369 Series AW10 to AW60 Series AW20K to AW60K Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa AW10 Rc 3/8 AW30(K) AW40(K)-06 Rc 3/4 M5 0.6 0.6 0.6 0.5 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 1000 Flow rate (l/min (ANR)) 0 3000 4000 1000 2000 0 150 125 100 75 50 25 0 0 0 500 1500
(mm) Model Threaded Note) Flange Av x 10-6 m2 VNC1-6A VNC1-8A VNC1-10A VNC24-10A VNC2-10A VNC24-15A VNC2-15A VNC34-20A VNC3-20A VNC44-25A VNC4-25A VNC54-32A VNC5-32A VNC54-32F VNC5-32F VNC64-40A VNC6-40A VNC64-40F VNC6-40F VNC74-50A VNC7-50A VNC74-50F VNC7-50F 1 8 1 4 30 32 36 95 120 110 140 170 260 220 370 400 560 400 560 630 820 720 960 990 1500 1000 1600 0.3 0.2 7 3 8 11 15 11 15 14
Flow-rate Characteristics Note) Values when the main valve is fully open Male thread nozzle High efficiency nozzle 1L = 0.035 SCFM 1L = 0.035 SCFM 14.5 29.0 43.5 58.0 72.5 87.0 102 116 131 145 psi 14.5 29.0 43.5 58.0 72.5 87.0 102 116 131 145 psi 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 400 VMG1-R02-400:4 KNH-R02-200 VMG1-R02-350:3.5 350 VMG1-R02-300:3 Flow rate [
Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.
Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.
Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.
Auto Switches Common Specifications Type Reed auto switch Solid state auto switch 1 ms or less 1.2 ms Operating time 300 m/s2 1000 m/s2 Impact resistance 50 M or more at 500 VDC Mega (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Withstand voltage 10 to 60C Ambient temperature IEC60529
SP Nil 6 10 15 20 25 30 300 mm 600 mm ZCUK 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm AMJ AMV How to Order AEP ZM Nozzle diameter Body style Standard supply pressure HEP
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Maximum operating pressure 0.97 MPa Minimum operating pressure 0.05 MPa Piston speed 50 to 500 mm/s Cushion Air cushion 0 to 70C (No freezing) Without auto switch Ambient and fluid temperature JIS Symbol Double acting 0 to 60C (No freezing) With auto switch Lubrication Not required (Non-lube) Stroke Tolerance +1.0 0 250 or less +1.4 0 251 to 1000 Stroke length tolerance (mm) +1.8 0 1001 to 1500
4 Short head cap screw t Top cover Top cover kits 4 Series CKZ2N Maximum Cylinder Locking Moment Bore size (mm) Max. locking force Nm Ibfin 50 63 80 800 1500 2500 7080 13274 22124 Maximum Clamping Moment Max. clamping force Bore size (mm) Nm 0.3 MPa Ibfin Nm 0.4 MPa Ibfin Nm 0.5 MPa Ibfin Nm 0.6 MPa Ibfin Nm 0.7 MPa Ibfin Nm 0.8 MPa Ibfin 50 63 80 100 300 560 885 2655 4956 130 350 720 1150
Lead wire length Nil 300 mm 6 600 mm 10 15 20 25 30 50 1000 mm Ground nut 1500 mm Set screw Tightening torque 2000 mm Tightening torque 0.37 to 0.44 lbfft 1.84 to 2.77 lbfft (2.5 to 3.75 Nm) 2500 mm (0.5 to 0.6 Nm) 3000 mm Housing Washer 5000 mm How to Order Specify the connector assembly part number together with the part number for the plug connector type solenoid valve without connector
Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.
detailes, refer to Best Pneumatics catalog. 54 Series NCM Auto Switch Specifications Auto Switch Common Specifications Solid state switch Reed switch Type Leakage current 3-wire: 100 A or less 2-wire: 0.8 mA or less None Operating time 1 ms or less 1.2 ms 300 m/s2 1000 m/s2 Impact resistance 50 M or more at 500 VDC Mega (between lead wire and case) Insulation resistance Withstand voltage 1500
Auto Switches Common Specifications Type Leakage current 3-wire: 100 None Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 Insulation resistance 50 M or more at 500 VDC Mega (Between lead wire and case) 1500 VAC for 1 minute (1) Withstand voltage (Between lead wire and case) (Between lead wire and case) Ambient temperature 10 to 60C Enclosure IEC60529 Standard
Pink Brown Blue Blue Red Red Black L 20 1-13 2M2.6x0.45 53.5 15.2 25 L 41 41 53 D-sub connector cable ass'y Electric characteristics Item Characteristics Conductor resistance /km, 20C Cable length (L) Ass'y No. 57 or less GVVZS3000-21A-1 GVVZS3000-21A-2 GVVZS3000-21A-3 GVVZS3000-21A-4 GVVZS3000-21A-5S Connector made in conformity with DIN47100. 1m 3m 5m 8m 20m Voltage limit V, 5min, AC 1500
Parallel I/O Type: P (PNP), I/O Cable Length: 5 (5), Option: Screw Mounting, Type: C (Cam Follower Guide Type), Size: 32, Motor Mounting Position: L (Symmetric, Top Mounting), Stroke: 1500
Parallel I/O Type: P (PNP), I/O Cable Length: 1 (1.5m), Option: Screw Mounting, Type: C (Cam Follower Guide Type), Size: 32, Motor Mounting Position: U (Bottom Mounting), Stroke: 1500