The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids.
The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids.
The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids.
The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids.
The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids.
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None
Pressure Range: ISE70G (0 to 1 MPa), Piping: 02 (Rc 1/4), Orifice: None
Pressure Range: ISE75G (0 to 2 MPa), Piping: 02 (Rc 1/4), Orifice: None
Pressure Range: 0 to 10 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1.6 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: ISE78G (0 to 16 MPa), Piping: 02 (Rc 1/4), Orifice: None
Pressure Range: ISE79S (0 to 50 MPa), Piping: 02 (Rc 1/4), Orifice: None
Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None
PRESSURE SENSOR FOR GENERAL FLUIDS. F39. 95.00000 lb. PRESSURE SWITCH, PSE100-560.
Indicator Switch (Option) Specification Wiring Diagram ISH NPN 3.8 to 30 VDC Max. 0.4 VDC Max. 11 mA Max. 20 mA AWG 24 3 m Blue (BL), Brown (BN), Black (BK) Code Output type Power supply voltage Output voltage Supply current Output current BN + BL Indicator switch Load BK Lead wire Cable length Color (Lead wire) Cable 1082 Diaphragm Valve for Ultra High Purity Manually operated type (For
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link
To use the power of the device, the total load current must be 200 mA or less. 2 Refer to 2.4.2 Contact output signal 4 to 6. 3 For option D With electrical conductivity control, it can be set. 2.2 Communication specification HRS400-A-46 2-2 DOC1003626 Chapter 2 Contact input/output communication / Analog output communication 2.2-3 / PIN No.
To use the power of the device, the total load current must be 200 mA or less. 2 : Refer to 2.4.2 Contact output signal 4 to 6. 2.2 Communication specification HRL Series 2-2 HRX-OM-W069 Chapter 2 Contact input/output communication /Analog output communication Table 2.2-3 Contact input/output communicatin /Analog output pin number PIN No.