Stations Ports 1, 3, 5 position Symbol 02 Stations 2 stations Note U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 20 stations) Note 1) Double wiring specifications 16 02 16 stations 2 stations Supply/Exhaust block assembly specification Note 2) Specified layout (Up to 32 solenoids possible.) 20 20 stations Nil S R RS Internal pilot specification Internal pilot
Z 12 or less 15 or less 2 position single 10 or less 10 or less 13 or less 2 position double 15 or less 16 or less 20 or less 3 position Type R, U Type S, Z 33 or less 38 or less 2 position single 27 or less 28 or less 30 or less 2 position double 50 or less 50 or less 56 or less 3 position SY9000 SY5000 With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa)
RS Q G RS H A RZQ Accessory Dimensions MI W S Rod end nut (mm) CEP1 d: Thread nominal size M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1 M8 x 1.25 M10 x 1 M10 x 1.25 M10 x 1.5 M12 x 1.25 M12 x 1.5 M12 x 1.75 M14 x 1.5 M16 x 1.5 M16 x 2 M18 x 1.5 d: Thread nominal size M20 x 1.5 M20 x 2.5 M22 x 1.5 M24 x 1.5 M24 x 2 M24 x 3 M26 x 1.5 M27 x 1.5 M27 x 2 M30 x 1.5 M30 x 2 M33 x 2 M36 x 1.5 M39 x
2 4 4 4 4 14 16 18 18 22 22 16 20 20 22 24 28 32 41 41 46 55 70 1.25 2 2 2.5 3 3 9000 14000 22000 36000 55000 55000 20Data Option: Heavy Load Type Hydraulic: Up to 7 MPa JAHL63-24-200 JAHL80-30-200 JAHL100-42-300 63 80 100 24 30 42 155 187 213 88 96 116 56 67.5 78 4.1 6.4 10 2 2 3 38 45 55 66 79 96 54 60 74 36 44 48 102 125 144 70 80 90 69 79 89 4 4 4 18 18 22 20 22 24 41 46 55 24 38 42 2
CC Graph 2 Note) Be sure to use a flat washer to mount cylinders via through holes. 3 MK2l50/63 2 MK2l32/40 102 When arm's moment of inertia is 5 X 103kg/m2, cylinder speed should be less than MK2l32/40: 66mm/s MK2l50/63: 120mm/s Refer to p.4.1-21 for calculating moment of inertia.
Port 1 Port 2 B Port 2 PS2410202-20-20 4.67" 3.38" 2.63" 2.88" 1 1/4-11 1/2 1 1/4-11 1/2 118.6 mm 85.9 mm 66.7 mm 73.0 mm NPTF NPTF PS2410202-24-24 4.67" 3.38" 2.63" 2.88" 1 1/2-11 1/2 1 1/2-11 1/2 118.6 mm 85.9 mm 66.7 mm 73.0 mm NPTF NPTF Port 1 PS3210202-32-32 4.88" 3.58" 3.06" 3.35" 2-11 1/2 2-11 1/2 123.9 mm 90.8 mm 77.6 mm 85.1 mm NPTF NPTF Dia Wrench Flats Quick Coupling Division 8145
Direct operation valve Qmax 11.1 Effective area S = (mm 2) Qmax 11.1 Effective area S = (mm 2) Select a valve (solenoid valve) having an effective area that is greater than that of the effective area formula given above from the related equipment (P . 13-14-4).
/2 14-19-31 28 Membrane Air Dryer Unit Type Series IDG Units (Type M, Type V) How to Order 03 IDG 30 M Option Symbol Contents Size 3 5 10 20 30 50 60 75 100 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Size Nil Standard 3 (2) (1) (2) (2) (2) P With fitting
Repeatability 0.1% F .S. or less Output voltage: 1 to 5 V (Within rated pressure range (Differential pressure)), Output impedance: Approx. 1 k ISA2 Voltage output Note 2) Linearity: 0.2% F .S.
type Number of auto switches M Slide bearing Nil 2 S 1 n n Bore size 12 10 mm x 2 16 12 mm x 2 20 16 mm x 2 25 20 mm x 2 32 25 mm x 2 40 32 mm x 2 50 40 mm x 2 63 45 mm x 2 80 56 mm x 2 100 71 mm x 2 Auto switch Nil Without auto switch (Built-in magnet) For applicable auto switches, refer to the table below.
R and S (Because S function is also included in R.) S and T (Because S function is also included in T.) Note 2) Voltage symbol 20 (200 VAC) is the terminal block connection as standard. Option S cannot be chosen. Voltage symbol 10 (100 VAC) is the power cable with plug as standard.
9i @2 q r y#0 $0 $2 w $3 #8 @9 A C B Section A !2 !2 #4 @6 #9 @8 $4 #2 #1 #6 #7 $6 !0 u @5 !6 @1 !1 $7 o $8 e $1 !2 Section B Section C 100 80 63 50 40 32 80, 100 80, 100 Description Material Note Parts list Description Material Note Parts list No. No.
acting) 16 20 Bore size: 16, 20 Q S M L A + 2 stroke B + Stroke H + Stroke V W X E G T 0 0.1 D Width across flats K E Workpiece transfer direction 2 x N through 4 x O counterbore 2 x P (Rc, NPT, M thread) F Stroke Y Q S M L A + 2 stroke B + Stroke H + Stroke V G T 0 0.1 D E M L A + 2 stroke B + Stroke H + Stroke V Width across flats K Workpiece transfer direction 2 x P (Rc, NPT, G) F Z X
Table 1 Moment of inertia Size Allowable kinetic energy (J) 10 0.00015 15 0.00025 20 0.0004 30 0.015 40 0.03 How to calculate the load energy E : Kinetic energy (J) I : Moment of inertia (kg m Speed (rad/s) : Rotation angle (rad) 1803.14 rad t : Rotation time (s) 1 E = I 2 2 2 = t Table 2 Safety operable rotation time adjustment range Size Rotation time ( s / 90) 10 0.03 to 0.5 15
Specification 1.1 LECS series driver 1.1.1 How to order L E S Y H 16 D S2 A 50 S 2 A1 (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (3)Motor type (2)Motor mouting position (1) Size Symbol type Output D In-line 16 25 Size Compatible driver [W] R Right side parallel AC servo motor LECSA-S1 LECSA-S3 S2 100 16 L Left side parallel S3 200 25 (Incremental encoder) LECSB2-T5 LECSC2-T5 LECSS2-T5 T6 100
7 31 - No.ZQ-OM01401-B 9. 9.1 ZQA [] 5 to 50 () 2] 1) 20 [m/s 2] 2) 100 [m/s CE / UKCA (EMC RoHS ) 1) 10~150Hz X,Y,Z 2 () 2) X,Y,Z 3 () ZQ05A ZQ07A ZQ10A [mm] 0.5 0.7 1.0 [MPa] 0.35 0.43 1) -80 [kPa] 1) 5 10 22 [L/min (ANR) ] 1) 15 25 47 [L/min (ANR) ] (P) 0.3 to 0.5 2) 0 to 0.45 3) [MPa] (PD) [MPa] 0.75 8 6 4 65 68 70 4) () 64 66 68 [dB (A)] 1) 2) P 0.05MPa 3) 0.1MPa 4
Note 2) When changing the port location, please order a new port plug: MXH-P (2 pcs.)
A G i 2 x P Port size G A 2 x P Port size b B Conduit DIN terminal D F Q S Cable 6 to 12 G1/2 F Q 280 D G1/2 45 (42) (44) 31.5 Built-in full-wave rectifier type R C C R E J J E 2 x M depth 5 H 2 x M depth 5 B B1 H G A G A B B1 2 x P Port size 2 x P Port size Bracket mounting hole a1 (VXS23, 25) a a1 (VXS24, 26) 6.5 10.5 Dimensions (mm) Model Port size P A B B1 C D E F G H J M Bracket mounting
CS1L125SCS1125, #2 CS1L140SCS1140, #2 CS1L160SCS1160, #2 CS1L180SCS1180, #2 CS1L200SCS1200, #2 CS1L250SCS1250, #2 CS1L300SCS1300, #2 The drawing shows with an auto switch.