Base Mounted Wiring: Individual Pilot EXH, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 3 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 3/8, Thread: NPT, Control Unit: None, Voltage of Air Release Valve: w/o Air Release Valve, Q: CE Marked
Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 3 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: NPT, Control Unit: None, Voltage of Air Release Valve: w/o Air Release Valve, Q: CE Marked
Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 3 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: G, Control Unit: None, Voltage of Air Release Valve: w/o Air Release Valve, Q: CE Marked
Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 3 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: NPTF, Control Unit: None, Voltage of Air Release Valve: w/o Air Release Valve, Q: CE Marked
Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: One-piece Junction Cover, Stations: 3 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: NPTF, Control Unit: Air Release Valve, Blank Plate for Filter Regulator, Voltage of Air Release Valve: 24VDC, Q: -
Base Mounted Wiring: Individual Pilot EXH, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 3 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 3/8, Thread: NPTF, Control Unit: None, Voltage of Air Release Valve: w/o Air Release Valve, Q: CE Marked
Stations: 3 Stations, Piping: 1 (P Common, R Common, A Side)
Stations: 3 Stations, Piping: P Common, R Common, A Side, Thread: -, Option: -, CE/UKCA Compliant: -
.: 01 (ø1/8"), Actuator Type: 02 (One way Roller Lever), Suffix: S (Hard Steel Roller)
.: 01 (ø1/8"), Actuator Type: 02 (One way Roller Lever)
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CONTROLLER, INLINE TYPE, AIRLINE EQUIPMENT, AS FLOW CONTROL, FB, AS 1/2INCH STANDARD (PT), .50080 lb, ModelPort sizeFree flowControlled flowApplicable cylinder bore size
NZX is available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, NZX MANIFOLD, VACUUM SERIES, ZZX1 MANIFOLD UNIT, JD, ZZX1 1/8 PORTED, .65120 lb
Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch, FLOW CONTROL W/FITTING *LQA, AIRLINE EQUIPMENT, AS***F 1/2INCHSTANDARD (NPT), .21958 lb
Available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, MANIFOLD ASSY, 3-STA, VACUUM EJECTOR, 205 lb
mode lower side set value 12 Wind mode upper side set value 13 Wind mode hysteresis OUT2 14 Accumulated output mode 15 Accumulated pluse output mode 16 Err mode 17 oFF mode 18 Flow bottom value 19 Flow peak value 20 Accumulated flow value 21 Switch output mode/communication mode display SIO mode/SDCI mode display -87No.PF-OMZ0002-A [Line name communication data] Value (16 hex number) 00 01
02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F Display letter 7seg 11seg Value (16 hex number) 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F Display letter 7seg 11seg Value (16 hex number) 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F Display letter 7seg 11seg Supplementary information When is displayed, a reject response will be sent. -84No.PF-OMY0002 Troubleshooting If an operation failure
02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F number) Display letter 7seg 11seg Value (16 hex 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F number) Display letter 7seg 11seg Value (16 hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F number) Display letter 7seg 11seg -84No.PF-OMX0002-B Troubleshooting If an operation failure of the product occurs, please confirm the cause of the troubles
02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F number) Display letter 7seg 11seg Value (16 hex 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F number) Display letter 7seg 11seg Value (16 hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F number) Display letter 7seg 11seg -49No.PF-OMX0007-A Specifications Models PF3A701H PF3A702H Applicable fluid 1 Air, N2 Fluid Operating fluid temperature 0
Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :