A B C D E F A B C D E F G H Pressure port Pressure port Right Left Left Right Left Right Right Left Left Right Right Left Left Right Operating direction Operating direction There are 9 possible reciprocating piping methods. There are 16 possible reciprocating piping methods.

Table displacement due to pitch moment load (marked with the arrow) Table displacement due to yaw moment load (marked with the arrow) Table displacement due to roll moment load (marked with A) F A F F LEPS6 LEPS6 LEPS6 0.30 0.30 0.10 0.25 0.25 Displacement [mm] Displacement [mm] Displacement [mm] 0.08 0.20 0.20 0.06 LEPS6m-50 LEPS6m-50 0.15 0.15 0.04 0.10 0.10 LEPS6m-25 0.02 LEPS6m-25 0.05

O.D.: 4, 5/32" : 6, 1/4" (2.3) L plug connector (L): SYJ5120-L-M5(-F) M plug connector (M): SYJ5120-M-M5(-F) DIN terminal (D): SYJ5120-D-M5(-F) M8 connector (W0): SYJ5120-W0-M5(-F) Approx. 300 (Lead wire length) Applicable cable O.D. 3.5 to 7 82.1 Max. 10 60.9 28.1 [35.1] 53.4 12.7 42.1 32.6 M8 x 1 15.1 39.2 [46.2] Approx. 300 (Lead wire length) Pg7 73 [75.2] (2.3) 63.2 [65.4] 83 72.1 3

(For details, refer to catalog on page 22.) 17 Series SYJ500 Construction c f a e b d c f a e b d N.C. N.O.

AF-OMR0020-C PRODUCT NAME MIST SEPARATOR MODEL / Series / Product Number AFM20-(F,N)01(F,N)02(B,C)(-2,6,C,J,R,Z)-A AFM30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,R,W,Z)-A AFM40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,R,W,Z)-A AFM40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-A Contents Page 1. SAFETY INSTRUCTIONS 1-5 2. APPLICATION 6 3. SPECIFICATIONS 6 4. HOW TO ORDER 7 5. OPTIONAL BRACKET ASSEMBLY 8 6.

Rubber back of the belt is softened and sticky f . Cracks on the back of the belt are visible The traveling parallelism is the reference plane for the body mounting reference plane. If the traveling parallelism for a table is required, set the reference plane against parallel pins, etc.

Press this button to change to the peak display mode. button (UP) [F 4] [F 5] [F 6] [F 7] [F 8] [F 9] [Anr.] Standard condition [1.00] 1 second Selects the mode or decreases the ON/OFF set value. Press this button to change to the bottom display mode. CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.

Piping thread type : When F is selected, G thread adapter set will be added.

Model number: HRS030-F-20 The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.

VCA20-12-1A 41 52 30 40 4.5 6 VCA30-12-1A 48 56 36 44 5.5 7 VCA40-12-1A 50 62 38 50 5.5 7 2 mounting screws (for mounting brackets) are included in bracket part no. 17-2-12 7 Series VCA Direct Operated 2 Port Solenoid Valve For Air Dimensions Grommet: G Conduit: C Q F D Q F 300 280 D VC G1/2 C R C R L VDW IN E E VQ Manual override A B B A 2-P Port size 2-P Port size VX2 VX Manual override

(2.8C) (17 m 3/h) (25 m 3/h) (43 m 3/h) (70 m 3/h) (100 m 3/h) (120 m 3/h) 11 SCFM 16 SCFM 26 SCFM 43 SCFM 62 SCFM 80 SCFM 45 F (7.2C) (19 m 3/h) (27 m 3/h) (45 m 3/h) (74 m 3/h) (106 m 3/h) (136 m 3/h) 17 SCFM 28 SCFM 45 SCFM 65 SCFM 86 SCFM 12 SCFM 50 F (10C) (20 m 3/h) (28 m 3/h) (47 m 3/h) (77 m 3/h) (110 m 3/h) (147 m 3/h) 100psig (0.7MPa) 100 F (37.8C) 100 F (37.8C) 115V 60Hz

AW-OMZ0061 PRODUCT NAME Mist Separator Regulator MODEL / Series / Product Number AWM20-(F,N)01(F,N)02(B,C,E,E1,E2,E3,E4,G,H,M)(-1,2,6,C,J,N,R,Z,ZA)-D AWM30-(F,N)02(F,N)03(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D AWM40-(F,N)02(F,N)04(B,C,D,E,E1,E2,E3,E4,G,H,M)(-1,2,6,8,J,N,R,W,Z,ZA)-D Contents Page 1. Safety Instructions 2-8 2. Application 9 3. Standard Specifications 9 4.

Note 2) For ZSE40 (F)/ISE40-Note 3) For ZSE40 (F)/ISE40-Note 4) For ZSE40F (compound pressure) with "psi" indication, this is 0.03 to 0.04 psi.

Table displacement due to pitch moment load (marked with the arrow) Table displacement due to yaw moment load (marked with the arrow) Table displacement due to roll moment load (marked with A) F A F F L L Distance L [mm] Model LEPS6 LEPS10 Stroke [mm] 25 50 25 50 Distance L [mm] 53.0 77.0 59.5 82.0 LEPS6 LEPS6 LEPS6 0.30 0.30 0.10 0.25 0.25 Displacement [mm] Displacement [mm] Displacement

Piping thread type : When F is selected, G thread adapter set will be added. Piping thread type : When N is selected, NPT thread adapter set will be added.

ECO F RUN MPa ALM PSI WRN LPM GPM Lighting up RUN MPa ALM M RMT WRN LPM H RUN EXT SEC RMT H AT SEC MENU RUN/ MENU RUN/ STOP STOP ENT Press and hold for approximately 1second.

For vacuum/compound pressure : kPa For positive pressure : MPa Setting range Set pressure range Lead wire length 100.0 to 100.0kPa 101.3 to 101.3kPa 100.0 to 100.0kPa Nil 0.6m 3m 10.0 to 101.3kPa 0.1 to 1.000MPa L 1.000 to 1.000MPa 2 High Precision Digital Pressure Switch Dimensions ZSE40(F)/ISE40 01 T1 20 30 M5 x 0.8 thread depth 5 MPa 30 20 OUT2 OUT1 SET Width across flats 2-M3 x 0.5 thread

block mounting position D side U side Kit F Kit F 1 to 18 stations IP65 compatible TD TO Terminal block box 3 to 18 stations Indicator light Manual override L S kit (Lead wire cable) kit (Serial transmission unit) External pilot supply port The valve is equipped with a lamp/surge suppressor, and the voltage is 24 VDC.

G1, Symbol N: NPT1) CH2: Rc1/2 (Symbol F: G1/2, Symbol N: NPT1/2) Tank drain port CH1: Rc3/4 (Symbol F: G3/4, Symbol N: NPT3/4) CH2: Rc1/2 (Symbol F: G1/2, Symbol N: NPT1/2) Fluid contact material (Metal/Resin) CH1: Stainless steel, Copper (Heat exchanger brazing), Brass, Bronze, Fluororesin, PP, PBT, POM, PU, PC, PVC, EPDM, NBR CH2: Stainless steel, Alumina ceramic, Carbon, Fluororesin,

Indicator: Dimensions (b) E C D E C XLA F A (a) XL XL XLQ E (c) XM XY H DXSA XVD B G XGT CYV A (mm) A B C D E Note 1) F G H Model XLH-16 XLH-25 XLH-40 XLH-50 40 100.5 38 1 30 17 35 50 114 48 1 12 40 26 41 65 162.5 66 2 11 55 41 57 70 179.5 79 2 11 75 52 70 Note 1) Dimension E applies when heater option is included.