Note 2) Refer to page 15 for lead wire length. Auto Switch Internal Circuits Auto Switch Weights Unit: g D-F9N, F9NV D-F9N(V) D-F9P(V) D-F9B(V) Auto switch part no.

Soft nylon Polyurethane KAT23-M5 15 9.6 16 15.5 M5 0.8 M6 1.0 8 8 8 15.5 19.5 21 3.4 2.9 9 3.2 1 8 KAT23-M6 KAT23-U01 10 17.5 10 KAT04-M5 15.5 M5 0.8 M6 1.0 17 8 4.3 4.3 6 8 KAT04-M6 16 10.4 16 18 4 1 8 KAT04-U01 20 6.0 6.0 9 14 10 21.5 10 1 4 KAT04-U02 22 15 KAT06-M5 16 M5 0.8 M6 1.0 18 8 8 8 4.3 4.3 KAT06-M6 16.5 17 1 8 KAT06-U01 3 8 KAT06-U03 24 23 21.5 20 11 14 12.8 10 6 23.5 1 4 KAT06

g piece of fluororesin tubing is cut off, washed in DI water (puer water) and immersed in 15 mL of 25% methyl alcohol extract at room temperature for 24 hours.

Rc 3/8 226 410 473 67 125 304 33 36 154 21 330 13 Rc 1/2 453 498 283 275 455 270 31 42 80 240 80 15 15 Rc 3/4 485 568 355 300 300 314 41 54 87 43 101 16 603 578 396 380 Rc 1 Meaning the foot dimensions for the IDFA3E. 94 A Refrigerant R407C (HFC) IDFAE Series 22E, 37E, 55E, 75E (Inlet air temperature: 35C) HAA HAW How to Order AT IDF IDU IDFA 55E 23 Nil C G K L R T V IDF FS Note 1) Size

Delivery pressure Code 1 to 30 psig (0.007 to 0.2 MPa) 2 to 60 psig (0.014 to 0.4 MPa) 2 to 100 psig (0.014 to 0.7 MPa) 5 to 150 psig (0.034 to 1.0 MPa) 02 06 10 15 Bonnet Standard Panel Installation 3) Bonnet port (NPT 1/8 inch) Code No code P BP Material 3) Panel mounting hole: dia.39.6 mm.

No.TQ0010298-OM003-A PRODUCT NAME Digital pressure switch for energy-saving control ejector MODEL / Series / Product Number ZME-ZSE***-A Table of Contents Safety Instructions 2 Model indication and How to order 9 Summary of Product parts 10 Definition and terminology 11 Mounting and Installation 14 Installation 14 Wiring 15 Wiring 15 Internal circuit and wiring example 16 Easy Setting 17

V F.S.=5[V]1[V]4[V] 1F.S.4[V]10.04[V] 15 V 15 V 420 mA ON OFF () (0100)() 90 () (0100) ()90ON(OFF) () 10 L/min 10 L ON OFF ON OFF 0 -14No.PF-OMO0004CN-E , , 2 5 10 L/min 5 ,51050 L ON-OFF () 1 L/min ,10 11 12 1 L/min SI SI ON-OFF ON 0 ripple -15No.PF-OMO0004CN-E AB.

If the installation is using accurate control, wait until the product has warmed up (approximately 10 to 15 minutes) before operation.

JXC-OMT0028CN (GW)(EtherNet/IP) / LEC-GEN1 . 4 2. . 6 2.1 . 6 2.2 . 6 2.3 . 7 2.4 () . 8 (1) . 8 (2)GW . 8 (3)LEC . 8 (4)GW . 8 (5)GW . 8 (6) . 9 (7) . 9 3 . 10 3.1 . 10 3.2 . 12 3.3 . 13 (1)(LECGEN1) . 13 (2)DIN (LECGEN1D) . 13 3.4 . 14 (1) . 14 (2) . 14 4. . 15 4.1GW (B RATE) . 15 4.2 (CN2SW) . 16 4.3LEC . 16 4.4GW EtherNet/IP . 22 5. . 26 5.1 CN4 . 26 5.2 CN3 . 26 5.3

Workpiece mass: 0.05 kg Pressure 0.6 MPa 30 0.5 25 0.4 Gripping force (N) 20 0.3 15 13 0.2 10 0.1 5 0 20 30 50 60 40 70 Gripping point L (mm) When MHY2-16D is selected, the gripping force is determined to be 13 N according to the gripping point distance (L = 35 mm) and the pressure (0.4 MPa).

Applicable bore Shock absorber model ML1-A25H ML1-A32H ML1-A40H ML1C25 ML1C32 ML1C40 101 90 25 20 11 72 67.3 12 31 39.5 Max. 16.5 4.5 3 RB1412 120 107 30 25 16 93 73.2 15 38 49 Max. 20 5.5 6 RB2015 147 129 30 31 16 105.5 73.2 15 40.5 54.5 Max. 25 5.5 6 Side Support Side support A 2 x G E E F 2 x H A B Side support B 2 x J A B (mm) A B C D E F G H J Part no.

Soft nylon Polyurethane KAY23-M5 15 9.6 28.5 15.5 M5 X 0.8 M6 X 1.0 8 8 8 15.5 19.5 33 3.4 2.9 9 3.2 17.5 1 8 KAY23-M6 KAY23-U01 10 10 KAY04-M6 16 18 18.5 15.5 KAY04-M5 M5 X 0.8 M6 X 1.0 8 29.5 6 4.6 4.6 8 10.4 16 4 1 8 1 4 KAY04-U02 22 34 34.5 15 20 KAY04-U01 6.4 6.4 9 14 10 10 18 KAY06-M6 16.5 20 20.5 16 KAY06-M5 M5 X 0.8 M6 X 1.0 32 4.6 4.6 8 8 8 17 1 8 3 8 KAY06-U03 24 23 21.5 37 37.5

A 1.18 (30) 1.61 (41) B 1.34 (34) 1.57 (40) C D E F G 136314 2.76 (70) 2.97 (75.5) .21 (5.4) .26 (6.5) .61 (15.4) .31 (8) 2.17 (55) 2.09 (53) .09 (2.3) .09 (2.3) NARM2500 43.5 136414 NARM3000 30 15 Precautions 0 35.3 70.6 106 Be sure to read before handling.

NO.ZL3-OM00701-A PRODUCT NAME Digital pressure switch for energy-saving control ejector MODEL / Series / Product Number ZSE10ZL3ZL6 series Table of Contents Safety Instructions 2 How to order read wires 9 Summary of Product parts 10 Definition and terminology 11 Wiring 15 Wiring 15 Internal circuit and wiring example 16 Easy Setting 17 Measurement mode 17 Function Setting 20 Function selection

No.TQ0010298-OM003-B PRODUCT NAME Digital pressure switch for energy-saving control ejector MODEL / Series / Product Number ZME-ZSE***-A Table of Contents Safety Instructions 2 Model indication and How to order 9 Summary of Product parts 10 Definition and terminology 11 Mounting and Installation 14 Installation 14 Wiring 15 Wiring 15 Internal circuit and wiring example 16 Easy Setting 17

Gsftrc ArrC'r-rrrns6'r CP seies Cylinder Positioner Assembly Bore Sizes: s50mm, o63mm, s80mm, g100mm lnfinite Control tromZero to FullStroke 3-15 psig Signal Pressure Built-in Feed Back Non-lubed Operation is Standard SERIES CP CYLINDER POSITIONING ASSEMBLY SPECIFICATIONS SPECIFICATIONS CHARACIER|tiNCS Supply Prsgsure 40-100 PSlc (3.0-7.0 KsTcmr) Signal Presure 3-15 PSlc (0.2-l Kq/cm,)

0 y Male connector Male elbow 15 Series KQB2 Applicable Tube: Metric Size, Connection Thread: G Dimensions Male Connector: KQB2H Note 2) Effective area (mm2) Applicable tube O.D.

Note) N, W and V refer to the hydraulic fluid symbol indicated at the end of the element part number. 0 1 With relief valve None Port size Symbol Flange SSA 15 (1/2B) 20 (3/4B) 25 (1B) 32 (1 1/4B) 40 (1 1/2B) 50 (2B) 65 (2 1/2B) 80 (3B) Threaded Rc 3/8 1/2 3/4 1 1 1/4 1 1/2 03 04 06 08 10 12 16 20 24 Replacement Element Part No.

(Refer to page 41 for details.) -40No.PS-OMW0014-B Auto-preset When auto-preset is selected in function selection mode, the set value can be calculated and memorized from the measured pressure.

Do not mount the product in locations where it is exposed to radiant heat. 15 - Maintenance Warning Removal of equipment, and supply/exhaust of compressed air.