 M Z MU B 25 D 30 Z M S M9BW MDU With auto switch With auto switch (Built-in magnet) Number of auto switches Nil S n 2 pcs. 1 pc. n pcs. Mounting B L F G C D Basic Foot Rod flange Head flange Single clevis Double clevis Auto switch Nil Refer to the below table for applicable auto switch models.
F_1 and F_2 have setting ranges of 0-90%F.S. and 10-120%F.S., respectively. However, the set pressure exceeds rated output; 100F.S. is out of warranty. (refer to Fig.2,3) The values are necessary to satisfy F_1 + 10%F.S. < F2. If not, the previous values are reflected in this function. Default of Zero adjusting: 0x0 Bit Bit 13 (It is Bit 12 up to 100%.)
Refer to the AR-A/AR-B/AR-D series catalog excerpt, which has been reproduced below.
The part number of the standard AR20 to AR60 round type pressure gauge is “G36-10-01,” or “G46-10-01”(for the R thread type).
For example, the part number of the AR30-03BG-A pressure gauge is “G36-10-01.”
Refer to the AR-A/AR-B/AR-D series catalog excerpt, which has been reproduced below.
The part numbers of standard AR20 to AR60 round type pressure gauges are “G36-10-01” and “G46-10-01”(for the R thread type).
For example, the part number of the AR30-03BG-A pressure gauge is “G36-10-01.”
Description Nil None 1 ISO 1179-1 compliant A Bracket A (Interchangeable with ISE70) Output specification1 Symbol Description B Bracket B L2 IO-Link: Switch output 1 + Switch output 2 (Switch output: NPN or PNP switching type) Option 1 1 Refer to pages 7 and 10 for details.
Bit 0 SSC1 Occurs when the output pressure is within 10% F.S. of the target pressure. 8 - Process data output: 4 BYTE (base module --> device (ITV)) This product uses process data to switch between Operation Mode and Standby Mode, and to set Control Stop. Bit No. Byte (Order) No.
Note 10) For thread type: NPT. This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) MPa and psi are shown together on the pressure unit. Round pressure gauge (with color zone): Cannot be used with M. Available by request for special. Note 11) : For thread type: NPT only.
(Nil) ID Case material Material Resin Aluminum Stainless steel Symbol 0 1 2 Port size Connection size Note IDG Symbol C04 C06 C08 C10 C12 02 N02 F02 4 6 8 10 12 IDK SFD100 only Clean One-touch fittings (KP series) Symbol 1 and 2 are made to order. For details, refer to page 325.
.: ZS-50-A) Bracket B (Part No.: ZS-50-B) Thank you for purchasing an SMC ISE70/ISE71/ISE70G/ISE75G/ISE76G/ ISE77G/ISE78G Series High-precision Digital Pressure Switch. Please read this manual carefully before operating the product and make sure you understand its capabilities and limitations. Please keep this manual handy for future reference.
Bracket B (Part No.: ZS-50-B) Unit specification ["Nil" or M]: MPa Display unit Safety Instructions Display colour Output ON: Green/Output OFF: Red (Linked to OUT1) Switch output specifications PNP : Arbitrary display Mode display [F 2] Setting of OUT2 Same setting as [F 1] OUT1. These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Size: 10 (100 â„“/min (ANR), Case Material: 0 (Resin), IN Side Connection Symbol: F02 (G 1/4), OUT Side Connection Symbol: IN/OUT Combination Same Diameter, Option: B (Bracket)
Please prepare the padlock at the customers site. -8- 6Dimensions A B E D Piping Center C E D Piping Center AR-D,ARM-D series AW-D,AWM-D,AWD-D series A B C D E AR20(K)-D,AR20M(K)-D AW20(K)-D,AWM20-D,AWD20-D Applicable Part No.
DIN rail is not suitable for port size F02 (G1/4). No lead wire 1
Body Size: 30, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 02 (1/4), Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Regulator, Pressure Boosting Valve: Regulator, Regulator Type: Standard, Shape: Standard, Operating Environment: Standard, Compatible Fluid: Air, Exhaust Mechanism (Air Bleed): [Included] Relief, Reverse Flow Function (Relief): No, Supply Side Connection Type: G, Supply Side, Connection Diameter: 1/4, Flow Direction: [Right] From Left to Right, Control Side Connection Type: G, Control Side