Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 125mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: Air Pressure Lock-up, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewied Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:
Select cable type and len gth surely. e xamp le S2S2Standard c able 2m+ d river LEC SS2 S2 Standard c able2m Nil Witho ut cab le and driver 100 to 120 LECSB1S B1 200 to 230 LECSB2S B2 100 to 120 LECSC1-S C1 *5 Mo tor cable and enc o der cable are included as a ccessories.
-B 40 W 50 L/min 1000 Hz 0.55 0.4 High speed response required for both ON and OFF -E 80 W 100 L/min 650 Hz 0.55 0.55 -F 40 W 100 L/min 550 Hz 0.7 0.55 -J 80 W 150 L/min 600 Hz 0.6 0.75 -K 40 W 150 L/min 500 Hz 0.8 0.75 * Current needs to be limited.
ZS-35-E Option Option Piping direction Part no.
Calculation: (Example) MUL32-100 Basic weight0.42 (Foot style 32 equiv.) Additional weight0.16/50 stroke Stroke 100 stroke 0.42 + 100 / 50 x 0.16 = 0.74 kg CQ2 RQ MU Construction D-X 20Data A A section MU25 Replacement Parts: Seal Kit Component Parts Bore size (mm) Kit no. Contents Description Note No.
200 300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
Calculation: (Example) MUL32-100 Basic weight0.42 (Foot style 32 equiv.)
"A" part's center is straightly pushed in by tools, such as pliers. e-con is cannot be reused once crimped for connection. For the connection failure such as incorrect order of wire and incomplete insertion, please use the new e-con for sensor. -49No.EX-OMI0001-I Specifications Specifications Item Specification Model No.
Blue e Power supply (Light terminal) N.C. N.O. q IFW50--75/76 e Color of lead wire Black Symbol Contact q w Power supply (Common) w Red Terminal (Relay terminal) 24 VDC Gray e Power supply (Light terminal) N.O. N.C. q IFW50--85/86 e Color of lead wire Black Symbol Contact q w Power supply (Common) White Terminal (Relay terminal) w 24 VDC Gray e Power supply (Light terminal) N.C. N.O.
How to Order Port Number e r KT10 R C 4P 4 1 0 0 Installation option Delivery pressure Code Installation Panel installation Delivery pressure Code 5 to 500 psig (0.034 to 3.4 MPa) 5 to 800 psig (0.034 to 5.5 MPa) 10 to 1500 psig (0.07 to 10.3 MPa) 15 to 2500 psig (0.1 to 17.2 MPa) 25 to 4000 psig (0.17 to 27.6 MPa) 50 to 6000 psig (0.34 to 41.4 MPa) 100 to 10 psig (0.7 to 69 MPa) 1) No code
Specifically, make sure that the spanner does not damage the connector. [ 100] 100 L/min (PFMB7201) Installation Fluid is flowing in the reverse direction by at least -5% of the maximum rated flow value.
500] 500 L/min(PFMB7102) [F 1][oU1] [1000] 1000 L/min(PFMB7202) 28 [ 25] 25 L/min(PFMB7501) [H_1] OUT1 [ 50] 50 L/min(PFMB7102) [100] 100 L/min(PFMB7202) [CoL] OUT1 [SoG] ONOFF [oU2] OUT2 2 [HYS] [2ot] OUT2 2 [2_P] [ 250] 250 L/min(PFMB7501) 2 [P_2] OUT2 [ 500] 500 L/min(PFMB7102) [F 2][oU2] 36 [1000] 1000 L/min(PFMB7202) [ 25] 25 L/min(PFMB7501) 2 [H_2] OUT2 [ 50] 50 L/min(PFMB7102) [100