A D A D Data symbol Correction factor Data symbol Correction factor Condition Condition A A Inlet air temperature Inlet air temperature 68F (20C) 1.36 86F (30C) 1.11 Ambient temperature Ambient temperature 77F (25C) 1.07 86F (30C) 1.00 B B C C Outlet air pressure dew point Outlet air pressure dew point 37.4F (3C) 0.50 41F (5C) 0.67 Inlet air pressure Inlet air pressure D F D F 145psi (1 MPa
Analog Voltage Output (1 to 5 V) Analog Current Output (4 to 20 mA) 5 20 Analog output [mA] Analog output [V] Model Max. rated flow value [l/min] Model Max. rated flow value [l/min] PFM710--C/E PFM725--C/E PFM750--C/E PFM711--C/E PFM710--D/F PFM725--D/F PFM750--D/F PFM711--D/F 10 10 (5) 1 4 25 25 (12.5) 50 50 (25) 00 0 0 100 100 (50) Max. rated flow value Max. rated flow value ( ): Fluid
BM2-032 BM2-040 D-C7, D-C8, D-H7 D-B5, D-B6, D-G5 D-A3A, D-A44A, D-G39A, D-K39A BM2-020 BM2-025 BA2-032 BA2-040 BA2-020 BA2-025 BM3-032 BM3-040 BM3-020 BM3-025 Caution Mounting Type and Accessories 1. Be careful of the snap ring springing out. When replacing the rod seal, take care that the snap ring does not spring out while you are removing it.
d C C B H B H Material: Carbon steel Material: Carbon steel Part no.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, "MGG, MGG, GUIDED CYLINDER, N lb
The series MGG guided cylinder is ideally suited for material handling applications involving stopping, lifting, and pushing. It combines the functions of a conventional cylinder, linear motion guide, and non-rotation device. Features include built-in shock absorbers, finite stroke adjustment, bumpers, and switch capability. Other features include: Slide or ball bushing bearings available
Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in), Mounting: B (Basic Style), Style: H (Air-hydro), Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: H (Air-hydro), Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Mounting: Both Ends Tapped, Bore Size: 32mm, Thread: Rc, Full Stroke: 250mm, First Stroke: 150mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: High speed / high frequency, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1.0, Port thread type: NPT, Auto Switches: M9B, Lead Wire Length(m):
Mounting: A (Both Ends Tapped), Bore Size: 32mm, Thread: Rc, Full Stroke: 250mm, First Stroke: 150mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Magnet: Built-in, Mounting: Basic Style, Style: Air-hydro, Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Air-hydro, Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: High speed / high frequency, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1.0, Port thread type: NPT, Auto Switches: M9B, Lead Wire Length(m):
Recommended tightening torque Auto switch model Recommended tightening torque [Nm] D-M9 0.05 to 0.15 D-M9A (Water resistant) 0.05 to 0.10 Fig. 8 D-F8 0.10 to 0.20 Set screw Auto switch 29 - Auto switch proper mounting position at rotation end Table 11 Auto Switch Rotation range / Actuation / most sensitive position A A A A B B B B D-M9 D-F8 Magnet Operation range at optimum set position (
Position code (Order #1 #4, Port A D) Message code #4 #3 #2 #1 D C B A 0 0 1 0 0 0 0 1 0 0 0 1 Message code 0x2 Product No.1 A port Ex.: Short-circuit or over current error with the first slave of COM A port. Message code and corrective action for diagnostic error are shown below.
Note3) L6 L8 Note 4) A2 M L7 L4 A1 Note 4) Weight (g) Note 5) Note 1) d D3 MAX.
Enter in order starting from the first station on the D side.