position, tighten the M3 mounting screw to secure the auto switch by making the bottom face of auto switch attached to the cylinder tube.

H Section AA TH (Head height of mounting bolt) +0.03 0 RL 10 10 T TB +0.03 0 R RH Detail of part U Q QL (n x 1) x Q B -Mounting reference planes D PR PR max18 B B PH PH Type of centralized piping on one side without switch rail Type of shock absorber (Only for MXY12) FH FW MA L LA M HR J JH F FL H HA MM MB Model M5 x 0.8 (Width across flats 2.5) MXY6 24 8.5 32 28 M3 x 0.5 18 0.5 60 20 3 12

VXFC06D VXFC10D VXFC06D-6 VXFC10D-6 Number of outputs 6 10 6 10 Common 6 in 1 10 in 1 6 in 1 10 in 1 Common common common common Power supply voltage 24VDC to 48VDC 5% 12VDC 5% Load output voltage *1 24VDC to 48VDC 12VDC Same as the input power Same as the input power supply voltage. supply voltage.

Prevent the stoppage of rotating parts (pins, etc.) by applying grease. 10)Do not use the product until you have verified that the equipment can operate properly.

10 Air Slide Table Long Stroke Type Series MXY Construction @3 y w q r u #0 MX MTS !

Note Lead wire length: 2m With mounting screws (M3 x 5L: 2 pcs.)

Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) GWP: 20887 Refrigerant charge [oz (g)] 13.7 0.4 (390 10) 18.7 0.4 (530 10) 22.2 0.4 (630 10) 27.5 0.4 (780 10) Auto drain Float type (Normally open, Min. operating pressure: 14.5 psi (0.1 MPa)) Port size Symbol N NPT1 NPT1 1/2 NPT2 Symbol Nil R1 R1 1/2 R2 Drain tube O.D.

(mm) 10 9 8 7 6 5 4 3 Manifold stations n L1 L2 2 180 165 150 135 120 105 90 75 60 235.5 223 198 185.5 173 160.5 148 123 110.5 8

Part number Description Remarks ZS-28-A Power and output lead wire and connector Length: 2 m ZS-28-B Bracket Mounting screw (M3 x 5 L) 2 pcs. ZS-28-C Sensor connector 1 pc. ZS-27-C Panel mount adapter Mounting screw (M3 x 8 L) 2 pcs. ZS-27-D Panel mount adapter + Front protective cover Mounting screw (M3 x 8 L) 2 pcs.

Fig. 9 Normal output OFFt0 Fig. 10 Sequence OFF0 Fig. 11 Sequence 6. Cascade connection There are only outputs up to 10 points (6 points in the case of VXFC06A) on a single board. However, it is possible to increase the output points by cascading (multiple board connection).

/ 0 MEMO h (h) IDF100150F 4-2 4 4 IDX-OM-U021 4 , OFF [] IDF100150F 4-2 4 5 IDX-OM-U021 4 (+,-) 0 IDF100150F 4-2 4 6 IDX-OM-U021 5 5 5-1 3 ON OFF (R) OFFON 3 2 R T 5.2 60cm 1 5.2 5.2 10% 5.2 IDF100150F 5-1 5 1 IDX-OM-U021 5 ( ) ( ) 60cm 1 10% 3 ( ) 60cm 1 2 IN OUT INOUT () 424 IDF100150F 5-1 5 2 IDX-OM-U021 5 5-2 1-3 51 3.6 OFF () ON OFF ON IDF100150F

Free flow Controlled flow Model Port size Applicable cylinder bore size (mm) Effective area (mm2) Effective area (mm2) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Weight (g) 4.7 AS1000-M3 M3 x 0.5 20 0.3 20 0.3 2.5, 4, 6 33 AS1000-M5 M5 x 0.8 90 1.4 80 1.2 6, 10, 16, 20, 25 90 AS2000-01 1/8 340 5.2 250 3.8 20, 25, 32, 40 115 AS2000-02 1/4 340 5.2 250 3.8 130 AS3000-02 1/4 810 12.3 810 12.3

Calculate (1) (Wmax) from the graph of max. payload (W1, W2, W3) and calculate (2) and (3) (Mmax) from the maximum allowable moment graph (M1, M2, M3).

Calculate (1) (Wmax) from the graph of max. payload (W1, W2, W3) and calculate (2) and (3) (Mmax) from the maximum allowable moment graph (M1, M2, M3).

Calculate (1) (Wmax) from the graph of max. payload (W1, W2, W3) and calculate (2) and (3) (Mmax) from the maximum allowable moment graph (M1, M2, M3).

Terminal block For wiring, please refer to P.2-5 10,11Remote control 12,13Operation 14,15Failure R,S,T: Power supply PE: Ground 15 14 13 12 11 10 R S T To the users machine To the users machine Terminal connecting screw: M3 Terminal connecting screw: M5 Crimped terminal width: 6.5mm or less Crimped terminal width: 13mm or less Applicable electric wire: 8mm 2 or more Applicable electric wire

OFF M3 hexagon screw Tightening torque 0.6 Nm 1 2 0 0 0 IP address 192.168. Y . X : Thread size: M3 x 30 The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result.

M3 hexagon screw Tightening torque 0.6 Nm Terminating resistor Valve manifold : Thread size: M3 x 30 Troubleshooting The following instructions must be followed during maintenance: Turn off the power supply. Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance. Otherwise an injury can result.