SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2B16-45+45Z-B-XC10"

Description Material Note 1 Body Aluminum alloy Anodized 2 Branch passage PPS 3 Gasket HNBR 4 Sensor base PPS 5 Gasket HNBR 6 Sensor Au, Pt, Al2O3 Dimensions A B 70 H F E D 1.5 OUT IN 4 x P L K 2 x Port size N Symbol Model Port size A B D E F H K L N P PF3A703H Rc1, NPT1, G1 130 45 79.1 55.3 22.5 25 35 60 30 M4 x 0.7 depth 7 PF3A706H Rc1 1/2, NPT1 1/2, G1 1/2 170 60 94.1 70.3 30 68 45

Features 2 Model Selection 1 Obtain the correction factor for the temperature from data A or B and the correction factor for the air pressure from data C. Temperature Data A or B = Series IDU: Data A IDF1D to 240D: Data B-1 IDF 370B: Data B-2 Air pressure Data C = Series IDU and Series IDF: Data C 2 Calculate corrected air flow by using A or B and C.

Then the pressure in the pressure action chamber B falls to open the main valve C. When the coil o is not energized, the pilot valve A is closed and the pressure in the pressure action chamber B rises and the main valve C closes.

Construction/Parts/Dimensions AN05/10/20 AN15/30/40 No hexagonal part in AN05 and AN10 B Dimensions (mm) B Port size R, NPT A B D Model Sound absorbing material (Resin sintered body) AN05-M5 AN10-01 AN15-02 AN20-02 AN30-03 AN40-04 6.5 M5 x 0.8 15 Body (Resin) A 1/8 23 11 A 16 14 1/4 32 Hexagonal flats D 16.5 14 1/4 45 20 17 3/8 58.5 Port size 24 21 1/2 68 2 Silencer Compact Resin Type/One-touch

A B Easy manual unlocking Locked Unlocked Locking direction can be selected. Extension lock B A W Retraction lock W A B Various mounting brackets to accommodate wide range of applications.

Operation Instructions . 45 .. Outline of operation command . 45 .. Positioning operation . 45 .. Reset . 48 . Operation Examples . 49 .. Positioning operation . 49 Operation Mechanism. 50 . Positioning operation . 50 . Return to the origin . 51 . Response time in receiving an electric actuator input signal 52 1 - . Methods of interrupting operation . 52 Alarm detection . 53 .

M12 4pin LEC-CGD LEC-CGD c) M12 4pin LEC-CG1b) M12 4pin b) M12 4pin a) RJ45 8P LEC-CG1LEC-CG1a) RJ45 8P a) RJ45 8P No 1 LEC-CG1CN1 K 0.3m (LEC)CN4 L 0.5m 1 1m 2 LEC-CGD (LEC) 3 LEC-CG2K 0.3m L 0.5m 1 1m 4 M1 4 XS2C-D4 [] 120 1/4W 5 RJ-45 CN1 CN2 RJ-45 LEC-CAP-X22 27 - No a) RJ45 8P TM21P-88P HIROSE b) M12 4pin HR24-8DJ4PE550A(73) HIROSE XS2G-D4 [] c) M12 4pin

20.5 (28.5) A B 15 (22.5) A B 17.5 (25.5) A B 19.5 (27.5) A B 18 (26) A B 16 (24) B 20 27.5 27 24.5 31 25.5 27.5 29 27 24 30 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 18 (26) 16 (24) 25 30 29.5 27 31 25.5 27.5 29 27 24 30 22.5 (30.5) 21.5 (29.5) 15.5 (23.5) 18.5 (26.5) 20.5 (28.5) 19 (27) 17 (25) 32 33.5 33 30.5 32 26.5 28.5 30 28 25 31 25 (34) 24 (33) 18 (27) 21 (30) 33 (

Flow Characteristics/Weight Flow characteristics C [dm 3/(s bar)] b Cv C [dm 3/(s bar)] b Cv 1 2 (P A) 2 3 (A R) Valve model Weight (g) Pilot port size Type of actuation Port size SYJA512-M5 SYJA522-M5 0.12 0.18 0.39 0.45 0.47 0.66 0.14 0.18 0.45 0.45 N.C. 0.53 0.66 M5 x 0.8 Body ported 45 N.O. M5 x 0.8 SYJA514-01 0.32 0.46 1.1 0.32 0.41 1.2 75 (Without subplate 45) Rc 1/8 N.C.

A B For details about certified products conforming to international standards, visit us at www.smcworld.com.

A B For details about certified products conforming to international standards, visit us at www.smcworld.com.

A B For details about certified products conforming to international standards, visit us at www.smcworld.com.

A A A B A B P1 B B Section A-A (ejector) Section B-B (solenoid valve) Replacement parts list Parts list No. 1 2 3 4 5 6 7 8 Description Material No. Description Part No.

(60) Inlet air pressure psi (MPa) Correction factor 29.0 (0.2) 0.84 Data B: Ambient Temperature 43.5 (0.3) 0.87 Ambient temp.

W&F Contact B OUT6 N/A Output signal: OFF (open) for normal operation 4 OUT1 to OUT6 Contact A, B Output signal A: Contact A, B: Contact B Same as above Used to display the 5 [Enter] key MESSAGE screen to accept the setting. Used to display the MESSAGE screen to initialize the settings of RUN, REMOTE, and 6 [Initial] key OUT1 to OUT6. 7 [Cancel] key Used to cancel the setting.

Operation Instructions . 45 .. Outline of operation command . 45 .. Positioning operation . 45 .. Pushing operation . 48 .. Reset . 51 . Operation Examples . 52 .. Positioning operation . 52 .. Pushing operation . 53 Operation Mechanism.54 1 - . Positioning operation . 54 . Pushing operation . 54 . Return to the origin . 56 .

1 Direct Operated Solenoid Valve Metal Seal Series VS4 10 Model Flow characteristics Max. (1) operating cycle (cpm) (3) VK Response (2) time (ms) Weight (kg) Model Port size Rc (Nominal size) Number of positions JIS Symbol P A/B A/B EA/EB VZ C [dm 3/(sbar)] C [dm 3/(sbar)] b b Cv Cv AC DC AC DC AC DC VS4110-01 (6A) 3.2 3.2 0.42 0.37 0.86 0.80 1 8 2 (Single) 1,200 180 13 or less 45 or less

The "B"port can either be plugged or unplugged. Model Suitable tightening torque VQZ100 0.13 to 0.19Nm VQZ200 0.25 to 0.35Nm SY 5 port valve 3 port valve VQZ300 0.5 to 0.7Nm SYJ When port plug is used on B port, indicate "CM" in manifold part No. and port size, and supecify the port plug location on the manifold specification form.