Search Results "NCDY2S40H-1500B-A73L"

Magnet: D (Built-in), Bore Size: 32 (1 1/4 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1000 (10 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M, Number: 3 pcs.

Magnet: D (Built-in), Bore Size: 32 (1 1/4 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2000 (20 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M, Number: 3 pcs.

Magnet: D (Built-in), Bore Size: 32 (1 1/4 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2000 (20 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M

Magnet: D (Built-in), Bore Size: 32 (1 1/4 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2500 (25 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M

Magnet: D (Built-in), Bore Size: 32 (1 1/4 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 3000 (30 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M, Number: 3 pcs.

Magnet: D (Built-in), Bore Size: 32 (1 1/4 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 3000 (30 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M

Magnet: D (Built-in), Bore Size: 32 (1 1/4 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 0500 (5 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M

Magnet: D (Built-in), Bore Size: 32 (1 1/4 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 1000 (10 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M

Magnet: D (Built-in), Bore Size: 40 (1 1/2 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 3000 (30 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M, Number: 3 pcs.

Magnet: D (Built-in), Bore Size: 40 (1 1/2 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 4000 (40 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M, Number: 4 pcs.

Magnet: D (Built-in), Bore Size: 32 (1 1/4 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1200 (12 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M, Number: S (1 pc.)

Magnet: D (Built-in), Bore Size: 40 (1 1/2 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 4000 (40 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M, Number: 3 pcs.

Magnet: D (Built-in), Bore Size: 40 (1 1/2 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 4000 (40 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M, Number: S (1 pc.)

Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL RODLESS, SLIDER, AIR HYDRO, ACTUATOR, NCY2S GUIDED CYLINDER, IC, 25MM NCY2S OTHERS (COMBO), .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, LOW SPD, ACTUATOR, NCY2S GUIDED CYLINDER, LC, 32MM NCY2S OTHERS (COMBO), .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, LOW SPD, ACTUATOR, NCY2S GUIDED CYLINDER, GC, 15MM NCY2S OTHERS (COMBO), .00000 lb

Accuracy: H (High Precision Type), Size: 63, Motor Type: V7 (200W Output, Absolute Encoder), Lead Screw: A (LEJS40: 16mm; LEJS63: 20mm), Stroke: 1500mm, Motor Option: B (w/Lock), Actuator Cable Type: R (Robotic Cable, Flexible Cable), Cable Length: C (20m), Driver: U2 (LECYU2-V, 200~230V, Absolute, MECHATROLINK-III), I/O Cable Length: 1 (1.5m)

Accuracy: High Precision Type, Size: 63, Motor Type: 200W Output, Absolute Encoder, Lead Screw: LEJS40: 16mm; LEJS63: 20mm, Stroke: 1500mm, Motor Option: w/Lock, Actuator Cable Type: Robotic Cable, Flexible Cable, Cable Length: 20m, Driver: LECYU2-V, 200~230V, Absolute, MECHATROLINK-III, I/O Cable Length: 1.5m

Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy