*10 *10 *10 *10 *10 *7 For pipe thread type: NPT.

(guideline) Command 2400bps 19200bps 57600bps EE 145 25 10 EU 105 20 10 AB 105 20 10 MO 245 35 15 MD 115 20 10 OE 130 20 10 Calculation Example) Number of controllers connected: 5 Required transmission commands: EE,EU, AB Communication response time ( 25 + 20 + 20 ) x 5 = 325 ms Response time (guidline) 500 450 400 Response time [ms] EE 350 EU,AB,MD,OE 300 MO 250 200 150 100 50 0 1 2 3 4

(Example) SS3YJ7-20-03 . 1 set (manifold base) SYJ712-5LZ-01 . 2 sets (valve) SYJ700-10-1A . 1 set (blanking plate assembly) SS3YJ7-42R-03-01 . 1 set (manifold base) SYJ714R-5G . 2 sets (valve) SYJ700-10-2A . 1 set (blanking plate assembly) The asterisk denotes the symbol for assembly.

Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Supply the correct voltage of 12 to 24 VDC 10%. Incorrect power supply Check the wiring to the power supply.

and adjustment range of rotating time Rotating speed adjustment range having Size Allowable kinetic energy stable operation J s/90 10 0.00025 0.7 to 5 15 0.00039 20 0.025 1 to 5 30 0.048 40 0.081 Weight Table 3 Weight (g) Weight * Size 90 180 10 120 150 15 220 270 20 600 700 30 900 1100 40 1400 1600 * Values except weight of auto switch -19- Effective torque Effective torque (Nm) Operating

CC-Link (P.77) 4.2 (P.18)4.3 PLC (P.18)PLC 10 - 8() ()() () 9 10. (P.32) PLC 14.

0.4 MPa setting (Ex.)10-ARP30-02BG 0.005 to 0.4 MPa Set pressure range Note1) 0.2 MPa setting (Ex.)10-ARP30-02BG-1 0.005 to 0.2 MPa 0.6 MPa setting (Ex.)10-ARP30-02BG-3 0.008 to 0.6 MPa Within 0.2% F.S.

0.4 MPa setting (Ex.)10-ARP30-02BG 0.005 to 0.4 MPa Set pressure range Note1) 0.2 MPa setting (Ex.)10-ARP30-02BG-1 0.005 to 0.2 MPa 0.6 MPa setting (Ex.)10-ARP30-02BG-3 0.008 to 0.6 MPa Within 0.2% F.S.

140 100 95 90 85 80 75 70 65 60 Flow rate (l/min (ANR)) VAC side pressure (kPa) IRV20-C10 (One-touch fitting 10) IRV20 53.0 0 10 53.5 SET side pressure (kPa) 20 54.0 Set pressure (kPa) 30 54.5 40 55.0 50 55.5 60 56.0 70 Set point 56.5 80 90 57.0 100 95 90 85 80 75 70 65 60 0 50 100 150 200 250 Flow rate (l/min (ANR)) VAC side pressure (kPa) 2 Vacuum Regulator Series IRV10/20 Construction

24 VDC +10%/-10% Under-voltage detection approx. 18 VDC PWR(V) Operating voltage 24 VDC +10%/-5% Galvanic isolation Yes (between PWR and PWR(V)) Fieldbus Bus protocol PROFINET I/O Version PROFINET Specification Version 2.3 Conformance Class C Yes (Only for IRT switch function) FSU (Fast Start Up) Yes MRP (Media Redundancy Protocol) Yes MRPD (Media Redundancy for Planned Duplication) Yes

Usable range 20 30 40 50 50 40 30 20 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 10 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Distance from cylinder shaft center: L0 (cm) Distance from cylinder shaft center: L0 (cm) Note: 1N = 0.2248lbf 1kg = 2.2046lb 1in = 25.4mm 1in = 2.54cm 100 80 REA63 REA50 50 40 30 REA40 REA32 20 Load weight W (kg) REA25 10 1 100

MPa 5.0 MPa Rated pressure range 2.0 MPa 1.0 MPa 1.6 MPa 1.0 MPa Withstand pressure 1.5 MPa 2.4 MPa 3.0 MPa 5.0 MPa 12.5 MPa 30 MPa Power supply voltage When used as a switch output device 12 to 24 VDC 10% with 10% voltage ripple or less When used as an IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Temperature characteristics 2% F.S. (25C standard) 3% F .S.

Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% PS port 2(B) Vacuum pad port Flow Characteristics Response Time Flow Characteristics (When restrictor is fully open) 2(B)3/5(E) 1(P)2(B) b 0.19 Cv 0.05 C [dm3/(sbar)] 0.40 b 0.18 Cv 0.10 C [dm3/(sbar)] 0.24 Valve model Fluid passage 2(B) Port size M5 Valve model Response time ms (at 0.5 MPa) SJ3A6-ll-l

LED display.31 9. 1 LED display.31 9. 2 Controller IF communication status and LED display.32 10. Mode.33 10. 1 Outline.33 10. 2 Step data input mode .33 10. 3 Numerical data input mode.33 10. 4 Data writing mode.35 11. Memory map .36 11.1 Memory assignment.36 11.2 Controller IF flagIN Data.40 11.3 Gateway unit status flagIN Data.40 11.4 Gateway unit control flagOUT Data.42 12.

Manual unlocking P14 10. Maintenance P16 10-1. Disassembly/ Replacement 10-2. Maintenance 10-3. Construction 11. Auto switch P19 11-1. Applicable auto switches 11-2. Minimum auto switch mounting stroke 11-3. Auto switch proper mounting position (detection at stroke end) and its mounting height 11-4. Auto switch operating range 11-5.

The allowable voltage fluctuation rate is 10% of the rated voltage value for both AC and DC.

0.31 0.28 0.31 0.28 U W M5 x 0.8 U W 597 4 Port Direct Operated Poppet Solenoid Valve 10-VQD1000 Dimensions L plug connector: 10-VQD1121-L-M5 M plug connector: 10-VQD1121-M-M5 Directional Control Valves Air Grippers Modular F.