LX2007. 10 SYM BO L J K L M N o P Q R S T U Year 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 SYM BO L o P Q R S T U V W X y Z M ont h J an Feb M ar Apr M ay J un J ul Aug Sep O ct N ov D ec 4-
outlet 2 x Port size SFD LLB AD GD Ball valve Power source code Port size A 460 588 394 484 33 52 70 70 59 60 485 580 428 505 320 333 150 150 150 150 320 400 70 94 58 65 200 200 480 610 220 220 225 238 Model HAA15 HAA22 B C D E F G H J K L M N P Q R S 1B union union 1 2 B 1 13
Aluminum One-touch Connection and Release High Vacuum Angle Valve Normally Closed/Bellows Seal XLAQ Series How to Order XLAQ M9N 16 A q w e r t y w Indicator/Actuator port direction q Flange size Size 16 25 40 50 Indicator Without indicator Symbol Nil A F G J K L M Rear flange surface Actuator port direction Flange side Flange side Left flange surface Rear flange surface Right flange surface
IR30-OM04-F PRODUCT NAME Precision Regulator MODEL/ Series IR3120 Contents Safety Instructions 2~3 1. Specifications 4~5 2. Construction and operation principle 6 3. How to order 7 4. Marking on product 7 5. Precautions for handling 8~11 6. Warranty 12 7. Troubleshooting 13 8.
ASN AQ ASV AK How to Order VCHC F S 1 0 03 06 3 2 AS ASR ASQ Hexagon lock nut Round lock nut J Nil Lock nut option Speed controller Option None Electroless nickel plated Nil N Body size 1 2 3 4 M5 standard 01, 02 standard 03 standard 04 standard Tube size Note) With seal 04 06 08 10 12 4 6 8 10 12 Made to Order Refer to page 612 for details.
AR425 to 935 Nil A B C D E F G H J K L M N O P Q R ARX AMR ARM ARM With pressure guage With digital pressure switch ARP IR-A Common supply block Common supply block with pressure switch IR L side L side IRV VEX Note 1) Pressure display means a pressure gauge or digital pressure switch is attached.
S None Adapter assembly 4 3 1/4 3/8 1/2 3/4 1 AMR3000/4000 AMR3000/4000 AMR4000/5000 AMR5000/6000 AMR6000 1 standard Port size Thread Thread Symbol Port size Applicable model N F Rc (PT) NPT G (PF) Rc(PT) NPT G(PF) N F 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter ass'y is same as the port size of the body.
F (LC6D-2 only) +24V GND CW+ CW CCW+ CCW PD+ PD A B C D E 7 6 3 10 CW CW 10 10 2 R 330 CCW input 330 CCW input 2 2 9 1 CCW CCW 8 9 9 5 4 14 13 12 R 330 PD input 1 PD 8 11 F Functions Function change-over switch Input signal terminal CW pulse input terminal By applying the pulse input, the actuator moves from the motor side to the end side.
L1 L2 A(2) L3 H(1) T2 T1 D1 D2 Model AS1200-M3 M3 x 0.5 M3 x 0.5 4.5 6.6 23.5 21.5 8 5 5 20.5 18.5 AS1200-M5 M5 x 0.8 M5 x 0.8 25.5 8 10 28.3 10.3 9 9 25 22.2 AS1200-U10/32 10-32 UNF 10-32 UNF AS220-01 27.4 32.4 14.6 14.3 14.1 31.4 36.4 18 12 (12.7) 1/8 1/8 AS220-02 29.8 34.8 19.5 18 18 35.8 40.8 27.2 17 (17.5) 1/4 1/4 AS320-03 35.6 40.6 24.3 22.5 20.8 41.9 46.9 30 19 3/8 3/8 AS420-04 42.4
M Element Replacement Procedure Body Model A B C D E F G H I J K L M N Size Collar part arrow ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 12.8 4 6 8.5 14.4 15.5 50 15 17.5 24 12.5 22.5 53 26 48 Metric size Inch size 15.2 6 8 Transparent cover 9.5 16.6 17.5 61 16 19.5 27 13.5 24.5 65 28 52 57 8 10 18.5 11 18 21.5 65 17 21 29.5 14.5 27 69.5 30 3 16 ZFB101-05 ZFB101-07 ZFB201
F (LC6D-2 only) +24V GND CW+ CW CCW+ CCW PD+ PD A B C D E 7 6 3 10 CW CW 10 10 2 R 330 CCW input 330 CCW input 2 2 9 1 CCW CCW 8 9 9 5 4 14 13 12 R 330 PD input 1 PD 8 11 F Functions Function change-over switch Input signal terminal CW pulse input terminal By applying the pulse input, the actuator moves from the motor side to the end side.
Services 15 Sebaai Street, Miami 21411 Alexandria, Egypt TEL: 3-548-50-34 FAX: 3-548-50-34 PAKISTAN (Distributor) Jubilee Corporation First Floor Mercantile Centre, Newton Road Near Boulton Market P.O.
It may cause malfunction. (3) The product should not be exposed to prolonged sunlight.
Composition and Function of Product. 3-1 3.1 Composition . 3-1 3.1.1 Outline . 3-1 3.1.2 Operating Principles . 3-3 3.2 Function . 3-5 3.2.1 Auto Tuning Function . 3-5 3.2.2 Temperature Upper / Lower Deviation Limit Alarm Function (at shipment). 3-5 3.2.3 Offset Function . 3-7 3.2.4 Set Value MemoryEEPROM back-up . 3-7 3.2.5 Output cutoff Alarm Function . 3-7 3.2.6 Alarm Indication on Operation
(1) (2) IDFA Series 6-2 GWP 6 2 IDX-OM-W017 6 6-3 mm IDFA4E15E1 A B C D E F G H J K L M N P Q IDFA3E Rc3/8 226 410 473 67 125 304 33 73 31 36 154 21 330 231 15 IDFA4E Rc1/2 453 13 498 283 275 IDFA6E 455 275 Rc3/4 15 485 568 355 300 270 31 42 80 230 32 15 240 80 IDFA8E IDFA11E IDFA15E1 Rc1 300 603 578 41 54 396 87 258 43 15 270 101 380 314 16 IDFA Series 6-3 6 3 IDX-OM-W017 6 6-4
F C37 1/2 15 G Stainless steel B 100 VAC Grommet With surge voltage suppressor C 110 VAC 5 20A N.C. H C37 3/4 20 J Stainless steel D 200 VAC E 230 VAC 6 25A N.C.
Note 2) AS900 is available as special. 1/4 3/8 1/2 3/4 1 1 1 2 AS420 Thread type AS500 AS600 AS800 Nil Rc NPT G N F 1 4 1 2 AS900 Needle Valve/Flow Characteristics AS500/600 AS420 AS800/900 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Effective area (mm 2) Effective area (mm 2) Effective area (
Note 2) AS1000, AS2000 are not applicable. 8 3 2 1 Bore size 2 1 Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 AS1000 AS1000 AS2000 AS2000/3000/4000/5000 AS3000/4000/5000 AS4000/5000 Thread type Nil Metric thread (M3, M5) Rc NPT G N F Caution Be sure to read before handling.
Enclosure (IP) F Fieldbus The protocol that uses digital communication to exchange signals between field equipment (instruments and actuators) running on site and a PLC. Full duplex Communication system that can send and receive data at the same time bi-directionally H Half duplex Communication system that sends and receives data in one direction at a time.