procedure of Initialize mode 21 Function selection mode 26 Default settings 26 F_1 Input procedure of the Set value of instantaneous output 27 F_2 Input procedure of the Set value of instantaneous output (Auto-preset) 28 F_3 Input procedure of the Set value of accumulated output 29 Key-lock function 31 Maintenance 32 Troubleshooting 33 Cross-reference for troubleshooting 33 Error indication 35
When 5 minutes interval is selected, take into consideration the maximum number of times it is possible to write to the memory device (electronic part), which is 1 million times (In case of 24-hour communication, 5 minutes access cycle (1 million cycles) = 18.50 million = approx. 35 years).
HRR Series 5.5 Advanced setting mode 5-35 HRX-OM-W002 Chapter 5 Display and Setting of Various Functions Set value Contents Initial value OFF Alarm is not generated. WRN Operation of this product will continue when the alarm occurs. Setting for electric conductivity rise alarm 9. Press the [] key. Displays screen for setting value of electric conductivity rise alarm threshold.
External stopper 35 Mounting position of external stopper 36 Maintenance and Inspection 36 Regular inspection 36 Replacement procedure of the seal kit Troubleshooting 42 -1- Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
INP Byte2, bit6=ON Held Byte2, bit4-5=OFF Byte3, bit0-7=OFF External lock Unlock (4) Input Byte5, bit0-1: Movement Speed mode and Byte6-35:Numerical operation data. E.g.)
CN5I/O .23 6.1 /.23 6.2 /(NPNPNP ).23 (1) I/O (NPNPNP ).23 (2) I/O .23 63 /.24 64 I/O .27 7 .28 71 .28 72 .31 73 .33 8 .34 81 .34 82 .34 83 .35 1 .35 2 (.35 3 .35 84 .36 85 .36 9 .37 91 .37 92 .38 10 .39 101 .39 102 I/O .39 1 .39 2 .40 3 .41 4 HOLD.42 5 .42 2 - 6 .42 7 .43 11 .44 111 [5m ].44 112 [820m].44 113 [5m ].45 114 [820m] .45 115 I/O .46 116 .46 117 .47 12. .48 12.1 .48 12.2 .49 13
Specifications 35 Specifications 35 Dimensions 36 Output Unit Summary of Product Parts 37 Mounting and Installation 38 Installation 38 Wiring 39 Specifications 42 Specifications 42 Dimensions 42 -1No.EX-OMI0001-I Input Unit Summary of Product Parts 43 Mounting and Installation 44 Installation 44 Wiring 46 Specifications 50 Specifications 50 Dimensions 50 Maintenance 51 Troubleshooting 52
KQ2P06 Model and Dimensions Symbol Applicable size d A L D Weight (g) Note 06 6 18 35 8 1 White 08 8 20.5 39 10 2 White 07 1/4 18 35 8.5 1 Orange 09 5/16 20.5 39 10 2 Orange When existing product is used, please be careful with the interchangeability between existing product in the table below and ZK2A.
dimensions Model V AL10-A AL20-A 30 27 22 5.4 8.4 40 2.3 28 AL30-A 41 35 23 6.5 13 53 2.3 30 AL40-A 50 52 26 8.5 12.5 70 2.3 35 AL40-06-A 50 52 25 8.5 12.5 70 2.3 34 AL50-A 70 66 35 11 13 90 3.2 47 AL60-A 70 66 35 11 13 90 3.2 47 Semi-standard specifications Drain cock with barb fitting Metal bowl Metal bowl with sight glass Metal bowl with sight glass and drain cock With drain cock Metal
Stroke [mm] Origin 25mm CCW CW -25 -20 -15 -10 -5 0 Stroke [mm] Origin 25mm CCW CW -15 -10 -5 0 5 10 Stroke [mm] Origin 25mm CCW CW -35 -30 -25 -20 -15 -10 Stroke [mm] 31 - Initial setting for the ORIG parameters Refer to the controllers (LEC series) operation manual for detail.
Workpiece weight: 0.05 kg 25 20 0.5 Gripping force (N) 0.4 15 13 0.3 10 0.2 5 0.1 0 20 30 40 50 60 70 Gripping point L (mm) When MHY2-16D is selected, the gripping force is determined to be 13 N according to the gripping point distance (L = 35 mm) and the pressure (0.6 MPa).
Applicable cylinder ML2B25 ML2B32 ML2B40 MY-S25A 35 50 8 5 9.5 5.5 M6 x 1 B MY-S32A 45 64 11.7 6 11 6.6 M8 x 1.25 B Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load. In such a case, use a side support in the middle section.
operating range 10 34.5 35.5 14.5 15.5 Stroke (mm) Auto switch operating range 10 30.5 31.5 18.5 19.5 Model Model 5 25.5 26.5 13.5 14.5 A B C D A B C D 11-/22-MXP 6 3 11-/22-MXP 6 5 11-/22-MXP10, 12, 16 Electrical entry from outside Electrical entry from inside Parallel electrical entry B A B B A A Solid state switch D-M9B, D-M9N Reed switch D-A93 (mm) (mm) Stroke (mm) 20 41 29 47 35
Contact protection box OUT(+) Brown [Red] Lead wire length: 0.5m 7 7 6 7 8 8 Resistor Reed switch Lead wire length: 3m 35 35 30 35 41 41 Zener diode CD-P11 OUT() Blue [Black] Contact Protection Box CD-P12 Blue [Black] D-A96(V) Contact protection box internal circuits Type D-A9 switches do not have built-in contact protection circuits.
Driver Energization type Divisions per rotation Full step 200 LC6D-220ADHalf step 400 Full step 500 LC6D-507ADHalf step 1000 Dimensions 100 97 52 42 Operation window 35 38 96 35 Label DIN rail holding plate Connectors (included) [Manufacturer: Molex Japan, Co., Ltd.] Quantity Description Part no.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.4 15 13 0.3 10 0.2 5 0.1 0 20 30 40 50 60 70 Gripping point L (mm) When MHY2-16D is selected, the gripping force is determined to be 13 N according to the gripping point distance (L = 35 mm) and the pressure (0.6 MPa).
A 1 2 150 165 42.7 76.3 45 65 40 60 35 40 80 80 ALBA90-10 ALBA90-20 1.17-24
40 45 45 55 9 12 13 13 16 16 12 16 20 20 25 30 32.5 38 46.5 56.5 72 89 46 52 65 75 95 114 10 14 18 18 22 26 22 30 35 35 40 40 Wl Stroke range (mm) Bore size (mm) ZZ S ZZ WL W V S RF P NB N MO 32 40 50 63 80 100 up to 500 up to 500 up to 600 up to 600 up to 750 up to 750 151 165 180 180 226 226 100 110 118 118 150 150 143 152 168 168 208 208 24 24 24 24 40 40 6.5 9 10.5 12 14 15 4 4 5 9 11.5
Features 1 position within the entire stroke Low profile with compact lock unit Easy manual unlocking Locked Lock unit length: A/26.5mm to 51.5mm Unlocked A (mm) 40 to 100 Bore size (mm) A Flat head screw driver 20 25 32 40 50 63 80 100 26.5 30.5 31.5 34 35 38 43 51.5 20 to 32 Body length Manual unlocking bolt Body length is the same as the standard MGP Locking direction is selectable Extension
Features 1 position within the entire stroke Low profile with compact lock unit Easy manual unlocking Locked Lock unit length: A/26.5mm to 51.5mm Unlocked A (mm) 40 to 100 Bore size (mm) A Flat head screw driver 20 25 32 40 50 63 80 100 26.5 30.5 31.5 34 35 38 43 51.5 20 to 32 Body length Manual unlocking bolt Body length is the same as the standard MGP Locking direction is selectable Extension