Table Accuracy: Basic, Size: 50, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector

Table Accuracy: High Precision, Size: 10, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug

Table Accuracy: High Precision, Size: 30, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector

Table Accuracy: Basic, Size: 30, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 5, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Option: -, Communication Plug Connector or

Type: Fitting Body, Material: PFA, Connection Type: Pipe⇔Pipe, different diameters connection, Pipe-to-Pipe Unequal Diameter Connection Type: Reducing Union Tee, Applicable Tube Outer Dia. (in) D (D1): 1/4, Applicable Tube Outer Dia. (in) D2: 1/4, Applicable Tube Outer Dia. (in) D3: -, Maximum Operating Temperature(°C): 200, Packing: Clean Packaging Class M3.5 Equivalent, Nut Material: PFA

Type: Fitting Body, Material: PFA, Connection Type: Pipe⇔Pipe, different diameters connection, Pipe-to-Pipe Unequal Diameter Connection Type: Reducing Union Tee, Applicable Tube Outer Dia. (in) D (D1): 3/8, Applicable Tube Outer Dia. (in) D2: 3/8, Applicable Tube Outer Dia. (in) D3: 1/4, Maximum Operating Temperature(°C): 200, Packing: Clean Packaging Class M3.5 Equivalent, Nut Material:

Type: Fitting Body, Material: PFA, Connection Type: Pipe⇔Pipe, different diameters connection, Pipe-to-Pipe Unequal Diameter Connection Type: Reducing Union Tee, Applicable Tube Outer Dia. (in) D (D1): 1/2, Applicable Tube Outer Dia. (in) D2: 1/2, Applicable Tube Outer Dia. (in) D3: 3/8, Maximum Operating Temperature(°C): 200, Packing: Clean Packaging Class M3.5 Equivalent, Nut Material:

Type: Fitting Body, Material: PFA, Connection Type: Pipe⇔Pipe, different diameters connection, Pipe-to-Pipe Unequal Diameter Connection Type: Reducing Union Tee, Applicable Tube Outer Dia. (in) D (D1): 3/4, Applicable Tube Outer Dia. (in) D2: 3/4, Applicable Tube Outer Dia. (in) D3: 1/2, Maximum Operating Temperature(°C): 200, Packing: Clean Packaging Class M3.5 Equivalent, Nut Material:

Type: Fitting Body, Material: PFA, Connection Type: Pipe⇔Pipe, different diameters connection, Pipe-to-Pipe Unequal Diameter Connection Type: Reducing Union Tee, Applicable Tube Outer Dia. (in) D (D1): 1, Applicable Tube Outer Dia. (in) D2: -, Applicable Tube Outer Dia. (in) D3: 3/4, Maximum Operating Temperature(°C): 200, Packing: Clean Packaging Class M3.5 Equivalent, Nut Material: PFA,

Oscillation Angle A: 310°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: Standard, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 0.22, Size: 10, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Robotic (flexible) cable, Actuator cable length(

Oscillation Angle A: 310°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: Standard, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 0.32, Size: 10, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Robotic (flexible) cable, Actuator cable length(

Oscillation Angle A: 320°, Torque (Range)(N⋅m): 1 to Less than 3, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 1.2, Size: 30, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Robotic (flexible) cable

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Mounting: B (Basic Style), Bore Size: 63mm, Thread: TN (NPT), Stroke: 450mm, Stroke Adjustment: B (0 to 50), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC8 (Adjustable Stroke, Extension Type)

Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32, 8), Stroke: 450mm, Motor: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector