SMC Corporation of America
Elite Part Number Search
Search Results "CXSJM10-40-M9P"

When operating more than 2 auto switch cylinders in parallel, separate the tubes at least 40 mm or more. 4. Avoid wiring that applies repeated bending stress , and/or tensile force on the lead wire. 5. Consult SMC when the product is subject to continuous splash of water or liquid coolant, etc. 6.

(mm) 50 30 63 30 80 40 1-4. (mm) (Kg) 50 1.70 / 63 2.78 80 4.96 4 - RS1H 1. mA 2. V(m/min) (Kg) 3.

Maintain a minimum cylinder separation of 40 mm. (When the allowable interval is specified for each cylinder series, use the indicated value.) The auto switches may malfunction due to interference from the magnetic fields. Use of a magnetic screen plate (MU-S025) or commercially available magnetic screen tape can reduce the interference of magnetic force. 3.

Maintain a minimum cylinder separation of 40 mm. (When the allowable interval is specified for each cylinder series, use the indicated value.) The auto switches may malfunction due to interference from the magnetic fields. Use of a magnetic screen plate (MU-S025) or commercially available magnetic screen tape can reduce the interference of magnetic force. 3.

Magnet: D (Built-in), Mounting: B (Basic), Cushion: A (Air Cushion), Bore Size: 40 (1 1/2"), Stroke: 0100 (1"), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Bore Size: 15mm, Port Thread: Bore 10, 15: M Thread, Bore 20, 25, 32, 40: Rc, Stroke: 250mm, Switch Rail: Switch Rail, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: B (1pc, Valve Open)

Magnet: D (Built-in), Mounting: B (Basic), Cushion: N (Rubber Bumper), Bore Size: 40 (1 1/2"), Stroke: 2100 (21"), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Mounting: B (Through Hole Both Ends Tapped Common), Bore Size: 40 mm, Cylinder Port: TN (NPT), Stroke: 10 mm, Rotation: L (Left Rotation), Body Option: N (Arm), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Mounting: B (Through Hole Both Ends Tapped Common), Bore Size: 40 mm, Cylinder Port: TN (NPT), Stroke: 10 mm, Rotation: R (Right Rotation), Body Option: N (Arm), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Seal kit includes a grease pack (125 to 160: 40 g, 180, 200: 50 g, 250: 60 g). Order with the following part number when only the grease pack is needed.

Valve Type: XLD (Smooth Exhaust, Normally Closed, Bellows, O-ring Seal), Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: B (1pc, Valve Open)

Valve Type: XLD (Smooth Exhaust, Normally Closed, Bellows, O-ring Seal), Flange Size: 40, Flange Type: KF(NW), Port Direction: L (w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface), Temperature: 5 to 60°C, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed)

Valve Type: XLD (Smooth Exhaust, Normally Closed, Bellows, O-ring Seal), Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: L (3m), Number: A (2pcs, Valve Open/Closed)

Valve Type: XLD (Smooth Exhaust, Normally Closed, Bellows, O-ring Seal), Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed)

Indicator light Lead wire length (m) Load voltage Wiring (Output) Pre-wired connector Applicable load DC AC Auto switch model Electrical entry Type Special function Perpendicular In-line 0.5 (Nil) 5 (Z) 3 (L) 1 (M) 3-wire (NPN) M9NV M9PV M9BV M9NWV M9PWV M9BWV M9N M9P M9B M9NW M9PW M9BW IC circuit 5 V,12 V 3-wire (PNP) 2-wire Reed switch Solid state switch 12 V Relay, PLC Grommet 24 V

Pilot port * Details of the mounting bolts P. 6 Stroke/Minimum stroke for auto switch mountings P. 15 Bore size Standard stroke [mm] 5 10 15 20 25 30 35 40 45 50 12 16 20 25 Applicable Auto Switches/Refer to the Web Catalog or Best Pneumatics for further information on auto switches.

Load voltage Wiring (Output) Pre-wired connector Applicable load DC AC Auto switch model Lead wire length (m) Indicator light Electrical entry Type Special function 5 (Z) Perpendicular In-line 0.5 (Nil) 1 (M) 3 (L) 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN equivalent) M9N M9P M9B M9NW M9PW M9BW M9NA1 M9NV M9PV M9BV M9NWV

Minimum Operating Pressure Symbol Rubber bumper Unit: MPa 12 16 20 25 Minimum operating pressure Bore size (mm) 0.03 0.02 Standard Stroke Bore size (mm) 12, 16 20, 25 Standard stroke (mm) 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 Replacement Parts: Seal Kit Theoretical Output OUT IN Unit: N Bore size (mm) Contents Kit no.

DSize: 50 to 100 Key M 5 x 0.8 x 25 50 CRA1L 50-Y-1Z M 8 x 1.25 x 35 63 CRA1L 63-Y-1Z M10 x 1.5 x 40 80 CRA1L 80-Y-1Z M12 x 1.75 x 50 100 CRA1L100-Y-1Z M12 x 1.75 x 50 +4 0 +4 0 0 0 9 *Size 30 does not include collars. * Remove the basic type mounting screws and use the mounting screws included in the foot bracket to secure the foot bracket to the cover.