Discharge capability 1) Flow-rate characteristics PB1013A Flow-rate characteristics (5Hz) PB1013A flow-rate characteristics (When operated at PB1013A5Hz 5H ) 0.7 Discharge pressure (MPa) 0.6 SUP=0.7MPa 0.5 MPa SUP=0.5MPa 0.4 SUP=0.35MPa 0.3 SUP=0.2MPa 0.2 0.1 0 0 200 400 600 800 1000 Discharge rate (mL/min) mL/min Caution The above flow characteristic graph is for clean water (viscosity
Discharge capability 1) Flow-rate characteristics PB1313A Flow-rate characteristics (5Hz) PB1313A5Hz 0.5 SUP=0.5MPa Discharge pressure (MPa) 0.4 SUP=0.4MPa MPa 0.3 SUP=0.3MPa 0.2 SUP=0.2MPa 0.1 0 0 200 400 600 800 1000 Discharge rate (mL/min) mL/min Caution -The above flow characteristic graph is for clean water (viscosity 1mPas, specific gravity 1.0).
If it has a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors inrush currents of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s Operating time Max. 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% for breaker capacity) Operating characteristics
Current (% to the capacity of the main breaker of this product) Figure 3-6 Breaker operating characteristics curve HRZ Series 3.3 Procedure for Installation 3-9 3-9 HRX-OM-X010 Chapter 3 Transporting and Installation HRZ008-L-F HRZ008-L1-F 4h 2h 1h 30min 20min 14min 10min 6min 4min MAX MAX 2min 1min Operating time 30s 20s 10s MIN 5s 2s MIN 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400
H 5 100 VAC 200/40 400/70 Initial power / Power consumption (W) 200 VAC 800/40 1600/80 Note 1) Initial power and power consumption are nominal values. The heaters are PTC thermistor type design. These 200V thermistors self regulate their temperature by switching the resistance at certain critical 100V temperatures, so a separate temperature controller is Current unnecessary.
(Table 1) Table 1 Example of applicable fitting: Male connector (O-ring parallel thread) (Made by Swegelok) Cylinder Fitting thread size for Example of Piping tube OD (inch) model piping applicable fitting CYV15 5/16-24 UNF SS-200-1-OR 1/8 CYV32 7/16-20 UNF SS-400-1-OR 1/4 2.
Device needs to be rebooted after change 400 16 5 5.5 9.5 (14") 5 9.5 450 18 6 7.5 (16") 500 20 6 4.5 600 24 5.5 650 26 7 700 28 7 750 30 6 800 32 900 36 5.5 1) Seat supported 2) Trunnion 3) Soft seated R-valve 4) Low Cv Finetrol 5.5.12 Language selection, LANG Select between three languages EnG, GEr or FrE using the + and keys. To conclude press the ?
17 18 5-2 19 5-3 20 6. 6-1 1 3 4 7 5 2 6 8 9 10 11 6-2 1 11 10 9 2 3 4 5 6 7 8 12 AC DC LCD 21 7. 7-1 7-1-1 1 ISO VG32 060 1m 7-1-2 M4 DIN [050] [25%85%] [1055Hz 0.75mmXYZ 2 ] 7-2 7-2-1 AC100V15AC85VAC115V 50/60Hz DC24V100.4A 2 0.75mm 2D FG0.75mm 100 FG FG 7-2-2 5m 20m5m20m CE1-H0374 22 CE1-R 20m 200m 5m 20m * A DC12V 0.3A B AWG24 DC12V 0.3A CEU2 CE2 U 25mm 400
35 45 Rc1/16 8.6 15 M8x1.25 14 Rc1/4 40 54 Rc1/8 V 26 7-2 27 7-3 R03-P8F 28 8-1 8-2 AC DC LCD 29 9-1 9-1-1 0.1 ()0.1[MPa] 1 (2) 1 () 2 () 2 () 3 4 (LM ) ()() (1 2 30 14.5mT 14.5mT 15000 18cm 20m 20m 31 9-1-2 M4 DIN [050] [25%85%] 1055Hz0.75mmXYZ 2 9-2 9-2-1 AC100V15AC85VAC115V 50/60Hz DC24V100.4A 0.75mm 2 FG0.75mm 2D 100 FG FG 9-2-2 5m 20m5m CE1-R U 25mm *400
referring to its latest catalogue information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment. 100 0.05 0.09 0.15 0.24 0.39 0.64 1.00 125 0.07 0.11 0.18 0.29 0.47 0.76 1.20 150 0.08 0.13 0.21 0.34 0.54 0.89 1.30 200 0.10 0.17 0.28 0.44 0.70 1.10 1.70 250 0.13 0.21 0.34 0.54 0.86 1.30 2.10 300 0.15 0.25 0.40 0.64 1.00 1.60 2.50 400
. *2 (4) S troke [mm] Standard Produced upon receipt of order 300 200 400 500 600 700 800 900 1000 1200 1500 Str o k e (m m ) Ty pe LEJS40 LEJS63 *2Strok es other than standard and produced up o n receipt o f order are available as special orders, so plea s e contact with our com pany . (9) Driver type *4 (7) Cable type *4 *5 *6 Com patible driv er P owe r supply v oltage [V ] Without cable
. -3- 1Specification High performance Battery-less absolute encoder LESYH*(D,R,L)G* LESYH LESYH LESYH LESYH LESYH LESYH LESYH Model 8*GA 8*GB 8*GC 16*GA 16*GB 25*GA 25*GB Stroke[mm] 50,75 50,100 50,100,150 Max.work load[kg] 2 8 12 Horizontal Vertical 1.5 3 6 6 12 10 20 note1)note3) Pushing Force 18~36 37~74 69~138 70~140 135~270 197~395 382~765 note1)note3) 20~800 10~400 5~200 20800 10400
Applicable communication cable CC-Link Ver.1.10-compatible cable (Three-core twisted-pair cable with shield) Communication speed (bps) 156k 625k 2.5M 5M 10M Cable length Total cable length (m) 1200 900 400 160 100 For a system with a CC-Link Ver.1.00-compatible cable coexisting, the maximum length and station-tostation length of the communication cable should follow the specifications for
system Frame synchronous communication Encoding method NRZI Transmission system Bus system (EIA RS485 compliant) Communication format HDLC compliant Error control system CRC (X16+X12+X5+1) Applicable communication cable CC-Link Ver.1.10-compatible cable (Three-core twisted-pair cable with shield) Communication speed (bps) 156k 625k 2.5M 5M 10M Cable length Total cable length (m) 1200 900 400
Modbus EEPROM LED PWR LED ALM L ERR CC-Link L RUN CC-Link 20m oC40 oC() 0 90%RH ) oC60 oC () -10 90%RH ) 2 4.9m/s IP20 50MDC500V 170g() 190g(DIN ) [CC-Link ] CC-Link Version 1.10 1 2 4 (/) 32 /32 4 /4 64 /64 8 /8 128 /128 16 /16 156k/625k/2.5M/5M/10Mbps NRZI (EIA RS485) HDLC 16+X 12+X 5+1) CRC(X CC-Link Ver.1.10 () (bps) 156k 625k 2.5M 5M 10M (m) 1200 900 400
10Mbps Communication method Broadcast Polling System Synchronization system Frame synchronous communication Encoding method NRZI Transmission system Bus system (EIA RS485 compliant) Communication format HDLC compliant Error control system CRC(X16+X12+X5+1) Applicable communication CC-Link cable cable 156k 625k 2.5M 5M 10M Maximum length of Communication cable speed (bps) Total cable 1200 900 400
) LED LED PWR CN2 STAT CN2(TB/PC ) BUS STAT IF ALM L ERR CC-Link L RUN CC-Link LED 10.LED ALM LED (7) 12.LEC 9 - 3. 3.1 DC24V10% 200mA () 300mA () (LEC ) 12 UL , UL1310 Class2 CC-Link CC-Link Version 2.0 4 8 ( 896 108word / 896 108word) 156k/625k/2.5M/5M/10Mbps NRZI (EIA RS485) HDLC 16+X 12+X 5+1) CRC(X CC-Link (bps) 156k 625k 2.5M 5M 10M (m) 1200 900 400
LECGPR1 1 2 3.4 3LEC LEC 4. 4 LEC 4 LEC 4 5 CN1~CN3 5. 8 - 6 DC24V LEC LEC LEC 12.4 LED LED PWR CN2 STAT CN2TB/PC BUS STAT IF ALM SF BF LED 10.LED ALM LED 7 12.LEC 9 - 3 31 DC24V10% 200mA 300mA LEC 5 57words 57word UL , UL1310 Class2 Profibus Profibus DP V1 DP slave 0125 ID 1414 GSD Dsub 9.6k 19.2k 45.45k 93.75k 187.5k 500k 1500k 12000k (bps) (m) 1200 1000 400
If the breaker with shorter operating time is connected, the customers equipment could be cut off due to the inrush current of the motor of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min MAX 2min 1min 30s 20s Operating time 10s 5s MIN 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 130 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% to the capacity of the main breaker of this
SGC200/300/400: Special request X1(SF4-X240) SGC500/600/700: Installed pilot valve VO307 Caution 7 SGC200-OMM0002-F SGC / SGH Series Coolant Valve / Precautions 5 Be sure to read this before handling.