N.O. 125 VAC 15 15 4 2 10 10 4 2 250 VAC 15 15 3 1.5 10 10 3 1.5 8 VDC 15 15 3 1.5 15 15 5 2.5 15 15 3 1.5 10 10 5 2.5 14 VDC 30 VDC 3 6 6 1.5 5 5 5 2.5 125 VDC 0.5 0.5 0.3 0.3 0.05 0.05 0.05 0.05 250 VDC 0.25 0.25 0.2 0.2 0.03 0.03 0.03 0.03 16-12-6 2 Paddle Style Flow Switch Series IF3 Fluid and Ambient Temperature Range Enclosure Open type Using indoors away from water drop.
LCD 4.DIN 30mm 30mm 10 - 2-2 30mm No. 2-3 (1), (Err6), 1 ML2B25 15 ML2B32 19 ML2B40 24 2-4 5mm 5-10-15 5mm Err5 4.2 5 10 15 20 1.0 1.0 1.0 1.0 5.8 5mm30mm Err6: 20 30 100mm/sec :50cm :0.5MPa 11 - 3 3 3 3 ML2B+CEU2 NO 1 () () YES NO () YES NO YES YES NO YES NO YES YES NO NO NO YES A 12 - A 1.
CW CW 10 10 2 R 330 CCW input 330 CCW input 2 2 9 1 CCW CCW 8 9 9 5 4 14 13 12 R 330 PD input 1 PD 8 11 F Functions Function change-over switch Input signal terminal CW pulse input terminal By applying the pulse input, the actuator moves from the motor side to the end side.
Standard Stroke 2 , 3 , 4 , 5 , 6 , 8 , 1 0 2, 3, 4, 5, 6, 8, 10 5, 10, 15,20,25,30 5, 10, 15,20,25,30,40 5, 10, 15, 20,25, 30, 40 5, 10, 15,20,25,30,40 1 kg=2.2 16. Magnetic Holding Power (lbs) 1N=0.101 H 227.94 L type 140.65 Basicweight. -. -. 8.00 lb6) Additional weight.. . 0.30/1 inch !
Standard Stroke 2 , 3 , 4 , 5 , 6 , 8 , 1 0 2, 3, 4, 5, 6, 8, 10 5, 10, 15,20,25,30 5, 10, 15,20,25,30,40 5, 10, 15, 20,25, 30, 40 5, 10, 15,20,25,30,40 1 kg=2.2 16. Magnetic Holding Power (lbs) 1N=0.101 H 227.94 L type 140.65 Basicweight. -. -. 8.00 lb6) Additional weight.. . 0.30/1 inch !
-150 JC32-10-100 JC40-12-125 JC40-12-150 JC40-12-175 JC50-16-150 JC63-16-200 8 10 10 12 12 12 16 16 1 1.5 1 1.25 1.5 1.75 1.5 2 D-X Technical Data 1139 JC Series Dimensions of Accessories Rod end nut (mm) d: Thread nominal size Model Order number M8 x 1 M8 x 1.25 M10 x 1 M10 x 1.25 M10 x 1.5 M12 x 1.25 M12 x 1.5 M12 x 1.75 M14 x 1.5 M16 x 1.5 M16 x 2 M18 x 1.5 H 5 5 6 6 6 7 7 7 8 10 10 11
Bore d C B H NTJ-015A 10 16 8.1 9.2 7 8 3.2 4 M4 X 0.7 NTJ-010A M5 X 0.8 * Refer to p.1.3-12 for details of the mounting nut. (mm) ND NN Bore 10 16 A B C D F GA GB H MM NA NB S Z 0 0.022 0 0.022 15 12 14 4 8 8 5 28 M4 X 0.7 12.5 9.5 M8 X 1.0 46 74 75 8 15 18 20 5 8 8 5 28 M5 X 0.8 12.5 9.5 M10 X 1.0 47 10 Refer to p.1.3-8 to 1.3-10 for dimensions of each mounting bracket.
AS321FE AS331FE AS421FE AS431FE Model 8 10 6 8 10 12 12 10 6 8 10 Tubing O.D.
Model XT13-394-06 XT13-394-10 INA-48-1-06 INA-48-1-10 INA-48-16-10 INA-48-16-06 INA-48-58-10-H INA-48-58-06-H Port size Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Relief mechanism Non-relief Relief Non-relief Fluid Deionized water (Pure water) Air, N2 Proof pressure 1.9 MPa 1.5 MPa Max. operating pressure 1.3 MPa 1.0 MPa Set pressure 0.1 to 1.0 MPa 0.05 to 0.5 MPa 5 to 60C Ambient and fluid
The voltage variation must stay within the 10% to +10% range of the rated voltage. In case importance is attached to response characteristics due to use of a DC power source, keep the variation within the 5% to +5% range. The voltage drop is the value at the lead wire to which the coil is connected.
10 8 5 4 ZZMA Stations 04 ZQ 10 10 8 6 ZZMA Stations 04B Effective area of external silencer is 160 mm2.
Service life cycles (10 thousand) Operating pressure (Pa) Leakage (Pam3/s) Effective area (mm2) Model Valve type Piping size Orifice (mm) Internal External Fitting P.523 For VCR 1.3 x 10-11 XVD2-02V 50 0.2 MPa (G) to 1 x 10-6 5 x 10-9 1.3 x 10-11 Single acting (N.C.) 1/4 3 Main air supply: 4.6 Initial air supply: 0.2 to 4.6 Values at normal temperature, excluding gas permeation to For Swagelok
Max. 10 VZ VS VFN Mounting bracket (A port) P = 26 L Dimension n: Stations n L L1 L2 Formula L1 = 26 x n + 36 L2 = 26 x n + 10 2 88 62 3 114 88 4 140 114 5 166 140 6 192 166 7 218 192 8 244 218 9 270 244 10 296 270 [ ]: With light/surge voltage suppressor 4-7-7 8 Series VT307 Dimensions: Individual Exhaust (Interchangeable with VT301 for mounting) VV307-01-3--F P = 26 (Applicable cable O.D
Note) A/B port piping: Rc 3/8 or Rc 1/2 Option VFS 9 Other Base specifications Individual EXH VS4 1 2 Individual EXH Common EXH Valve stations 02 2 stations VQ7 10 10 stations EVS How to Order Manifold Assembly VFN Specify the valves and blanking plate to be mounted on the manifold along with the manifold base model no.
R . 10-1 10.1 . 10-1 10.2 . 10-1 10.3 . 10-2 11 T . 11-1 11.1 . 11-1 11.2 . 11-1 11.3 . 11-2 11.4 . 11-3 11.5 . 11-4 12 V . 12-1 12.1 . 12-1 12.2 . 12-1 12.3 . 12-2 13 . 13-1 13.1 . 13-1 IDFC60/70/80/90 Series IDX-OM-W095 1 1.1 () 6.2 1.1.1 3 IDFC60/70/80/90 Series 1-1 IDX-OM-W095 1.2 6 1.2.1 1.2.2 50 1.2.3 0 IDFC60/70/80/90 Series 1-2 IDX-OM-W095 1.2.4 IDFC60/70/80
2 1 P0.01MPa P0.01MPa P0.01MPa 2 1 0.5 0 2 4 6 8 10 0 0 0 2 4 6 8 10 0 0 2 4 6 8 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Number of needle rotations Number of needle rotations Number of needle rotations Construction t r w e With reducer q i A y u y u Part
A 40 44 B 20 22 C 9 10 D 22 24 E 59 66 F 33 34 G 24 25 H 30 40 J 36 46 K 6 9 M 45.5 50.5 N 69 76 VVXA31 VVXA32 17-3-108
: 201 to 300mm 80 40 50 50 20 20 Load weight m (kg) Load weight m (kg) Load weight m (kg) 20 10 10 10 63 63 63 5 5 5 50 50 50 [Example ] 40 40 40 1 1 1 70 100 300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.
Refer to external dimensions in pages 3-2-4 to 3-2-10, and then mount it. VFN 48 V DC None Z Precautions Plug a connector in or out vertically, never at an angle. How to Calculate the Flow Rate S 6 V For obtaining the flow rate, refer to page 3-1-10.
(mm) H2 Q P L W H1 Model TMA-06 TMA-08 TMA-10 TMA-12 28 21.7 172.5 31.8 25.4 151.2 35 28.1 167.3 37 19 151 17.9 20.3 24.3 26.7 18.6 18.6 22 22 11.4 12.6 15 16.2 6 12 10 8 15-6-32 1 Related Products: Tube Cutter Series TK Tube Cutter: TK-2 Possible to cut a tube up to 18 mm.