300 400 200 VXB215 B E(H) 100 300 400 500 600 200 VXB215 C F(H) 100 300 400 500 600 700 800 200 Flow rate Q [kg/h] How to read the graph The sonic range pressure to generate a flow rate of 300 kg/h is P1 0.3 MPa for the VXB215C F(H).
, 125, 150, 200 201 to 350 D25 32 40 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200, 250, 300 -X Intermediate stroke is available, too.
Applicable stroke table Standard Model Stroke (mm) 100 200 300 400 500 600 700 800 900 1000 Manufacturable stroke range [mm] LEFS16 100 to 400 LEFS25 100 to 600 LEFS32 100 to 800 LEFS40 200 to 1000 Strokes are manufacturable in 1 mm increments. Refer to the manufacturable stroke range. However, strokes other than those shown above are produced as special orders.
Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer
(packaged together) 50 80 650 F 40 550 G 10 300 H 4 200 J Filter (IN port) 100 Nil Without lter F With lter Note) Note) Flow reduction rate 50 L/min: 5% or less 100 L/min: 5 to 10% 150 L/min: 10 to 15% 80 600 K 40 500 L 10 250 M 4 150 150 Specications Flow rate (L/min) [at 0.25 MPa] 50 100 150 Power consumption (W) 80 40 10 4 80 40 10 4 80 40 10 4 Type of actuation 2-position 2 port N.C.,
10 10 11 B C 15 15 19.6 19.6 19.6 21.9 21.9 21.9 25.4 27.7 27.7 31.2 JC20-8-100 JC20-8-125 JC32-10-100 JC30-10-125 JC25-10-150 JC40-12-125 JC40-12-150 JC40-12-175 JC40-14-150 JC50-16-150 JC63-16-200 JC63-18-150 DA00207 DA00169 DA00141 DA00142 DA00140 DA00145 DA00146 DA00143 DA00148 DA00151 DA00150 DA00153 13 13 17 17 17 19 19 19 22 24 24 27 Spare parts Rod end nut The basic type has one rod
Single-phase 200 VAC (50 Hz) Single-phase 200/220 VAC (60 Hz) 20 Options and Available Combinations (Size/Option) A C G K L R T V Symbol Note 2) Nil With heavy duty auto drain (Applicable to medium air pressure) With terminal block for run & alarm signal Timer type solenoid valve with auto drain (Applicable to medium air pressure) With Chinese labels and a Chinese operation manual Option
Where the load voltage is 100/200 VAC. Therefore, use a contact protection box with the switch for any of the above cases: The contact life may be shortened (due to permanent energizing conditions.) D-A72(H) must be used with the contact protection box regardless of load types and lead wire length since it is greatly affected by loads.
Suitable 20 for m and 0.7 for . 1000 ML2B 6 10 15 20 25 30 40 50 63 80 100 125 140 160 180 200 250 300 0.057 0.099 0.113 0.120 0.184 200 300 400 500 E1 4.9 J In the case of cylinder stroke at load and free horizontal impact, 0.157 0.274 0.314 0.334 0.511 C J G5-S E1 or E substitute respective figures for Data A in order to calculate E1. 100 Impact object weight m or corresponding weight
1 V7 LEFS 32 200 R H B B 3 M2 S r Motor type e Motor mounting position w Size q Accuracy Nil Basic type H High precision type 25 32 40 Nil In-line R Right side parallel L Left side parallel Symbol Type Output [W] Size Compatible driver V6 AC servo motor (Absolute encoder) 100 25 LECYM2-V5/LECYU2-V5 V7 200 32 LECYM2-V7/LECYU2-V7 V8 400 40 LECYM2-V8/LECYU2-V8 u Motor option t Lead [mm] i Cable
Controller JXC2 Main control power supply 24 VDC 120.3 120.3 mm mm 200 200 mm/s mm/s To USB Port To USB connector 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 or To CPWR connector USB Cable PC JXC3 -3- 3. Connection Check Connect the USB cable, and supply power to the controller.
Controller Main control power supply 120.3 120.3 mm mm 200 200 mm/s mm/s 100 500 100 500 1 1 24 VDC 200 1000 200 1000 2 2 To USB Port To USB connector 50 200 50 200 3 3 USB Cable PC To CPWR connector -3No.SFOD-OMT0008 3. Connection Check Connect the USB cable, and supply power to the controller.
Unique air cushion construction with no cushion ring, Wide size variations from °20 to °100, Nearly three times the allowable kinetic energy, Improved noise reduction * and repeatability, Interchangeable mounting, CYL, 3-POSITION, SW CAPABLE, ACTUATOR, RZQ 3-POSITION CYLINDER, LC, 32MM RZQ OTHERS (COMBO), 2.866 lb
H 4 S y m b o l consumption (W) 100 VAC 200/40 Initial power / Power 200 VAC 800/40 Heater assembly number XLA25-60S-1 XLA25-60S-2 No. of heater assemblies 1 pc. 1 pc. H 5 100 VAC 200/40 400/70 Initial power / Power consumption (W) 200 VAC 800/40 1600/80 Note 1) Initial power and power consumption are nominal values. The heaters are PTC thermistor type design.
LEY25: 200 or less LEY32: 100 or less 3. In case of [Double clevis], use the actuator within the following stroke limit. LEY16: 100 or less LEY25: 200 or less LEY32: 200 or less 4. G Head flange is not available for LEY32. Nil 1 3 5 8 A B C Without cable 1.5 3 5 8 !
200 When 20 units are used 77% reduction Current model IR3000 Series 91% reduction 38000 yen reduction 150 150 117000 yen reduction Current model IR1000 Series IR2000 Series 100 100 IR1000-A Series IR2000-A Series IR3000-A Series 50 50 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Units used Units used Released into atmosphere IR Special bleeding structure No fixed throttle in the new design.
100 400 200 400 200 Actuator specifications Pushing speed[mm/s] 20 to 30 10 to 30 5 to 30 20 to 30 10 to 30 20 to 30 10 to 30 Max. acceleration/deceleration[mm/s2] 5000 Positioning repeatability [mm] 0.01 Lost motion[mm] *4 0.1 or less Screw lead[mm] 10 5 2.5 12 6 16 8 Impact/Vibration resistance[m/s2] *5 50/20 Actuation type Ball screw (In-line) Ball screw + Belt (parallel) Guide type Linear
Male thread Proper tightening torque Nm Width across flats mm Nominal size of adjustable angle wrench mm M5 1/6 turn after hand tightening 8 100 12 17 19 24 7 to 9 12 to 14 22 to 24 28 to 30 1/8 1/4 3/8 1/2 150 200 200 200 Lock Nut Tightening Torque Caution 1. The proper tightening torque for the hexagon lock nut is as shown in the table.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VZS VFS VS4 VQ7 EVS Large capacity EVS7-6 (Size 1) 1200 l/min (ANR) EVS7-8 (Size 2) 3000 l/min (ANR) EVS7-10 (Size 3) 5500 l/min (ANR) VFN Cylinder driving size Flow rate 100 160 200 Rubber seal, single type Lightweight Size 1 (3 position): 0.55 kg Size
How to Order Pilot Valve Assembly 1 G 00 VT3112 Rated voltage Electrical entry Note) 1 100 VAC, 50/60 Hz Grommet G 2 200 VAC, 50/60 Hz Note) Even if the electrical entry of the solenoid valve is T, D, TL, or DL, the electrical entry for pilot valve assembly is chosen for G. 3 110 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option 3-6-1 2 Series VP450