SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-41-18-M5"

PA07 . 17 4.6 Auto tuning modePr.PA08 . 18 4.7 Input signal automatic on selectionPD01 . 18 4.8 Parameter setting by MR Configurator2TM . 19 4.8.1 Parameter reading . 20 4.8.2 Parameter setting (Ex. Control mode change) . 20 5.

setting 41 Other Settings 42 B How to stop energy-saving control function 45 Maintenance 46 Troubleshooting 47 Error indication 54 Specification 55 -1NO.ZK2-OM00501-B Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Air leaks. -18- 11. Dimensions 11-1. PRESSURE SWITCHIS10M-20-D to IS10M-60-D Model IS10M-20-D IS10M-30-D IS10M-40-D IS10M-50-D IS10M-60-D A B C D 28 77.6 60.1 42 31 85.6 64.1 53 39 93.6 68.1 71 47 96.6 69.6 71 62 106.6 74.6 90 11-2.

No.PS-OMV0008CN-E / / ISE70G--L2 ISE75G--L2 ISE76G--L2 ISE77G--L2 ISE78G--L2 2 9 10 12 15 15 17 19 21 22 3 23 25 27 27 28 F0 30 F1 OUT1 32 F2 OUT2 35 F3 37 F4 38 F6 40 F10 41 F11 47 F14 Zero-cut 48 F80 49 F81 50 F90 52 F96 54 F98 55 F99 57 58 IO-Link 63 IO-Link 63 63 64 IO-Link 67 76 76 77 86 88 -1No.PS-OMV0008CN-E (ISO/IEC)(JIS) *1) *2) *1) ISO

To obtain the Cv factor we have to divide this number by 18: 34 /18 = 1,89. A Tub size of 12 x 9 mm. with "One Touch Fittings' is required to get this speed. Example 2 A 50 mm Dia cylinder has to run with a speed of 400 mm/s, with an available supply pressure ol 7 bar and an allowable pressure drop of 2.5 bar.

N4-18 NCQ2, Series NCQT 200 PSI (14 kgf/cm') -20-150.F (-25 -65"C) 2 20 inch/sec (50-500mm/sec) FEATURES 1) The NCQT Series cylinder gives a shorter, lighter and more compact package for a given stroke. 2) The unique shape enables the use of rail-mounted switches without significantly increasing the overall length. .

(Ball bushing bearing) (mm) AA A E DB Bore size (mm) Bore size (mm) AA E BD 75st, 100st Larger than 100st 37 57 63.5 64 75st, 100st Larger than 100st 50st 25st 50st 25st 50st 75st, 100st 25.50st Larger than 50st 25.50st Larger than 50st 25st Larger than 100st 114 134 160 180 25.50st Larger than 50st 147 168 188 93 63 80 100 63 80 100 41 45.5 46 118 142 162 106.5 115 137 172 198 233 20 25

T) View Z (mm) Dimensions A B C D M N T U V Model LVQ20-S-2 LVQ30-S-2 LVQ40-S-2 LVQ50-S-2 LVQ60-S-2 25.5 46 31.5 58 7 15 35.3 10.6 7 23.5 47 29.5 59 7 15 36.9 16.5 10 23.5 47 29.5 59 7 20 37.9 22 35 70 41 82 7 20 64 25 17 35 70 41 82 7 20 66 32 17-5-69 8 Series LVQ Dimensions With flow rate adjustment & by-pass High back pressure spec. with flow rate adjustment & by-pass N.C. valve M N

If a bend (R) is used, limit it to R3 or less. 916 2-Color Display Digital Flow Switch Series PFM7 Dimensions With bracket / Without flow adjustment valve With bracket / With flow adjustment valve 76 48 36 24 28 4 x 3.4 28 34 26 18 34 26 18 4 x 3.4 36 51.5 (Max. 58.5) 43 1.2 43 48 48 18 18 1.2 Lead wire with connector ZS-33-D DIN rail mounting 18 x n pcs. + 34.4 Brown 18 White Black Terminal

No.JXC-OMT0005CN-A DeviceNet (DC24V) // JXCD1 1. . 4 2 . 6 2.1. . 6 2.2. . 7 2.3 . 8 2.4 () . 9 1 . 9 2 . 9 3 . 9 4PLC . 9 5 . 9 6 . 10 7 . 10 8() . 11 9 . 11 3 . 12 3.1. . 12 3.2 . 13 3.3. . 14 3.4. . 16 (1) . 16 (2) . 16 (3) . 17 4 . 18 4.1 Node Address/Data Rate . 18 4.2 . 19 4.3 DeviceNet . 19 1Step Data Class 67h . 19 2IO Class 68h . 20 3IO . 21 4IO . 21 5 . 23 5.1 PWR

Locked condition (when air is evacuated) Unlocked condition (when air is supplied) 3 Cylinder with Lock Double Acting: Single Rod Series CLS Construction Description Material Note Parts list Description Material Note Parts list No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 No. 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55

Initial Setting method 18 4.1 GSDML file and icons 18 4.2 GSDML file installation 18 4.3 Addition of JXCPH controller to PROFINET network 19 4.4 Registration of the device name of the JXCPH controller to be connected 20 4.5 Assign Device Name 20 5.

Parts and description . 18 2.3. Safe power supply (output). 19 2.4. Block diagram . 19 3. Installation . 20 3.1. Mounting . 20 3.2. Wiring . 21 4. Commissioning . 24 4.1. Configuration . 24 4.2. Diagnostics parameter . 24 4.3. Safe valve power module . 25 4.4. PROFIsafe parameter . 25 4.5.

and terminology 12 Mounting and Installation 14 Installation 14 Piping 16 Wiring 17 Outline of Settings [Measurement mode] 21 Flow Setting (set value only) of OUT1 OUT2 [3 step setting mode] 22 Default settings 22 Function Setting [Function selection mode] 24 Default settings 25 F0 Reference condition/Unit selection function 26 F1 Setting of OUT1 28 F2 Setting of OUT2 36 F3 Response time 41

No.PF-OMP0001CN-F // PFMB7501 PFMB7102 PFMB7202 2 10 11 12 14 14 16 17 [] 21 OU1OUT2 {3 ] 22 22 [] 24 25 F0 26 F1 OUT1 28 F2 OUT2 36 F3 41 F10 42 F13 43 F20 44 F22 45 F30 46 F31 47 F80 OFF 48 F81 49 F90 50 F98 52 F99 53 54 58 59 61 62 62 65 67 -1No.PF-OMP0001CN-F (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems

9 Rod seal NBR Basic (B) CM2QB Bore size Stroke (mm) Stroke range 1 to 300 1 to 300 1 to 300 1 to 300 S 65 65 67 91 N 15 15 15 21.5 Bore A 18 22 22 24 B2 26 32 32 41 D 8 10 12 14 H2 8 8 8 10 I 28 33.5 37.5 46.5 ZZ 119 123 125 157 NA 24 30 34.5 42.5 AL 15.5 19.5 19.5 21 E F 13 13 13 16 K 5 5.5 5.5 7 NN M20 X 1.5 M26 X 1.5 M26 X 1.5 M32 X 2 B1 13 17 17 22 G 8 8 8 11 MM M8 X 1.25 P 1/8 1/8 1

Correction Factors Data Inlet Air Temperature Data Outlet Air Pressure Dew Point Data Air Flow Capacity A C E Inlet air temperature F (C) Correction factor Outlet air pressure dew point F (C) Correction factor 3.5 (100) 7.1 (200) 10.6 (300) 14.1 (400) 17.6 (500) 21.2 (600) 24.7 (700) 28.3 (800) Air flow capacity scfm (L/min [ANR]) Model IDH4 IDH6 68 (20) 1.36 37.4 (3) 0.50 77 (25) 1.24 41

ALARM is expressed as negative-logic circuit. 10 Series LATC4 Options [Actuator cable] Actuator cable LATH1 1 Controller Actuator Actuator side Controller side Cable length (L) 1 3 5 L (25.5) (25.5) 1 m 3 m 5 m (18) (21) (5.2) Raised area (7) (9) Note ) The actuator cable is direction dependent. Make sure to connect the Card Motor side of the cable to the Card Motor and vice versa.

LVC Refer to pages 17-3-40 and 17-3-41 for specifications and models.