SMC Corporation of America
Elite Part Number Search
Search Results "MXP8-20C-M9NL"

(choked flow) Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the abbreviation (ANR) after the unit depicting air volume.

How to Calculate Flow (At an air temperature 20C) 1P1+0.1013<1.89(P2+0.1013) Q=226S P(P2+0.1013) Piping 2P1+0.10131.89(P2+0.1013) 1Completely flush (air blow) pipes before plumbing to remove dust. 2Clamping torgue: Q=113S(P1+0.1013) Q:Flow rate under standard conditions [ /min (ANR)] P1:Upstream pressure (MPa) P2:Downstream pressure(MPa) P:Pressure differential(P1-P2)(MPa) S:Effective area

(coil temperature 20C, at rated voltage, without surge voltage suppressor) When equipped with DC solenoid/surge voltage suppressor, a delay of about 20 to 30msec occurs in the OFF response time.

Port Solenoid Valve 3 Port Solenoid Valve Power Consumption (with power saving circuit) Temperature rise: 1C (with power saving circuit) V100 Specifications V100 Specifications V100 Specifications V100 Specifications Type With power saving circuit Standard Valves of specific power consumption can be manufactured to suit the f f f p f p p Power Consumption 0.1W 0.35W Temperature rise 1.0C 20C

(coil temperature 20C, at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states.

De-energized) Impact resistance 980 m/s2 in X, Y, Z directions 3 times each (De-energized) Port size M5 x 0.8 (Tightening torque: 1 to 1.5 Nm) Wetted parts material PPS, Si, Au, Stainless steel 316, C3604 (Electroless nickel plated) Lead wire Vinyl cabtire cord, 3 cores 2.6, 0.15 mm2, 2 m Mass 10 g (excluding lead wire) Note 1) Volume flow converted value under standard conditions (ANR) of 20C

(Inlet air pressure: 0.7 MPa, Inlet air temperature: 20C) HA How to Order AT ID 20 02 0 ID AMG ID400 Option B Bracket Z Adsorbent for low dew point Basic size AFF 20 30 40 60 Port size AM ID200 02 B 04 06 1 4 B 1 2 B 3 4 Nil Rc Thread type Misc.

. *2 10 to 500 Hz for 2 hours in each direction of X, Y, and Z (De-energized, Initial value) *3 3 times in each direction of X, Y, and Z (De-energized, Initial value) Weight Supply Valve/Release Valve Specifications *1 Based on JIS B 8419: 2010 dynamic performance test (Standard type: Coil temperature 20C, at rated voltage, without surge voltage suppressor) * Refer to the Web Catalog for

Air consumption Note 3) 18 L/min (ANR) or less (SUP = 0.5 MPa) Note 1) Specification values are given at normal temperature (20C). Note 2) Characteristics relating to accuracy differ depending on combination with other constituent loop equipment, such as positioners and actuators. Note 3) Air consumption is due to exhaust from nozzle. And (ANR) indicates JIS B0120 standard air.

Related Products Polyurethane Coil Tubing S Couplers Finger Valve Flexible Max. operating pressure: 0.8 MPa (at 20C) For moving applications * Colors other than black are available as made-to-order specifications. One-touch fitting type standardized (KK) Uses ultra high-impact PBT resin (KKH) The valve direction clearly indicates whether the valve is open or closed.

Minimum bending radius: Power supply cable30 mm (Note: Shown above is wiring with the fixed minimum allowable bending radius and at a temperature of 20C. If used under this temperature, the connector can receive excessive stress even though the minimum bending radius is allowable.)

Note 2) The above data is based on a room temperature of 20C. Note that you may obtain different figures, depending on temperature conditions. Note 3) The above data shows compatibility guidelines based upon component parts. Therefore, it is no guarantee of product performance.

Pressure spindle Stainless steel 303 POM, NBR, Stainless steel 303, Stainless steel 304 KN KN Sensing head (KNP) One-touch fittings Applicable tubing O.D. 4 Polyurethane Polyurethane tube (4, 1 m) Fluid Air KNP-2 Maximum operating pressure (at 20C) 0.8 MPa 5 to 60C (No freezing) Ambient and fluid temperature Pipe Stainless steel 304 POM, NBR, Stainless steel 304 One-touch fittings Polyurethane

Please contact SMC for further details. 2 Based on the JIS B 8419:2010 dynamic performance test (Coil temperature: 20C, pressure: 0.5 MPa, at the rated voltage) 3 Impact resistance: No malfunction occurred when it was tested in the axial direction and at a right angle to both the main valve and the armature in both an energized and de-energized state, once for each condition.

Port size Symbol Port size 10 R1 Specifications FND100V-10-M149X0 Model FND100N-10-M149X0 R1 Port size Bowl & Cover Stainless steel 304 O-ring Material NBR FKM Element Stainless steel 304 149 m Element nominal filtration rating Weight 7.5 kg Note) Produced upon receipt of order. 2 Series FN1/FN4 Flow Characteristics (Initial Value) P Test fluid: Potable water P Liquid temperature: 17 to 20C

4 15 1/4: 30 3/8: 40 Oil capacity [cm3] 7 25 55 135 Recommended lubricant Class 1 turbine oil (ISO VG32) Bowl material Polycarbonate Bowl guard Semi-standard (Steel) Standard (Polycarbonate) Weight [kg] 0.07 0.10 0.20 0.38 0.43 0.94 1.09 *1 The flow rate is 5 drops or greater/min under the following conditions: Inlet pressure of 0.5 MPa; Class 1 turbine oil (ISO VG32); Temperature at 20C

Heat generation amount Q : Unknown : 1.0C (1.0 K) : 20C (293.15 K) : 21C (294.15 K) : 7 L/min :Water : Density : 1 x 103 kg/m3 Circulating fluid temperature difference T (= T2 T1) Circulating fluid outlet temperature T1 Circulating fluid inlet temperature T2 Circulating fluid flow rate L Circulating fluid : Specific heat C: 4.2 x 103 J/(kgK) T1: Outlet temperature Q = T x L x x C 60 x 1000

(Inlet air pressure: 0.7 MPa, Inlet air temperature: 20C) Accessory (Option)/Replacement Parts Applicable model ID20 ID30 ID40 ID60 6604113 6604113 660651 660651 ID-200S ID-300S ID-400S ID-600S ID-200Z ID-300Z ID-400Z ID-600Z ID-DPM8 Bracket Adsorbent set Note) Adsorbent set (for low dew point) Note) Indicator set Note) Adsorbent and adsorption tube filter for one air dryer (two adsorption

.: 1/2 inch [Thread symbol: N], 12 mm [Thread symbol: Nil]) Drain tube holder, Operation manual Compliant standards UL, CSA Refrigerated air dryer Auto drain 1 The operating range does not guarantee use with normal air flow capacity. 2 Air flow capacity under the standard condition (ANR) [atmospheric pressure 68F (20C), relative humidity 65%] 3 When the operating conditions are different