Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/Flow Adjustment

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Panel Mount Adapter for w/o Flow Adjustment

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Panel Mount Adapter for w/Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type), Bracket: None, Operation Manual: K (Operation Manual, Calibration Certificate)

Series: 25A-PFM7, Flow Rate Range: 10 [0.2 to 10 (5) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option

Series: 25A-PFM7, Flow Rate Range: 25 [0.5 to 25 (12.5) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber),

The ZSE40A(F) series is a high precision digital pressure switch, providing improved functions, performance and variations over the previous ISE40 series.? Abnormal values can be seen at a glance on the 2-color display.? The settings of the master pressure switch can be copied to up to 10 slave pressure switches, reducing the setting work, and preventing mistakes in setting.? Other features

The ZSE40A(F) series is a high precision digital pressure switch, providing improved functions, performance and variations over the previous ISE40 series.? Abnormal values can be seen at a glance on the 2-color display.? The settings of the master pressure switch can be copied to up to 10 slave pressure switches, reducing the setting work, and preventing mistakes in setting.? Other features

SMCs PFM dual color digital flow switch was?developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.? The series is incredibly compact and lightweight compared to existing flow sensors.??The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, IFW/PFW 1/8INCH PT VERSION, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CB, IFW/PFW 1/8INCH PT VERSION, 0.67196 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CB, ISE40/50/60 1/8" NPT VERSION, 0.33918 lb