Function: 5 (3 Position Pressure Center), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: T (NPTF)
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: T (NPTF)
Body Size: 40, Thread: N (NPT), Port Size: 03 (3/8), Option: CG (C + G), Attachment: T (T-Interface), Semi-Standard 1: 3 (Lubricator w/Drain Cock, Exhaust Port), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: N (NPT), Port Size: 03 (3/8), Option: C (N.C. Float Type Auto Drain), Attachment: T (T-Interface), Semi-Standard 1: 3 (Lubricator w/Drain Cock, Exhaust Port), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: T (T-Interface), Semi-Standard 1: 3 (Lubricator w/Drain Cock, Exhaust Port), Semi-Standard 2: WZ (W + Z)
Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Option: Standard, Attachment: T (T-Interface), Semi-Standard 1: 3 (Lubricator w/Drain Cock, Exhaust Port), Semi-Standard 2: WZ (W + Z)
/Single Unit), Solenoid Valve Option: E (Brass Body, EPDM Seal, Class H), Suffix: Standard, Port Size: 03 (3/8), Thread Type: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Electrical Entry: T (Conduit Terminal), Full-wave Rectifier: None
Solenoid: No.3 Solenoid, Body Size: 9 (50A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.3 Solenoid, Body Size: 8 (40A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 14 [1 1/2 (40A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.3 Solenoid, Body Size: 8 (40A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 14 [1 1/2 (40A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Solenoid: No.3 Solenoid, Body Size: 9 (50A), Style: 2 (Energized Closed/N.O.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Solenoid: No.3 Solenoid, Body Option: 8 (40A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 14 [1 1/2 (40A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Solenoid: No.3 Solenoid, Body Option: 8 (40A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 14 [1 1/2 (40A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.3 Solenoid, Body Option: 8 (40A), Style: 0 (Energized Open/N.C.), Option: D (BC6, Copper Body & Shading Coil, FPM Seal, Class H Coil), Port Size: 14 [1 1/2 (40A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.1 Solenoid, Body Option: 5 (20A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 06 [3/4 (20A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Solenoid: No.3 Solenoid, Body Option: 9 (50A), Style: 0 (Energized Open/N.C.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.3 Solenoid, Body Option: 9 (50A), Style: 0 (Energized Open/N.C.), Option: D (BC6, Copper Body & Shading Coil, FPM Seal, Class H Coil), Port Size: 20 [2 (50A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor)
Model: 32, Orifice: 2 (2.2mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 03 (3/8), Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Electrical Entry: T (with Conduit Terminal), Surge Suppressor: Non, Rectifier: R (AC Class B Coil w/Full-wave Rectifier), Bracket: B (Bracket)
Model: 32, Orifice: 4 (4mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 03 (3/8), Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Electrical Entry: T (with Conduit Terminal), Surge Suppressor: Non, Rectifier: R (AC Class B Coil w/Full-wave Rectifier), Bracket: B (Bracket)