SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ7-41-12-01"

Supply should be "1", the outputs 2'and "4', the pilot port connecting"l" with 2" is then "12" etc. Table 7.2 shows the tour main sets of port identifications in use. Preterred are now the numbers.

IC 5 V, 12 V Terminal conduit 12 V Relay, PLC 24 V 3-wire (NPN) 3-wire (PNP) IC 5 V, 12 V Diagnostic indication (2-color) 12 V 2-wire Grommet Water resistant (2-color) 3-wire (NPN) With diagnostic output (2-color) Latch with diagnostic output (2-color) IC 5 V, 12 V H7LF 4-wire (NPN) : Manufactured upon receipt of order.

Figure 12-1 MPC LED Locations Balloon Number Name Description 1 PWR Power OK indicator 2 NS Network Status 3 MS Module Status 4 Link/ACT Bus In Ethernet Link and Activity Status 5 Link/ACT Bus Out Ethernet Link and Activity Status Table 12-2 MPC LED Indentifcation 21 - IN20267 LED LED Status Description Green ON Voltage for the MPC is supplied.

Flow range: 0.5 to 4 L/min (symbol 04) Pressure: 0.3 MPa Piping bore size: 12 Flow range: 2 to 16 L/min (symbol 20) Pressure: 0.3 MPa Piping bore size: 12 Flow range: 5 to 40 L/min (symbol 40) Pressure: 0.3 MPa Piping bore size: 16 -60No.PF-OMW0004-B Analogue output Analogue output (Flow) (PF3W704/720/740) A B C Voltage output 1 V 1.5 V 5 V Current output 4 mA 6 mA 20 mA Rated flow [L/min

Contact protection box OUT(+) Brown [Red] Lead wire length: 0.5m 7 7 6 7 8 8 Resistor Reed switch Lead wire length: 3m 35 35 30 35 41 41 Zener diode CD-P11 OUT() Blue [Black] Contact Protection Box CD-P12 Blue [Black] D-A96(V) Contact protection box internal circuits Type D-A9 switches do not have built-in contact protection circuits.

Ground effect is not adequate by soldering the shield wire with wire rod to install the cable (Fig.2-3). 12.European Contact List (44) 1908-56 38 88 Hungary (36) 1-371 1343 Turkey (90) 212 221 15 12 Finland (358) 9-859 580 Portugal (351) 22 610 89 22 No.LC-OM08901 A (3/3) Denmark (45) 70 25 29 00 Poland (48) 22-548 50 85 Greece (30) 1-342 60 76 Switzerland (41) 52-396 31 31 France (33) 1-

Supply should be "1", the outputs 2'and "4', the pilot port connecting"l" with 2" is then "12" etc. Table 7.2 shows the tour main sets of port identifications in use. Preterred are now the numbers.

52 71 XLFV-63-2 88 212 100 87 95 70 80.5 XLFV-80-2 90 257 117 114 110 83 90.5 Model K L M N S T XLFV-16-2 17.2 10.2 3.6 3.6 M5 M5 XLFV-25-2 21.4 10.2 3.6 3.6 M5 M5 XLFV-40-2 33.9 10.2 3.6 3.6 M5 M5 XLFV-50-2 35.3 12 4 2 Rc1/8 M5 XLFV-63-2 43.8 12 4 2 Rc1/8 M5 XLFV-80-2 59.8 12 4 2 Rc1/8 M5 11 XL-OMV0019 6.

SOmA Nil Relay, Sequence controller D-660 l00VAC Max.2SmA 200VAC Max. 12.SmA Model Load voltage Max. current or conduit range Indicator light Application D-A31 1 00VAC 2SmA Relay, Sequence controller 200VAC 12.SmA D-A37 24VOC S-30mA D-A39 24VDC 10-60mA Sequence controller DIN connector type D-A4 type Relay, Sequence controller Model Load voltage Max. current or conduit range Indicator

Part number of auto switchD-A9D-A9V Unitmm B A (When detecting retracted stroke end) H H 1 H 2 3 (When detecting extended stroke end) 5st 10st 15st 20st 25st 30st 35st 40st 4 6 1 6 11 16 21 26 13.0 10.0 20.0 10 1 6 11 16 21 26 31 36 41 16.0 9.5 19.0 16 1 6 11 16 21 26 31 36 41 18.0 12.0 24.0 Part number of auto switchD-M9D-M9VD-M9WD-M9WV Unitmm B A (When detecting retracted stroke end) H

Dimensions Unit: mm Model A B C D E Fn Fd G H J K XLD-25 50 123 48 1 12 40 26 41 16 7.5 XLD-40 65 170 66 2 11 55 41 63 20 15 XLD-50 70 183 79 2 11 75 52 68 20 17.5 XLD-63 88 217 100 3 11 87 95 70 72 20 20 XLD-80 90 256 117 3 11 114 110 83 98 20 26.5 XLD-100 108 321 154 3 11 134 130 102 133 20 38 XLD-160 138 335 200 3 11 190 180 153 114 30 40 11 XL*-OMI0011-E 7.

CEU5mm-m Multi-counter For details, refer to page 12. 1 LATH3-m Counter cable For details, refer to page 11. 2 Controller setup kit For details, refer to page 12.

, (1015 ) <> 5 UnLLoC 5 5 (30 ) 5 000 (30 ) 41 / 1 -42No.PS-OMM0002CN-F ZSE80(F)/ISE80(H) ,, (), No.1 ON ON OFF Yes No.2 No ON OFF No.1 OFF No.3 No.4 No.5 No.6 No.7 -43No.PS-OMM0002CN-F No.8 Yes No No.9 No.9 No.10 No.11 No.12 No.13 No.14 No.15 No.16 No.17 -44No.PS-OMM0002CN-F No.

RWr(n+20) RWw(n+20) RWr(n+21) RWw(n+21) IO-Link IO-Link : : Process data Process data Port 1 Port 1 RWr(n+2E) RWw(n+2E) RWr(n+2F) RWw(n+2F) RWr(n+30) RWw(n+30) RWr(n+31) RWw(n+31) IO-Link IO-Link : : Process data Process data Port 2 Port 2 RWr(n+3E) RWw(n+3E) RWr(n+3F) RWw(n+3F) Unit No.1 EX600-GILB RWr(n+40) RWw(n+40) RWr(n+41) RWw(n+41) IO-Link IO-Link : : Process data Process data Port

REBR25 REBR32 REBR15 500 400 300 200 300 200 Allowable driving force Fn (N) Load weight W (kg) Allowable driving force Fn (N) Allowable driving force Fn (N) 50 100 100 40 30 40 50 20 30 40 50 30 20 20 Usable range 10 10 10 Usable range Usable range 5 5 5 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 7 8 9 10 11 12

Symbol N 1/2 inch Symbol Nil 12 mm Weight [lbs (kg)] 108 (49) 150 (68) 209 (95) 243 (110) Symbol Accessories Drain tube (Length: 3.5 m) (O.D.: 1/2 inch [Thread symbol: N], 12 mm [Thread symbol: Nil]) Drain tube holder, Operation manual Compliant standards UL, CSA Refrigerated air dryer Auto drain 1 The operating range does not guarantee use with normal air flow capacity. 2 Air flow capacity

19 12 1.8 E2 Dimensions Per Vacuum Inlet: One-touch Fitting Model G H J Fitting part min. hole size Fitting part no.

Body ported, base mounted manifolds old style See replacement series SS5YJ7 New Style , Manifold style: single base/B mount , Valve stations: 2 to 20 , One-touch fittings available, D/R MFLD, 4 STA, N.P.I. *LQA, VALVE, VV4Z/VV5Z MANIFOLD VZ 4/5 PORT, WJ, VV4/5Z* BUILT IN FITTING >1/4, 1.12680 lb

Body ported, base mounted manifolds old style See replacement series SS5YJ7 New Style , Manifold style: single base/B mount , Thread type: North American , Valve stations: 2 to 20 , One-touch fittings available, MANIFOLD, NVZ 5-STA *LQA, VALVE, VV4Z/VV5Z MANIFOLD VZ 4/5 PORT, 1J, VV4/5Z* OTHER SIZE RATING, 1.57080 lb